null

Goodman 3.5 Ton 17 SEER2 8.6 HSPF2 97% AFUE 120,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 | GZV7SA4210 GRVM971205DN CHPEA4830D3

Goodman

Local HVAC Offers

Special pricing available — add to cart or call for details.
Limited-time availability.
About this promotion
Cyber Weekend Sales Event

No reviews yet Write a Review
SKU:
GZV7SA4210-GRVM971205DN-CHPEA4830D3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
37.00 (in)
Height:
39.00 (in)
Depth:
12.63 (in)

Questions about Goodman 3.5 Ton 17 SEER2 8.6 HSPF2 97% AFUE 120,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 | GZV7SA4210 GRVM971205DN CHPEA4830D3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

At a glance

Fast Shipping

Customer Support

Warranty Coverage

Financing Avaliable

$9,298.00

45 in stock • Ships in 2-3 Business Days

Description

The Goodman 3.5 Ton 17 SEER2 8.6 HSPF2 97% AFUE 120,000 BTU Hybrid Dual Fuel Heat Pump & Gas Furnace Split System Upflow R-32 (GZV7SA4210 / GRVM971205DN / CHPEA4830D3) is a complete dual fuel heating and cooling system that pairs an electric heat pump with a gas furnace. This AHRI-matched system combines a 3.5-ton R-32 heat pump, 97% AFUE modulating gas furnace, and cased evaporator coil so the heat pump handles cooling and mild-weather heating, while the furnace takes over when outdoor temperatures drop.

Designed for upflow installation, the system uses the furnace's variable-speed ECM blower motor to move air for both the heat pump and the gas burners. With a dual-fuel thermostat or outdoor temperature control, the system switches to gas heat below a set balance point, which keeps homes comfortable in cold snaps and lets you choose the more economical fuel for your local utility rates.

Key Features

  • 3.5 Ton Cooling Capacity – AHRI-rated 40,500 BTU/h of cooling

  • 17 SEER2 / 10 EER2 – Certified matched-system cooling efficiency

  • 8.6 HSPF2 Heat Pump Heating – 41,000 BTU/h at 47°F and 28,000 BTU/h at 17°F

  • 120,000 BTU Gas Furnace – Modulating heating with 97% AFUE efficiency

  • Dual Fuel Operation – Heat pump for efficient mild-weather heat, gas furnace for cold-weather backup

  • Upflow R-32 System – Uses lower-GWP R-32 refrigerant

System Components Included

  • Goodman GZV7SA4210 3.5 Ton R-32 Heat Pump

  • Goodman GRVM971205DN 120,000 BTU 97% AFUE Modulating Gas Furnace

  • Goodman CHPEA4830D3 Cased Horizontal R-32 Evaporator Coil

Compatibility & Installation Notes

The GZV7SA4210 / GRVM971205DN / CHPEA4830D3 system is AHRI certified under reference number 215434324 and is designed for residential upflow applications. Compatibility with the property's ductwork, electrical service, gas supply, refrigerant lines, condensate drainage, and furnace venting must be confirmed before installation. The communicating GZV7SA4210 heat pump and GRVM971205DN furnace connect over the two communication wires, and the furnace control manages dual fuel switchover on its own, so a standard single-stage 24 VAC thermostat is all you need. No separate dual fuel kit is required.

Specifications

  • System Type: Hybrid Dual Fuel Heat Pump & Gas Furnace Split System

  • AHRI Reference Number: 215434324

  • Cooling Capacity: 40,500 BTU/h

  • Heat Pump Heating Capacity: 41,000 BTU/h at 47°F / 28,000 BTU/h at 17°F

  • Cooling Efficiency: 17 SEER2 / 10 EER2

  • Heating Efficiency: 8.6 HSPF2

  • Furnace Input / Output: 120,000 / 116,400 BTU/h

  • Furnace Efficiency: 97% AFUE

  • Refrigerant / Orientation: R-32 / Upflow

Installation Notes

  • Verify compatibility with the existing upflow ductwork

  • Confirm electrical service and natural gas connection requirements

  • Check the required refrigerant line sizes before installation

  • Ensure PVC (Category IV) venting for the high-efficiency condensing furnace

  • Connect the 1 and 2 communication wires between the furnace and heat pump and set up the thermostat for single-stage AC and single-stage gas heat

  • Installation should be completed by a qualified HVAC professional

Frequently Asked Questions

What is included in this Goodman HVAC system?

The package includes the GZV7SA4210 heat pump, GRVM971205DN gas furnace, and CHPEA4830D3 cased evaporator coil.

How does a dual fuel system work?

