This category covers two kinds of unit-level protection that commercial packaged units often need and that are easy to leave off an order: duct smoke detection, which shuts the unit's fan down so it does not spread smoke through the building, and indoor coil freeze protection, which keeps a lightly loaded unit from icing its own coil. Both are life-safety or equipment-protection items, both are inspected or noticed when they are missing, and both are much easier to install before the unit is in service.
| Part | Function | Unit fit |
|---|---|---|
| Rheem RXRX-BS01 | Return air duct smoke detector, field kit | C cabinet: RACCYB 3-5 ton, RGECYB and RHPCYB 3-6 ton |
| Rheem RXRX-BS02 | Return and supply air duct smoke detector, field kit | C cabinet, 3-6 ton |
| Rheem RXRX-BS03 | Communicating return air smoke detector kit | D cabinet: RACDYB and RGEDYB 7.5-12.5 ton, RHPDYB 7.5-10 ton |
| Rheem RXRX-BS04 | Return and supply air smoke detector kit | D cabinet, same units as above |
| Daikin FSK02A | Freeze protection thermostat kit | Daikin packaged rooftop units listed on the product page |
| Daikin FSK03A | Freeze protection thermostat kit | Daikin packaged rooftop units listed on the product page |
Other controls live with the equipment they serve. Economizer controllers, enthalpy sensors and the Daikin CO2 sensor are under Rooftop Unit Economizers. The FSK04A freeze protection kit for 7.5 to 10 ton Daikin units is under Blower, Vent and Conversion Kits. DDC versions of dampers and power exhaust are in their own categories.
Most US jurisdictions adopt the International Mechanical Code, which requires smoke detectors in the return air of air distribution systems above 2,000 CFM, with listed exceptions and additional requirements for some configurations. Many jurisdictions amend the model code, so the authority having jurisdiction and the project drawings have the final word. In practical terms:
Start with the cabinet. The BS01 and BS02 kits fit the C cabinet; BS03 and BS04 fit the D cabinet. Then decide return-only or return-and-supply based on the code analysis. For D-cabinet units, the BS03 is listed as a communicating return detector kit, intended for units using Rheem's communicating controls; confirm with the unit's control documentation that it matches your board before ordering. These unit-mounted kits install in the unit's return and, where applicable, supply sections, which saves field duct work and keeps the detectors where the service technician can reach them.
Duct detectors are inspected and tested periodically under the fire code and the detector manufacturer's instructions. Dust buildup in the detector or its sampling path causes nuisance alarms, and a failed detector is a code violation found at the next fire inspection. Include the detectors in the unit's planned maintenance, keep the test records with the building's fire and life safety documentation, and never leave a detector bypassed after service.
An indoor coil freezes when its surface temperature stays below 32 degrees long enough for condensate to turn to ice. On commercial packaged units, the usual causes are:
Ice blocks airflow, cuts capacity, and when it melts it can overflow the drain pan into the ceiling below. Repeated freezing also risks liquid refrigerant reaching the compressor.
The FSK02A and FSK03A kits protect the indoor coil from freezing during low-load cooling operation on the Daikin packaged units listed on each product page. A freeze protection thermostat of this kind senses coil temperature and interrupts cooling when the coil gets too cold, letting it recover before cooling resumes. Check the product page and the unit accessory table to pick the kit listed for your unit. For 7.5 to 10 ton units, the FSK04A kit is listed under Blower, Vent and Conversion Kits.
A freeze protection kit is protection, not a cure. If a unit trips it regularly, find the cause: check airflow, filters, belts, refrigerant charge, economizer minimum position and the control sequence.
On a unit with an economizer, smoke detector shutdown should also leave the outdoor air and relief dampers in the position the code and fire protection design call for, which on most packaged units means the dampers return to their closed or minimum position when the fan stops. Confirm the sequence during the detector test.
It depends on its design airflow and local code. Under the International Mechanical Code threshold of 2,000 CFM, a 5 ton unit is borderline. Use the scheduled airflow and check with the code official.
Return air detection is the common requirement. Supply detection is added for certain configurations or when the designer or code official calls for it.
Yes, and where a fire alarm system exists it is usually required. Coordinate the connection with the fire alarm contractor.
It shuts down the unit's supply fan so the system does not distribute smoke. The unit stays off until the detector is reset.
Usually not. Repeated trips point to low airflow, low charge, low load or too much cold outdoor air. Diagnose the unit before replacing the kit.
Yes, these are field-installed kits. Schedule a test with the fire alarm contractor if the building has a monitored system.