Description
Product Summary
The Daikin DC6TE09040 is a 7.5-ton R-32 commercial split-system air conditioner condensing unit from the Daikin DC6TE0 series, built for 460V 3-Phase light commercial power. It delivers a rated 95,000 BTU/h of cooling.
It is rated at 16.4 IEER and 12.3 EER, with a two-stage compressor and factory-applied R-32 charge.
Contractors use the DC6TE09040 to pair with a matched Daikin R-32 commercial air handler or coil on offices, retail spaces and other light commercial buildings that need three-phase split-system cooling.
Key Features
- R-32 refrigerant: lower global warming potential refrigerant used across the current Daikin commercial split lineup
- Two-stage operation: two-stage compressor system for better part-load efficiency, reflected in the 16+ IEER rating
- Commercial three-phase power: 460V 3-Phase supply with 17.9 A MCA and 20 A MOP
- Large line connections: 1-1/8 in suction and 5/8 in liquid connections
- Heavy-duty cabinet: 41.5 x 35.5 x 35.5 in footprint for rooftop or slab mounting
Specifications
| Model Number | DC6TE09040 |
|---|---|
| Series | Daikin DC6TE0 (R-32) |
| Nominal Capacity | 7.5 Tons |
| Rated Cooling Capacity | 95,000 BTU/h |
| EER | 12.3 |
| IEER | 16.4 |
| Power Supply | 460V 3-Phase, 60 Hz |
| Minimum Circuit Ampacity (MCA) | 17.9 A |
| Maximum Overcurrent Protection (MOP) | 20 A |
| Compressor | Two-stage |
| Refrigerant | R-32 |
| Holding Charge | 110 oz |
| Suction Line Connection | 1-1/8 in |
| Liquid Line Connection | 5/8 in |
| Unit Dimensions (H x W x D) | 41.5 x 35.5 x 35.5 in |
| Net Weight | 350 lb |
| Shipping Weight | 392 lb |
Ideal Applications
- Offices and professional buildings
- Retail stores and strip centers
- Restaurants and light commercial kitchens (dining areas)
- Schools, churches and community buildings
- Light commercial retrofits replacing R-410A split systems
Frequently Asked Questions
What refrigerant does the Daikin DC6TE09040 use?
The DC6TE09040 uses R-32 refrigerant and ships with a 110 oz holding charge. Pair it only with R-32 rated indoor equipment.
What power supply does the DC6TE09040 need?
It requires 460V 3-Phase, 60 Hz power. The published minimum circuit ampacity is 17.9 A and the maximum overcurrent protection is 20 A.
What size line set does the DC6TE09040 use?
The unit has a 1-1/8 in suction connection and a 5/8 in liquid connection.
What indoor unit should I match with the DC6TE09040?
Use a Daikin R-32 commercial air handler or coil matched to 7.5 tons in the AHRI directory. Contact HVAC365 and we will help confirm the matched system.