Description
The Goodman GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is a 2-ton, 15.2 SEER2 gas-electric split system built for homes that need both air conditioning and gas heat in a single matched bundle. If you've been piecing together a system from separate components — condenser, coil, and furnace — this bundle solves that in one order. Running R-32 refrigerant and an 80,000 BTU furnace at 80% AFUE, it delivers solid efficiency and real heating capacity without overshooting the budget. AHRI certified, nationwide eligible (except California), and configured horizontally, it's designed for attic or crawlspace installs where vertical clearance is tight.
Key Features
- 15.2 SEER2 Efficiency: Meets current federal efficiency standards and keeps summer cooling bills in check without stepping up to premium pricing.
- R-32 Refrigerant: R-32 has a lower global warming potential than R-410A and is the refrigerant direction the industry is moving — this system is ready for that shift.
- 80,000 BTU Gas Furnace at 80% AFUE: Delivers enough heating capacity for a mid-size home while consuming 80 cents of every dollar of gas as usable heat.
- Horizontal Configuration: Designed specifically for horizontal airflow applications — attics, crawlspaces, and tight utility rooms where a standard upflow furnace won't fit.
- AHRI Certified Matched System: The condenser, coil, and furnace are rated and certified together, so the efficiency numbers on paper reflect what the system actually delivers in the field.
- 1,600 CFM Airflow: Moves enough air for a properly sized 2-ton load without straining ductwork designed for that range.
Is this the right unit for your project?
A 2-ton system is typically right for living spaces in the 900–1,300 square foot range, though the real number depends on ceiling height, insulation, window area, climate zone, and infiltration — a Manual J calculation confirms actual load. Don't oversize: a unit too large for the space short-cycles, fails to dehumidify properly, and wears out faster. The horizontal configuration makes this bundle a fit for attic-mounted or side-discharge applications, not standard upflow closet installs.
Matched bundle vs. buying components separately
Buying a condenser, coil, and furnace separately lets you mix brands and match configurations, but you carry the burden of confirming AHRI compatibility across components. This bundle ships as a pre-matched set — the GLXS4BA2410-GR9T800804BX-CHPTA3026B3 has been rated together, so you're not chasing AHRI numbers across three separate spec sheets. For most standard horizontal residential installs, the bundle approach saves time and eliminates a common source of installation error. If you have an unusual duct layout or need a higher AFUE furnace, buying separately may make more sense.
Where it fits best
- Attic-mounted horizontal systems in single-story homes
- Crawlspace installations where the air handler sits on its side
- Replacement systems in homes already plumbed for natural gas
- New construction builds in climates that need both dedicated gas heat and central cooling
- Mobile or manufactured homes with horizontal furnace configurations (verify manufacturer approval)
Why R-32 matters for this install
R-32 is replacing R-410A across much of the HVAC industry because it has roughly one-third the global warming potential. It also runs at slightly higher pressures, which means recovery equipment and technician certification matter — any EPA 608-certified tech can handle it, but it's worth confirming your gauges and recovery machine are rated for R-32 before the install day. On the supply side, R-32 equipment is increasingly available and priced competitively, so choosing it now doesn't mean paying a premium for forward-looking refrigerant compliance.
Installation & what else you’ll need
This system runs on single-phase, 208–230V, 60Hz power — standard residential service in most markets. The horizontal configuration means the furnace and coil mount in a non-standard orientation, so verify your existing duct connections and drain pan setup before ordering. You'll need a disconnect whip sized for the condenser, a concrete pad or pre-formed equipment pad for the outdoor unit, a compatible communicating or conventional thermostat, and proper refrigerant line sets sized for R-32. Refrigerant handling requires EPA 608 certification. Gas connections to the furnace require a licensed gas fitter or HVAC contractor in most jurisdictions. Not available for sale or shipment to California.
Frequently Asked Questions
How many tons is the Goodman GLXS4BA2410-GR9T800804BX-CHPTA3026B3?
The GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is a 2-ton system, rated at 24,000 BTU of cooling capacity. That makes it appropriate for smaller to mid-size homes, typically in the 900–1,300 square foot range depending on insulation, climate, and load — confirm with a Manual J before ordering.
What SEER2 rating does this Goodman gas-electric split system have?
This Goodman bundle is rated at 15.2 SEER2 and 12 EER2. These are the current federal efficiency metrics replacing legacy SEER ratings. The system is AHRI certified as a matched set, so those numbers reflect actual combined performance of the condenser, coil, and furnace together.
What refrigerant does the GLXS4BA2410 condenser use?
The GLXS4BA2410 condenser uses R-32 refrigerant. R-32 has a lower global warming potential than R-410A. Handling requires EPA 608 certification, and you should confirm your recovery equipment is rated for R-32 before the install.
Is this Goodman split system available in California?
No. The GLXS4BA2410-GR9T800804BX-CHPTA3026B3 is available nationwide except California. California has its own refrigerant and efficiency regulations that this system does not currently meet for sale or installation in that state.
What does horizontal configuration mean for a gas furnace split system?
Horizontal configuration means the furnace is designed to lie on its side with airflow moving sideways rather than straight up. This is required for attic or crawlspace installs where a standard upflow furnace won't fit. The coil and ductwork connections are oriented accordingly — it is not interchangeable with an upflow setup without modification.
Does this Goodman bundle include the coil and furnace, or just the condenser?
This bundle includes all three components: the GLXS4BA2410 condenser, the GR9T800804BX gas furnace, and the CHPTA3026B3 horizontal coil. They ship as a pre-matched, AHRI-certified set. You still need line sets, a thermostat, electrical whip, and gas connection completed by a licensed installer.
White Paper
- Goodman GLXS4B Spec Sheet
- Goodman GLXS Split AC Installation Manual
- Goodman GR9T80/GD9T80 Spec Sheet
- Goodman GR9T80/GD9T80 Installation Manual
- Goodman Evaporator Coil Spec Sheet
- Goodman CHPTA Coil Installation Manual
- Goodman GLXS4BA Repair Parts List (RP-G4341A)
- Goodman GR9T Repair Parts List (RP-G2355)
- Goodman CHPTA Repair Parts List (RP-4362)