null

Cooper & Hunter One-Way Cassette 6,000 BTU 0.5 Ton 22 SEER2 One-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V | CH-RHP06F9-230VO-CH-RSH06-12MCT1W

Cooper & Hunter

Local HVAC Offers

Special pricing available — add to cart or call for details.
Limited-time availability.
About this promotion
Cyber Weekend Sales Event

No reviews yet Write a Review
SKU:
CH-RHP06F9-230VO-CH-RSH06-12MCT1W
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New

Questions about Cooper & Hunter One-Way Cassette 6,000 BTU 0.5 Ton 22 SEER2 One-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V | CH-RHP06F9-230VO-CH-RSH06-12MCT1W?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

At a glance

Fast Shipping

Customer Support

Warranty Coverage

Financing Avaliable

$4,744.44

10 in stock • Ships in 3-5 Business Days

Description

The Cooper & Hunter One-Way Cassette 6,000 BTU one-way ceiling cassette system pairs the CH-RHP06F9-230VO outdoor heat pump with the CH-RSH06-12MCT1W indoor unit as an AHRI-matched single-zone ductless mini split (AHRI #215864251). It is rated at 22 SEER2 on R-454B refrigerant and runs on 208/230V single-phase power, heating and cooling one room or zone without ductwork.

The One-Way Cassette is a slim linear cassette that recesses into the ceiling and throws air in one direction, ideal along a wall or in narrow rooms and hallways. The decorative panel, refrigerant detection sensor (RDS) and humidity sensor are included. The 6-12K model is set to 6K, 9K or 12K by dip switch.

What's Included

  • 1 × CH-RHP06F9-230VO Cooper & Hunter outdoor heat pump condenser
  • 1 × CH-RSH06-12MCT1W One-Way Cassette one-way ceiling cassette indoor unit
  • 1 × wireless remote control
  • Smart Kit (Wi-Fi, Cooper & Hunter app)

System Performance

  • AHRI Reference Number: 215864251
  • Nominal Capacity: 6,000 BTU/h (0.5 ton)
  • SEER2: 22
  • HSPF2 (Region IV): 14.8
  • Heating Capacity @ 47°F: 7,000 (3,000~11,000)
  • Refrigerant: R-454B
  • Power Supply: 208/230V 1-Phase 60 Hz
  • Outdoor Unit Type: Hyper Heat (heats down to -22°F)

Component Specifications

Outdoor Unit — CH-RHP06F9-230VO

  • Model: CH-RHP06F9-230VO
  • Cooling Capacity, rated (min~max) BTU/h: 6,000 (2,300~12,600)
  • Heating Capacity, rated (min~max) BTU/h: 7,000 (3,000~11,000)
  • COP @ 47°F: 4.2
  • HSPF2 (Region IV / V): 14.8 / 11.5
  • Refrigerant Piping (Liquid/Gas): 1/4"/3/8"
  • Max Line Length (ft): 82
  • Max Height Difference (ft): 49.2
  • Minimum Circuit Ampacity (A): 12
  • Max Fuse / Breaker (A): 15
  • Outdoor Sound Level (dB(A)): 53
  • Cooling Operating Range (°F outdoor): -22~122
  • Heating Operating Range (°F outdoor): -22~75
  • Unit Dimensions (W x D x H): 30.12 in x 11.93 in x 21.85 in
  • Net / Shipping Weight: 62.17 lb / 67.68 lb

Indoor Unit — CH-RSH06-12MCT1W

  • Model: CH-RSH06-12MCT1W
  • Cooling Capacity (BTU/h): 6,000/9,000/12,000
  • Refrigerant Piping (Liquid/Gas): 1/4"/3/8"
  • Airflow (CFM, high to low): 353.2 / 312 / 282.5 / 247.2
  • Sound Level (dB(A), high/med/low): 41/37/33
  • Condensate Drain: 3/4"
  • Unit Dimensions (W x D x H): 50.31 in x 13.19 in x 8.98 in
  • Net / Shipping Weight: 45.19 lb / 82.45 lb

Installation Notes

Mini split heat pumps must be installed by a licensed HVAC technician: the line set is flared, pressure tested, evacuated and charge-adjusted on site. R-454B is a mildly flammable (A2L) refrigerant, so A2L-rated tools and the manufacturer's procedures are required. Size the unit from a room load calculation rather than square footage alone. Each outdoor unit needs its own dedicated circuit sized to the rating plate (12 A MCA, 15 A max fuse).

