Medium-temperature condensing units power the coolers that hold fresh product: walk-in coolers, beer and beverage boxes, floral coolers, prep rooms and refrigerated display cases. They are designed to run at the suction temperatures needed to keep a space around 35°F to 40°F, typically in the range of 15°F to 25°F saturated suction.

This category includes air-cooled medium-temperature units from Bohn, Copeland and Kramer, with scroll and hermetic reciprocating compressors, preconfigured options with factory-installed accessories, and single-phase or three-phase power across a wide span of capacities.

Choosing the Right Medium Temp Condensing Unit

Start with the box load in BTU/h. Box size, insulation, door traffic, product loading and the temperature around the box all feed into that number. Then choose a unit whose rated capacity at your suction temperature and ambient conditions covers the load with sensible run-time margin, usually about 16 hours of run time per day for a cooler.

The unit cooler matters just as much. Capacity, refrigerant and defrost method must line up between the two. Most coolers use off-cycle defrost, so the condensing unit simply cycles off and lets the coil clear.

Buying Tips

  • Check the ambient. Capacity drops as outdoor temperature rises. Units on hot roofs need extra margin.
  • Confirm voltage and phase. Many sizes come in both single-phase and three-phase versions.
  • Compare included accessories. Receivers, pressure controls, sight glasses and low-ambient kits vary by listing.
  • Plan for winter. In cold climates, head pressure control keeps the system stable when outdoor temperatures drop.

Common Applications

Walk-in coolers for restaurants and grocers, beverage and beer coolers, produce and floral rooms, refrigerated prep areas and remote display cases. For a new walk-in, our matched walk-in cooler systems pair the condensing unit with the correct unit cooler for each box size.

What It Takes to Install

A licensed, EPA Section 608 certified refrigeration contractor should install the unit. That includes setting it with proper clearance, brazing and pressure testing the lines, evacuating and charging the system, and verifying superheat, subcooling and box temperature at startup.

Things You Should Know Before You Buy

Codes and refrigerant rules vary by state and region. Confirm requirements with your contractor or local building department before choosing equipment and refrigerant.

Frequently Asked Questions

Q: What box temperature can a medium temp condensing unit hold?

A: Medium-temperature units are designed for spaces around 35°F to 40°F, such as walk-in coolers and display cases.

Q: Can I use a medium temp unit for a freezer?

A: No. Freezers need low-temperature equipment built to run at much lower suction pressures.

Q: How much run time should a cooler system have?

A: Cooler systems are commonly sized for about 16 hours of run time per day, leaving off-cycle time for the coil to defrost.

Q: Do these units include the evaporator?

A: No. These are condensing units only. Shop our unit coolers or our matched walk-in cooler systems for the indoor side.