Description
Rheem 5 Ton Commercial Gas/Electric Package Unit (RGECYB060ADT072AAAA0)
The Rheem RGECYB060ADT072AAAA0 is a Commercial Classic Series packaged gas/electric rooftop unit in Rheem's small commercial (3-6 ton) cabinet. It combines R-454B air conditioning and a 75,000 BTU/h two-stage natural gas furnace in one cabinet, for buildings with 460 volt 3-phase service and gas on the roof: retail, offices, restaurants, schools, churches and light industrial space.
Cooling performance
- Nominal capacity: 5 ton (57,000 BTU/h AHRI net cooling)
- Efficiency: 13.4 SEER2, 10.6 EER2 (AHRI 210/240)
- Compressor: 1 scroll, single-stage; RLA 7.7, LRA 58.1
- Refrigerant: R-454B (A2L), factory charged, with a factory-installed refrigerant leak detection sensor
- Metering: TXV
- Sound rating: 86 dB (AHRI 270)
Gas heating
- Heating input: 75,000 high fire / 52,500 low fire BTU/h
- Heating output: 60,750 high fire / 42,525 low fire BTU/h
- Efficiency: 81% steady-state efficiency
- Gas valve: Two-stage
- Heat exchanger: Aluminized steel tubular, min. 20-ga steel with 1.2 mil aluminum-silicone coating
- Temperature rise: 30-60°F high fire / 20-50°F low fire
- Fuel: Natural gas as shipped. LP conversion kit RXGJ-FP40 (field-installed)
Airflow and cabinet
The cabinet converts between downflow (vertical) and horizontal duct connections in the field. The indoor blower is a direct-drive constant-torque motor, so airflow can be matched to the ductwork at startup.
- Nominal airflow: 2,000 CFM
- Indoor blower: 1 HP direct-drive constant-torque (frame 48, 1050 RPM), FLA 3.5
- Dimensions: 41-3/8 in H x 46-3/4 in W x 79-1/4 in D (base rail); cabinet top 44-5/8 x 77-7/8
- Operating weight: 586 lb
- Shipping weight: 624 lb
- Filters: (4) 2x16x16 in. disposable, furnished
- Controls: CoreCommand (non-communicating)
Electrical
- Power supply: 460V 3-Phase, 60 Hz (operating range 414-506 V)
- Minimum circuit ampacity: 15 A (17 A with power exhaust)
- Overcurrent protection: 20 A max overcurrent protection (20 A with power exhaust); min OCP 20 A (20 A with PE)
Accessories
Rheem field accessories for this cabinet include economizers, fresh air dampers, power exhaust and roof curbs (RXKG-DC14, RXKG-DC24, RXKG-DCC14, RXKG-DCC24, RXRD-01MCDBM3, RXRD-01MCHBM3, RXRD-11MCDAM3, RXRD-11MCHAM3, RXRD-31MCDAM3, RXRD-41MCDAM3, RXRD-41MCHAM3, RXRD-51MCDAM3, RXRD-51MCHAM3, RXRF-ACA1, RXRF-ACB1, RXRF-ACC1, RXRX-CCF02D, RXRX-CCF03D, RXRX-DCCAE, RXRX-RCF02D, RXRX-RCF03D). Match accessories by cabinet and airflow direction; see Rooftop Unit Accessories.
Warranty
Rheem limited warranty for commercial applications: 5-year compressor and 1-year parts, with a 10-year limited warranty on the heat exchanger. Full terms are in the Rheem warranty document for this series.
White Paper
- Rheem RGECYB Spec Sheet (Part 1)
- Rheem RGECYB Spec Sheet (Part 2)
- Rheem RGECYB Spec Sheet (Part 3)
- Rheem RGECYB Spec Sheet (Part 4)
- Rheem RGECYB Spec Sheet (Part 5)
- Rheem RGECYB Spec Sheet (Part 6)
- Rheem RGECYB Spec Sheet (Part 7)
- Rheem RGECYB Installation Manual (Part 1)
- Rheem RGECYB Installation Manual (Part 2)
- Rheem RGECYB Installation Manual (Part 3)
- Rheem RGECYB Installation Manual (Part 4)
- Rheem RGECYB Installation Manual (Part 5)
- Rheem RGECYB Installation Manual (Part 6)
- Rheem RGECYB Installation Manual (Part 7)
- Rheem RGECYB Installation Manual (Part 8)
- Rheem RGECYB Installation Manual (Part 9)
- Rheem RGECYB Installation Manual (Part 10)
- Rheem RGECYB Installation Manual (Part 11)
- Rheem RGECYB Installation Manual (Part 12)
- Rheem RGECYB Installation Manual (Part 13)
- Rheem RGECYB Installation Manual (Part 14)
- Rheem RGECYB Warranty