White Paper

Common Questions

Does this system come with a line set?

No. The line set, communication wire, wall sleeve, condensate line and mounting hardware are sold separately.

Can this outdoor unit run more than one indoor unit?

No. This is a single-zone (one outdoor to one indoor) system. Cooper & Hunter multi-zone condensers are listed separately.

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Cooper & Hunter
Weight:
150.10 LBS
Prop 65 Warning:
Yes
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Category:
Ductless Mini Split Single Zone
Series:
One-Way Cassette
System Type:
Heat Pump
Zones:
1
Configuration:
Ceiling Cassette
Mount Type:
Ceiling Cassette
Indoor Air Handler Type(s):
One-Way Ceiling Cassette
Capacity (Tons):
0.5
Cooling Capacity (BTU):
6,000
SEER2:
22 SEER2
AHRI Certified:
Yes
AHRI Reference Number:
215864251
Refrigerant Type:
R-454B
Compressor Type:
Inverter
Connection Type:
Flare Fittings
Voltage / Phase:
208/230V 1-Phase
Electrical Phase:
1-Phase
Cold Climate:
Yes
Minimum Heating Temp (°F):
-22
Outdoor Unit Model:
CH-RHP06F9-230VO
Indoor Unit Model:
CH-RSH06-12MCT1W
HSPF2:
14.8 HSPF2
Breaker Size (Amps):
15
Outdoor Unit CH-RHP06F9-230VO - Cooling Capacity, rated (min~max) BTU/h:
6,000 (2,300~12,600)
Outdoor Unit CH-RHP06F9-230VO - Heating Capacity, rated (min~max) BTU/h:
7,000 (3,000~11,000)
Outdoor Unit CH-RHP06F9-230VO - COP @ 47°F:
4.2
Outdoor Unit CH-RHP06F9-230VO - HSPF2 (Region IV / V):
14.8 / 11.5
Outdoor Unit CH-RHP06F9-230VO - Refrigerant Piping (Liquid/Gas):
1/4"/3/8"
Outdoor Unit CH-RHP06F9-230VO - Max Line Length (ft):
82
Outdoor Unit CH-RHP06F9-230VO - Max Height Difference (ft):
49.2
Outdoor Unit CH-RHP06F9-230VO - Minimum Circuit Ampacity (A):
12
Outdoor Unit CH-RHP06F9-230VO - Max Fuse / Breaker (A):
15
Outdoor Unit CH-RHP06F9-230VO - Outdoor Sound Level (dB(A)):
53
Outdoor Unit CH-RHP06F9-230VO - Cooling Operating Range (°F outdoor):
-22~122
Outdoor Unit CH-RHP06F9-230VO - Heating Operating Range (°F outdoor):
-22~75
Outdoor Unit CH-RHP06F9-230VO - Unit Dimensions (W x D x H):
30.12 in x 11.93 in x 21.85 in
Outdoor Unit CH-RHP06F9-230VO - Net / Shipping Weight:
62.17 lb / 67.68 lb
Indoor Unit CH-RSH06-12MCT1W - Cooling Capacity (BTU/h):
6,000/9,000/12,000
Indoor Unit CH-RSH06-12MCT1W - Refrigerant Piping (Liquid/Gas):
1/4"/3/8"
Indoor Unit CH-RSH06-12MCT1W - Airflow (CFM, high to low):
353.2 / 312 / 282.5 / 247.2
Indoor Unit CH-RSH06-12MCT1W - Sound Level (dB(A), high/med/low):
41/37/33
Indoor Unit CH-RSH06-12MCT1W - Condensate Drain:
3/4"
Indoor Unit CH-RSH06-12MCT1W - Unit Dimensions (W x D x H):
50.31 in x 13.19 in x 8.98 in
Indoor Unit CH-RSH06-12MCT1W - Net / Shipping Weight:
45.19 lb / 82.45 lb
Heating Capacity (BTU):
7,000
EER2:
13 EER2
Sound Level Indoor (dB):
33
Sound Level Outdoor (dB):
53
Liquid Line Size | OD - Outside Diameter:
1
Suction Line Size | OD - Outside Diameter:
4"
Minimum Circuit Ampacity (MCA):
12
Maximum Overcurrent Protection (MOP):
15
Max Line Length (ft):
82
Shipping Weight:
150.1 lb

Warranty Information

7 Years Compressor & 5 Years Parts | Registration Required within 60 Days of Installation

Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document


Fast Shipping

Easy Returns

Warranty Coverage

Financing Available