Goodman 2 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA2410 GR9T800804BX CHPTA3026B3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA2410-GR9T800804BX-CHPTA3026B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
48.00 (in)
Height:
40.00 (in)
Depth:
40.00 (in)

Questions about Goodman 2 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA2410 GR9T800804BX CHPTA3026B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$4,493.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 2 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA2410 GR9T800804BX CHPTA3026B3

Goodman 2 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32, model GLXS4BA2410 GR9T800804BX CHPTA3026B3 - view 5
Product details

Description

The Goodman GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is a 2-ton, 15.2 SEER2 gas-electric split system built for homes that need both air conditioning and gas heat in a single matched bundle. If you've been piecing together a system from separate components — condenser, coil, and furnace — this bundle solves that in one order. Running R-32 refrigerant and an 80,000 BTU furnace at 80% AFUE, it delivers solid efficiency and real heating capacity without overshooting the budget. AHRI certified, nationwide eligible (except California), and configured horizontally, it's designed for attic or crawlspace installs where vertical clearance is tight.

Key Features

  • 15.2 SEER2 Efficiency: Meets current federal efficiency standards and keeps summer cooling bills in check without stepping up to premium pricing.
  • R-32 Refrigerant: R-32 has a lower global warming potential than R-410A and is the refrigerant direction the industry is moving — this system is ready for that shift.
  • 80,000 BTU Gas Furnace at 80% AFUE: Delivers enough heating capacity for a mid-size home while consuming 80 cents of every dollar of gas as usable heat.
  • Horizontal Configuration: Designed specifically for horizontal airflow applications — attics, crawlspaces, and tight utility rooms where a standard upflow furnace won't fit.
  • AHRI Certified Matched System: The condenser, coil, and furnace are rated and certified together, so the efficiency numbers on paper reflect what the system actually delivers in the field.
  • 1,600 CFM Airflow: Moves enough air for a properly sized 2-ton load without straining ductwork designed for that range.

Is this the right unit for your project?

A 2-ton system is typically right for living spaces in the 900–1,300 square foot range, though the real number depends on ceiling height, insulation, window area, climate zone, and infiltration — a Manual J calculation confirms actual load. Don't oversize: a unit too large for the space short-cycles, fails to dehumidify properly, and wears out faster. The horizontal configuration makes this bundle a fit for attic-mounted or side-discharge applications, not standard upflow closet installs.

Matched bundle vs. buying components separately

Buying a condenser, coil, and furnace separately lets you mix brands and match configurations, but you carry the burden of confirming AHRI compatibility across components. This bundle ships as a pre-matched set — the GLXS4BA2410-GR9T800804BX-CHPTA3026B3 has been rated together, so you're not chasing AHRI numbers across three separate spec sheets. For most standard horizontal residential installs, the bundle approach saves time and eliminates a common source of installation error. If you have an unusual duct layout or need a higher AFUE furnace, buying separately may make more sense.

Where it fits best

  • Attic-mounted horizontal systems in single-story homes
  • Crawlspace installations where the air handler sits on its side
  • Replacement systems in homes already plumbed for natural gas
  • New construction builds in climates that need both dedicated gas heat and central cooling
  • Mobile or manufactured homes with horizontal furnace configurations (verify manufacturer approval)

Why R-32 matters for this install

R-32 is replacing R-410A across much of the HVAC industry because it has roughly one-third the global warming potential. It also runs at slightly higher pressures, which means recovery equipment and technician certification matter — any EPA 608-certified tech can handle it, but it's worth confirming your gauges and recovery machine are rated for R-32 before the install day. On the supply side, R-32 equipment is increasingly available and priced competitively, so choosing it now doesn't mean paying a premium for forward-looking refrigerant compliance.

Installation & what else you’ll need

This system runs on single-phase, 208–230V, 60Hz power — standard residential service in most markets. The horizontal configuration means the furnace and coil mount in a non-standard orientation, so verify your existing duct connections and drain pan setup before ordering. You'll need a disconnect whip sized for the condenser, a concrete pad or pre-formed equipment pad for the outdoor unit, a compatible communicating or conventional thermostat, and proper refrigerant line sets sized for R-32. Refrigerant handling requires EPA 608 certification. Gas connections to the furnace require a licensed gas fitter or HVAC contractor in most jurisdictions. Not available for sale or shipment to California.

Frequently Asked Questions

How many tons is the Goodman GLXS4BA2410-GR9T800804BX-CHPTA3026B3?

The GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is a 2-ton system, rated at 24,000 BTU of cooling capacity. That makes it appropriate for smaller to mid-size homes, typically in the 900–1,300 square foot range depending on insulation, climate, and load — confirm with a Manual J before ordering.

What SEER2 rating does this Goodman gas-electric split system have?

This Goodman bundle is rated at 15.2 SEER2 and 12 EER2. These are the current federal efficiency metrics replacing legacy SEER ratings. The system is AHRI certified as a matched set, so those numbers reflect actual combined performance of the condenser, coil, and furnace together.

What refrigerant does the GLXS4BA2410 condenser use?

