Goodman 3.5 Ton 16.5 SEER2 8.6 HSPF2 96% AFUE 80,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 | GZV7SA4210 GRVS960805CU CHPEA6030C3

Goodman

Local HVAC Offers

Special pricing available — add to cart or call for details.
Limited-time availability.
About this promotion
Cyber Weekend Sales Event

No reviews yet Write a Review
SKU:
GZV7SA4210-GRVS960805CU-CHPEA6030C3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
37.00 (in)
Height:
39.00 (in)
Depth:
12.63 (in)

Questions about Goodman 3.5 Ton 16.5 SEER2 8.6 HSPF2 96% AFUE 80,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 | GZV7SA4210 GRVS960805CU CHPEA6030C3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

At a glance

Fast Shipping

Customer Support

Warranty Coverage

Financing Avaliable

$9,163.00

45 in stock • Ships in 2-3 Business Days

Description

The Goodman 3.5 Ton 16.5 SEER2 8.6 HSPF2 96% AFUE 80,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 (GZV7SA4210 / GRVS960805CU / CHPEA6030C3) is a complete dual fuel heating and cooling system that pairs an electric heat pump with a gas furnace. This AHRI-matched system combines a 3.5-ton R-32 heat pump, 96% AFUE single-stage gas furnace, and cased evaporator coil so the heat pump handles cooling and mild-weather heating, while the furnace takes over when outdoor temperatures drop.

Designed for upflow installation, the system uses the furnace's variable-speed ECM blower motor to move air for both the heat pump and the gas burners. With a dual-fuel thermostat or outdoor temperature control, the system switches to gas heat below a set balance point, which keeps homes comfortable in cold snaps and lets you choose the more economical fuel for your local utility rates.

Key Features

  • 3.5 Ton Cooling Capacity – AHRI-rated 40,500 BTU/h of cooling

  • 16.5 SEER2 / 10 EER2 – Certified matched-system cooling efficiency

  • 8.6 HSPF2 Heat Pump Heating – 41,000 BTU/h at 47°F and 28,000 BTU/h at 17°F

  • 80,000 BTU Gas Furnace – Single-stage heating with 96% AFUE efficiency

  • Dual Fuel Operation – Heat pump for efficient mild-weather heat, gas furnace for cold-weather backup

  • Ultra Low NOx Furnace – 14 ng/J NOx emissions for strict air-quality districts

  • Upflow R-32 System – Uses lower-GWP R-32 refrigerant

System Components Included

  • Goodman GZV7SA4210 3.5 Ton R-32 Heat Pump

  • Goodman GRVS960805CU 80,000 BTU 96% AFUE Single-Stage Gas Furnace (Ultra Low NOx)

  • Goodman CHPEA6030C3 Cased Horizontal R-32 Evaporator Coil

Compatibility & Installation Notes

The GZV7SA4210 / GRVS960805CU / CHPEA6030C3 system is AHRI certified under reference number 215434339 and is designed for residential upflow applications. Compatibility with the property's ductwork, electrical service, gas supply, refrigerant lines, condensate drainage, and furnace venting must be confirmed before installation. The communicating GZV7SA4210 heat pump and GRVS960805CU furnace connect over the two communication wires, and the furnace control manages dual fuel switchover on its own, so a standard single-stage 24 VAC thermostat is all you need. No separate dual fuel kit is required.

Specifications

  • System Type: Hybrid Dual Fuel Heat Pump & Gas Furnace Split System

  • AHRI Reference Number: 215434339

  • Cooling Capacity: 40,500 BTU/h

  • Heat Pump Heating Capacity: 41,000 BTU/h at 47°F / 28,000 BTU/h at 17°F

  • Cooling Efficiency: 16.5 SEER2 / 10 EER2

  • Heating Efficiency: 8.6 HSPF2

  • Furnace Input / Output: 80,000 / 76,880 BTU/h

  • Furnace Efficiency: 96% AFUE

  • Refrigerant / Orientation: R-32 / Upflow

Installation Notes

  • Verify compatibility with the existing upflow ductwork

  • Confirm electrical service and natural gas connection requirements

  • Check the required refrigerant line sizes before installation

  • Ensure PVC (Category IV) venting for the high-efficiency condensing furnace

  • Connect the 1 and 2 communication wires between the furnace and heat pump and set up the thermostat for single-stage AC and single-stage gas heat

  • Confirm local air district NOx requirements before installation

  • Installation should be completed by a qualified HVAC professional

Frequently Asked Questions

What is included in this Goodman HVAC system?

The package includes the GZV7SA4210 heat pump, GRVS960805CU gas furnace, and CHPEA6030C3 cased evaporator coil.

