Description
The Goodman 2.5 Ton 17.5 SEER2 8.5 HSPF2 80% AFUE 80,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 (GZV6SA3010 / GRVT800804CX / CHPEA3026C3) is a complete dual fuel heating and cooling system that pairs an electric heat pump with a gas furnace. This AHRI-matched system combines a 2.5-ton R-32 heat pump, 80% AFUE two-stage gas furnace, and cased evaporator coil so the heat pump handles cooling and mild-weather heating, while the furnace takes over when outdoor temperatures drop.
Designed for upflow installation, the system uses the furnace's variable-speed ECM blower motor to move air for both the heat pump and the gas burners. With a dual-fuel thermostat or outdoor temperature control, the system switches to gas heat below a set balance point, which keeps homes comfortable in cold snaps and lets you choose the more economical fuel for your local utility rates.
Key Features
-
2.5 Ton Cooling Capacity – AHRI-rated 28,400 BTU/h of cooling
-
17.5 SEER2 / 10 EER2 – Certified matched-system cooling efficiency
-
8.5 HSPF2 Heat Pump Heating – 28,800 BTU/h at 47°F and 18,000 BTU/h at 17°F
-
80,000 BTU Gas Furnace – Two-stage heating with 80% AFUE efficiency
-
Dual Fuel Operation – Heat pump for efficient mild-weather heat, gas furnace for cold-weather backup
-
Upflow R-32 System – Uses lower-GWP R-32 refrigerant
System Components Included
-
Goodman GZV6SA3010 2.5 Ton R-32 Heat Pump
-
Goodman GRVT800804CX 80,000 BTU 80% AFUE Two-Stage Gas Furnace
-
Goodman CHPEA3026C3 Cased Horizontal R-32 Evaporator Coil
Compatibility & Installation Notes
The GZV6SA3010 / GRVT800804CX / CHPEA3026C3 system is AHRI certified under reference number 215447170 and is designed for residential upflow applications. Compatibility with the property's ductwork, electrical service, gas supply, refrigerant lines, condensate drainage, and furnace venting must be confirmed before installation. The communicating GZV6SA3010 heat pump and GRVT800804CX furnace connect over the two communication wires, and the furnace control manages dual fuel switchover on its own, so a standard single-stage 24 VAC thermostat is all you need. No separate dual fuel kit is required.
Specifications
-
System Type: Hybrid Dual Fuel Heat Pump & Gas Furnace Split System
-
AHRI Reference Number: 215447170
-
Cooling Capacity: 28,400 BTU/h
-
Heat Pump Heating Capacity: 28,800 BTU/h at 47°F / 18,000 BTU/h at 17°F
-
Cooling Efficiency: 17.5 SEER2 / 10 EER2
-
Heating Efficiency: 8.5 HSPF2
-
Furnace Input / Output: 80,000 / 64,000 BTU/h
-
Furnace Efficiency: 80% AFUE
-
Refrigerant / Orientation: R-32 / Upflow
Installation Notes
-
Verify compatibility with the existing upflow ductwork
-
Confirm electrical service and natural gas connection requirements
-
Check the required refrigerant line sizes before installation
-
Ensure proper metal flue venting (Category I) for the 80% AFUE furnace
-
Connect the 1 and 2 communication wires between the furnace and heat pump and set up the thermostat for single-stage AC and single-stage gas heat
-
Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What is included in this Goodman HVAC system?
The package includes the GZV6SA3010 heat pump, GRVT800804CX gas furnace, and CHPEA3026C3 cased evaporator coil.
How does a dual fuel system work?
The heat pump cools in summer and heats in mild weather. When the outdoor temperature falls below the balance point set on the thermostat, the gas furnace takes over heating, so the system always runs on the more effective heat source.
What is the heating rating of the heat pump?
This matched system is rated at 8.5 HSPF2, with 28,800 BTU/h of heat pump heating at 47°F.
What is the cooling capacity of this system?
The system provides 2.5 tons with an AHRI-rated 28,400 BTU/h of cooling.
Is the furnace single-stage or two-stage?
The Goodman GRVT800804CX is a two-stage gas furnace.
What does 80% AFUE mean?
It means approximately 80% of the furnace's fuel is converted into usable heating energy.
Does this system use R-32 refrigerant?
Yes. The heat pump and evaporator coil are designed for R-32 refrigerant.
White Paper