Description
Overview
This bundled product includes one TAVCI7H4R24 outdoor unit and one TAPEC7H4R24-4WS indoor unit for a single-zone system. Electrical supply is 208/230V, 60 Hz, 1-phase. The system uses R32 refrigerant and is designed for field piping between the indoor and outdoor sections. Model numbers are shown for procurement, matching, and service reference. Model numbers are shown for procurement, matching, and service reference.
Performance
Compressor design is Rotary in the outdoor section. Compressor manufacturer is Zhuhai Landa (Gree). Refrigerant metering method is Capillary. Outdoor unit moisture protection rating is IPX4. Outdoor fan airflow is rated at 1883 CFM.
Smart Features
The indoor unit provides multiple fan speed steps to balance airflow and sound based on room conditions. System operation supports standard cooling, heating, dry, and fan modes where available on the controller. For projects that require third-party controls, confirm compatibility with the specific indoor control interface before ordering.
Comfort & Noise
Outdoor sound pressure level is rated at 58 dB(A) at high fan setting. Use the fan speed steps to reduce indoor sound levels during occupied hours while maintaining temperature control. Swing motor operation supports directional airflow control where specified. Fan and coil design are specified to support consistent air delivery across typical room layouts. Fan and coil design are specified to support consistent air delivery across typical room layouts.
Use Case Fit
This product supports single-zone applications where one indoor unit serves one conditioned area. Published outdoor operating range supports Cooling -20~122°F, heating -22~86°F. Typical use cases include residential rooms, small offices, and similar spaces that benefit from zoned control. Select equipment voltage and capacity to align with the load and the available electrical service. Maximum line length is 131.2 ft with a maximum elevation difference of 82.0 ft.
Value & Reliability
Defrost method is Automatic Defrosting to maintain heating operation when outdoor conditions require coil clearing. Outdoor components use an axial-flow fan configuration where specified for heat rejection and air movement. Coil and fan assemblies are designed around aluminum fin and copper tube heat exchangers where specified. Use the listed component model numbers to streamline replacement parts selection and service planning. Routine service access focuses on airflow-side maintenance for the indoor section and refrigerant-side components for the outdoor section.
Summary Wrap-Up
Choose this Tosot Cardinal bundled system when you need a matched indoor and outdoor pairing for a single-zone project. Model-number clarity helps wholesalers, contractors, and direct buyers confirm what is included for ordering. Use the airflow and sound ranges to align the equipment with occupant comfort expectations and room layout. Confirm electrical service, piping limits, and control requirements before purchase to keep project planning aligned.
Key Features
- System components: Includes one TAVCI7H4R24 outdoor unit and one TAPEC7H4R24-4WS indoor unit for a single-zone configuration.
- Refrigerant type: Uses R32 refrigerant for split-system operation.
- Rotary compressor: Uses a rotary compressor design for refrigerant compression in the outdoor section.
- Electrical supply: Designed for 208/230V, 60 Hz, single-phase power.
- Piping limits: Supports up to 131.2 ft line length and 82.0 ft elevation difference within stated limits.