How does a dual fuel system work?

The heat pump cools in summer and heats in mild weather. When the outdoor temperature falls below the balance point set on the thermostat, the gas furnace takes over heating, so the system always runs on the more effective heat source.

What is the heating rating of the heat pump?

This matched system is rated at 8.6 HSPF2, with 41,000 BTU/h of heat pump heating at 47°F.

What is the cooling capacity of this system?

The system provides 3.5 tons with an AHRI-rated 40,500 BTU/h of cooling.

Is the furnace single-stage or two-stage?

The Goodman GRVS960805CU is a single-stage gas furnace.

What does 96% AFUE mean?

It means approximately 96% of the furnace's fuel is converted into usable heating energy.

Does this system use R-32 refrigerant?

Yes. The heat pump and evaporator coil are designed for R-32 refrigerant.

White Paper

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
37.00 (in)
Height:
39.00 (in)
Depth:
12.63 (in)
Weight:
421.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
AHRI Certified:
Yes
Capacity (Tons):
3.5
Product Category:
Hybrid Dual Fuel Split System
Configuration:
Upflow
Cabinet Width (in):
21
AHRI Reference Number:
215434339
Color:
Gray
AFUE:
96%
Blower Motor Type:
ECM Variable Speed
Heating Stages:
Single Stage
EER2:
10 EER2
Electrical Frequency:
60 Hz
Electrical Phase:
1-Phase
Liquid Line Size:
3/8 in
Suction Line Size:
1-1/8 in
Line Set Connection Type:
Braze
Input (BTU):
80,000
Prop 65 Warning:
Yes
SEER2:
16 SEER2
HSPF2:
8 HSPF2
Refrigerant Type:
R-32
Vent Type:
PVC / Category IV
Low NOx:
Ultra Low NOx
Cooling Capacity (BTU):
42,000
Heating Capacity (BTU):
42,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Variable Speed
Voltage / Phase:
208/230V 1-Phase
Shipping Weight:
421 lb
Heat Pump GZV7SA4210 - Nominal Capacity (Tons):
3.5
Heat Pump GZV7SA4210 - Cooling Capacity (BTU/h):
42,000
Heat Pump GZV7SA4210 - Refrigerant:
R-32
Heat Pump GZV7SA4210 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump GZV7SA4210 - Minimum Circuit Ampacity (MCA):
37.5 A
Heat Pump GZV7SA4210 - Maximum Overcurrent Protection (MOP):
40 A
Heat Pump GZV7SA4210 - Compressor Type:
Inverter
Heat Pump GZV7SA4210 - Compressor Stages:
Variable Speed
Heat Pump GZV7SA4210 - Liquid Line Size:
3/8 in
Heat Pump GZV7SA4210 - Suction Line Size:
1-1/8 in
Heat Pump GZV7SA4210 - Shipping Weight:
198 lb
Heat Pump GZV7SA4210 - UPC:
663051747210
Furnace GRVS960805CU - Input (BTU/h):
80,000
Furnace GRVS960805CU - Output (BTU/h):
76,880
Furnace GRVS960805CU - AFUE:
96%
Furnace GRVS960805CU - Heating Stages:
Single Stage
Furnace GRVS960805CU - Blower Motor Type:
ECM Variable Speed
Furnace GRVS960805CU - Maximum Cooling Capacity (Tons):
5
Furnace GRVS960805CU - Configuration:
Upflow/Horizontal
Furnace GRVS960805CU - Cabinet Width:
21 in
Furnace GRVS960805CU - Vent Type:
PVC / Category IV
Furnace GRVS960805CU - Gas Type:
Natural Gas
Furnace GRVS960805CU - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GRVS960805CU - Unit Dimensions (W x D x H):
21 in x 28.875 in x 34.5 in
Furnace GRVS960805CU - Shipping Weight:
147 lb
Furnace GRVS960805CU - NOx Emissions:
Ultra Low NOx (14 ng/J)
Evaporator Coil CHPEA6030C3 - Nominal Capacity (Tons):
5
Evaporator Coil CHPEA6030C3 - Cased/Uncased:
Cased
Evaporator Coil CHPEA6030C3 - Configuration:
Horizontal
Evaporator Coil CHPEA6030C3 - Cabinet Width:
21 in
Evaporator Coil CHPEA6030C3 - Metering Device:
TXV
Evaporator Coil CHPEA6030C3 - Refrigerant:
R-32
Evaporator Coil CHPEA6030C3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPEA6030C3 - Suction Line Size:
7/8 in
Dual Fuel Control:
Built-In (Communicating Furnace Control)

Warranty Information

10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase

Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document


Fast Shipping

Easy Returns

Warranty Coverage

Financing Available