The GLXS4BA2410 condenser uses R-32 refrigerant. R-32 has a lower global warming potential than R-410A. Handling requires EPA 608 certification, and you should confirm your recovery equipment is rated for R-32 before the install.

Is this Goodman split system available in California?

No. The GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is available nationwide except California. California has its own refrigerant and efficiency regulations that this system does not currently meet for sale or installation in that state.

What does horizontal configuration mean for a gas furnace split system?

Horizontal configuration means the furnace is designed to lie on its side with airflow moving sideways rather than straight up. This is required for attic or crawlspace installs where a standard upflow furnace won't fit. The coil and ductwork connections are oriented accordingly — it is not interchangeable with an upflow setup without modification.

Does this Goodman bundle include the coil and furnace, or just the condenser?

This bundle includes all three components: the GLXS4BA2410 condenser, the GR9T800804BX gas furnace, and the CHPTA3026B3 horizontal coil. They ship as a pre-matched, AHRI-certified set. You still need line sets, a thermostat, electrical whip, and gas connection completed by a licensed installer.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
48.00 (in)
Height:
40.00 (in)
Depth:
40.00 (in)
Weight:
383.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Electrical Phase:
1-Phase
Configuration:
Horizontal
Airflow (CFM):
1,600
SEER2:
15 SEER2
Electrical Frequency:
60 Hz
AFUE:
80%
Refrigerant Type:
R-32
Product Category:
Gas Heating & Air Conditioner Bundle
AHRI Certified:
Yes
Capacity (Tons):
2
EER2:
12 EER2
Unit Weight:
282 lb
Line Set Connection Type:
Braze
Liquid Line Size:
3/8 in
Prop 65 Warning:
Yes
Shipping Weight:
312 lb
Heating Input (BTU):
70,000 - 99,000 BTU
Vent Type:
Chimney / Category I
Blower Motor Type:
ECM Constant Torque
AHRI Reference Number:
215214739
Color:
Gray
Heating Stages:
Two Stage
Cabinet Width (in):
17.5
Cooling Capacity (BTU):
24,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA2410 - Nominal Capacity (Tons):
2
Condenser GLXS4BA2410 - Cooling Capacity (BTU/h):
24,000
Condenser GLXS4BA2410 - Refrigerant:
R-32
Condenser GLXS4BA2410 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA2410 - Minimum Circuit Ampacity (MCA):
10.9 A
Condenser GLXS4BA2410 - Maximum Overcurrent Protection (MOP):
15 A
Condenser GLXS4BA2410 - Compressor Type:
Rotary
Condenser GLXS4BA2410 - Compressor Stages:
Single Stage
Condenser GLXS4BA2410 - Liquid Line Size:
3/8 in
Condenser GLXS4BA2410 - Suction Line Size:
3/4 in
Condenser GLXS4BA2410 - Sound Level (dB):
74
Condenser GLXS4BA2410 - Unit Dimensions (W x D x H):
26 in x 26 in x 27 in
Condenser GLXS4BA2410 - Unit Weight:
117 lb
Condenser GLXS4BA2410 - Shipping Weight:
132 lb
Furnace GR9T800804BX - Input (BTU/h):
80,000
Furnace GR9T800804BX - Output (BTU/h):
64,000
Furnace GR9T800804BX - AFUE:
80%
Furnace GR9T800804BX - Heating Stages:
Two Stage
Furnace GR9T800804BX - Blower Motor Type:
ECM Constant Torque
Furnace GR9T800804BX - Maximum Cooling Capacity (Tons):
5
Furnace GR9T800804BX - Configuration:
Upflow/Horizontal
Furnace GR9T800804BX - Cabinet Width:
17.5 in
Furnace GR9T800804BX - Vent Type:
Chimney / Category I
Furnace GR9T800804BX - Gas Type:
Propane Convertible
Furnace GR9T800804BX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GR9T800804BX - Unit Dimensions (W x D x H):
17.5 in x 28 in x 33.375 in
Furnace GR9T800804BX - Shipping Weight:
121 lb
Evaporator Coil CHPTA3026B3 - Nominal Capacity (Tons):
2.5
Evaporator Coil CHPTA3026B3 - Cased/Uncased:
Cased
Evaporator Coil CHPTA3026B3 - Configuration:
Horizontal
Evaporator Coil CHPTA3026B3 - Cabinet Width:
26 in
Evaporator Coil CHPTA3026B3 - Metering Device:
TXV
Evaporator Coil CHPTA3026B3 - Refrigerant:
R-32
Evaporator Coil CHPTA3026B3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPTA3026B3 - Suction Line Size:
3/4 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What is the SEER2 rating of the ?
The is rated at 15 SEER2 SEER2.
What is the AFUE of the ?
The is rated at 80% AFUE.
What refrigerant does the use?
It uses R-32 refrigerant.
What size is the ?
The is a 2 ton unit.
What is the heating input of the ?
The heating input is 70,000 - 99,000 BTU BTU.
Is the AHRI certified?
Yes. The AHRI reference number is 215214739.
How much cooling does the provide?
It is rated for 24,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA2410-GR9T800804BX-CHPTA3026B3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA2410-GR9T800804BX-CHPTA3026B3?
The GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is made by Goodman.