The heat pump cools in summer and heats in mild weather. When the outdoor temperature falls below the balance point set on the thermostat, the gas furnace takes over heating, so the system always runs on the more effective heat source.

What is the heating rating of the heat pump?

This matched system is rated at 8.6 HSPF2, with 41,000 BTU/h of heat pump heating at 47°F.

What is the cooling capacity of this system?

The system provides 3.5 tons with an AHRI-rated 40,500 BTU/h of cooling.

Is the furnace single-stage or two-stage?

The Goodman GRVM971205DN is a modulating gas furnace.

What does 97% AFUE mean?

It means approximately 97% of the furnace's fuel is converted into usable heating energy.

Does this system use R-32 refrigerant?

Yes. The heat pump and evaporator coil are designed for R-32 refrigerant.

White Paper

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
37.00 (in)
Height:
39.00 (in)
Depth:
12.63 (in)
Weight:
433.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
AHRI Certified:
Yes
Capacity (Tons):
3.5
Product Category:
Hybrid Dual Fuel Split System
Configuration:
Upflow
Cabinet Width (in):
24.5
AHRI Reference Number:
215434324
Color:
Gray
AFUE:
97%
Blower Motor Type:
ECM Variable Speed
Airflow (CFM):
2,000
Heating Stages:
Modulating
EER2:
10 EER2
Electrical Frequency:
60 Hz
Electrical Phase:
1-Phase
Liquid Line Size:
3/8 in
Suction Line Size:
1-1/8 in
Line Set Connection Type:
Braze
Input (BTU):
120,000
Prop 65 Warning:
Yes
SEER2:
17 SEER2
HSPF2:
8 HSPF2
Refrigerant Type:
R-32
Vent Type:
PVC / Category IV
Low NOx:
Standard
Cooling Capacity (BTU):
42,000
Heating Capacity (BTU):
42,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Variable Speed
Voltage / Phase:
208/230V 1-Phase
Shipping Weight:
433 lb
Heat Pump GZV7SA4210 - Nominal Capacity (Tons):
3.5
Heat Pump GZV7SA4210 - Cooling Capacity (BTU/h):
42,000
Heat Pump GZV7SA4210 - Refrigerant:
R-32
Heat Pump GZV7SA4210 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump GZV7SA4210 - Minimum Circuit Ampacity (MCA):
37.5 A
Heat Pump GZV7SA4210 - Maximum Overcurrent Protection (MOP):
40 A
Heat Pump GZV7SA4210 - Compressor Type:
Inverter
Heat Pump GZV7SA4210 - Compressor Stages:
Variable Speed
Heat Pump GZV7SA4210 - Liquid Line Size:
3/8 in
Heat Pump GZV7SA4210 - Suction Line Size:
1-1/8 in
Heat Pump GZV7SA4210 - Shipping Weight:
198 lb
Heat Pump GZV7SA4210 - UPC:
663051747210
Furnace GRVM971205DN - Input (BTU/h):
120,000
Furnace GRVM971205DN - Output (BTU/h):
116,400
Furnace GRVM971205DN - AFUE:
97%
Furnace GRVM971205DN - Heating Stages:
Modulating
Furnace GRVM971205DN - Blower Motor Type:
ECM Variable Speed
Furnace GRVM971205DN - Maximum Cooling Capacity (Tons):
5
Furnace GRVM971205DN - Configuration:
Upflow/Horizontal
Furnace GRVM971205DN - Cabinet Width:
24.5 in
Furnace GRVM971205DN - Vent Type:
PVC / Category IV
Furnace GRVM971205DN - Gas Type:
Propane Convertible
Furnace GRVM971205DN - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GRVM971205DN - Unit Dimensions (W x D x H):
24.5 in x 28.875 in x 34.5 in
Furnace GRVM971205DN - Shipping Weight:
157 lb
Evaporator Coil CHPEA4830D3 - Nominal Capacity (Tons):
4
Evaporator Coil CHPEA4830D3 - Cased/Uncased:
Cased
Evaporator Coil CHPEA4830D3 - Configuration:
Horizontal
Evaporator Coil CHPEA4830D3 - Cabinet Width:
24.5 in
Evaporator Coil CHPEA4830D3 - Metering Device:
TXV
Evaporator Coil CHPEA4830D3 - Refrigerant:
R-32
Evaporator Coil CHPEA4830D3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPEA4830D3 - Suction Line Size:
7/8 in
Dual Fuel Control:
Built-In (Communicating Furnace Control)

Warranty Information

10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase

Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document


Fast Shipping

Easy Returns

Warranty Coverage

Financing Available