Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GD9T800805CX CHPTA3630C3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA3610-GD9T800805CX-CHPTA3630C3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)

Questions about Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GD9T800805CX CHPTA3630C3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$5,011.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GD9T800805CX CHPTA3630C3

Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32, model GLXS4BA3610 GD9T800805CX CHPTA3630C3 - view 5
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610 R-32 outdoor air conditioner with one GD9T800805CX GD9T80 gas furnace and one CHPTA3630C3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system built around a single-stage outdoor section and a forced-air indoor air handler section. The outdoor unit uses R-32 refrigerant and is factory charged for 15 feet of interconnecting tubing to simplify commissioning. The indoor furnace provides two-stage natural gas heat with a 80% AFUE rating and uses a 9-speed ECM blower for ducted air delivery. The indoor coil is a cased horizontal a-coil (evaporator coil) designed for horizontal installation, and it includes a factory-installed TXV for controlled refrigerant metering. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V controls and 208/230V single-phase outdoor power.

Performance

Cooling performance is driven by a single-stage scroll compressor and a PSC condenser fan motor that support stable airflow through the outdoor coil. The GLXS4B series is rated up to 15.2 SEER2, with realized efficiency determined by the matched coil, blower setup, and installation conditions. Refrigerant connections use 0.38" liquid and 0.88" suction service valves to align with common 3 ton line-set sizing. Indoors, the furnace blower provides the system’s air delivery and can be configured for the required CFM to match coil capacity and duct static pressure. The TXV-equipped coil supports consistent superheat control across operating conditions, improving stability during cycling and varying load. Across the package, the outdoor condenser rejects heat to ambient while the indoor coil absorbs sensible and latent heat from return air for a conventional split-system refrigeration circuit.

Smart Features

Controls are based on standard 24V thermostat signaling so the system can be applied with widely used non-communicating thermostats. The furnace control board supports self-diagnostics and integrates heating safety logic with blower timing for staged heat operation. Blower speed configuration is set at the furnace, allowing installers to select airflow targets for cooling, heating, and continuous circulation modes. If zoning dampers are used in the duct system, the ECM blower provides a range of airflow options that can be matched to zoning design and static pressure limits. The outdoor section uses conventional contactor-based control and includes protection devices that interrupt operation under abnormal pressure conditions. This architecture keeps service access straightforward by separating refrigerant service at the condenser from combustion and airflow service at the furnace and coil.

Comfort & Noise

Acoustic performance is supported by the outdoor unit’s published 67 dBA rating for the 3 ton chassis, helping manage exterior noise in residential and multi-family placements. Two-stage gas heat reduces temperature swing by operating at a lower firing rate when load is moderate, then stepping to high fire when demand increases. The ECM blower enables lower continuous fan speed options for air mixing while maintaining controlled ramping for heating and cooling calls. Air delivery quality is governed by duct design and airflow setup, with the coil selected to align cabinet size and refrigerant connections to the furnace platform. The TXV coil stabilizes evaporator operation as indoor load changes, supporting humidity removal in cooling mode when airflow and charge are properly set. Overall comfort is produced by coordinated capacity at the outdoor condenser, metering at the coil, and airflow control at the furnace.

Use Case Fit

This package is suited for ducted residential applications and can also support light commercial or multi-family use where a single outdoor condenser serves one air distribution system. The horizontal coil orientation supports common install scenarios such as vertical closets and basements for CAPTA coils or attic and crawlspace horizontal runs for CHPTA coils. The furnace is designed for downflow or horizontal left/right installation, supporting layout flexibility when supply and return are constrained by structure. R-32 refrigerant is used for the refrigeration circuit, and installers should follow applicable A2L handling practices and local code requirements. In coastal or high-wind regions, the outdoor cabinet can be properly anchored to meet 2023 Florida Building Code unit integrity requirements when installed with the appropriate anchoring method. This configuration fits mixed-humid and hot-humid climates where staged gas heat and controlled evaporator metering help manage seasonal load changes.

Value & Reliability

Reliability is supported by outdoor components including a factory-installed filter drier, an enclosed contactor, and a high-pressure switch that protect the refrigeration circuit. The outdoor cabinet uses steel louvers and a coil guard to reduce incidental damage while maintaining airflow across the condenser coil. The coil cabinet includes insulated casing and a thermoplastic drain pan with secondary drain connections to support condensate management. The furnace cabinet is a heavy-gauge steel enclosure with low cabinet air leakage targets and serviceable access for blower and controls. Across the system, common service valve sizes and standard electrical requirements support parts availability and routine maintenance workflows. AHRI certification and ETL listing provide standardized performance and safety references for the matched equipment family.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with a 80% AFUE two-stage gas furnace and a TXV-metered indoor coil to cover both cooling and heating seasons. The outdoor unit provides the refrigeration work while the furnace supplies airflow, filtration interface, and staged combustion heat. The selected coil completes the refrigerant circuit indoors and is matched by cabinet size and orientation to support practical installation. For contractors, the system architecture keeps commissioning tasks clear: set airflow, confirm charge, and verify staged heat operation. For wholesale and D2C buyers, the value is a known Goodman equipment family with defined capacities, standard controls, and service-accessible construction. Choose this configuration when you need a conventional ducted AC plus gas furnace system with clear component roles and field-configurable airflow.

Key Features

  • R-32 split-system architecture: Single outdoor condenser and matched indoor coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage scroll compression: Outdoor compressor operates in single stage to deliver nominal 3 ton capacity with thermostat-based cycling control.
  • Two-stage gas heat section: GD9T800805CX furnace provides low and high fire operation (56,000 to 80,000 BTU/h input) to track load.
  • ECM indoor airflow management: 9-speed ECM blower supports configurable airflow targets for cooling, heating, and continuous circulation.
  • TXV-metered evaporator coil: CHPTA3630C3 coil includes a factory TXV for controlled refrigerant metering and stable evaporator superheat.
  • Multi-position indoor installation: Furnace supports downflow or horizontal left/right, and the coil supports horizontal mounting for common duct layouts.
  • Service and protection devices: Filter drier, sweat service valves, enclosed contactor, and high-pressure switch support commissioning and system protection.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)
Weight:
459.00 LBS
Product Category:
Gas Heating & Air Conditioner Bundle
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
AHRI Certified:
Yes
EER:
12
Capacity (Tons):
3
Configuration:
Horizontal
AHRI Reference Number:
214859853
Cabinet Width (in):
21
AFUE:
80%
Airflow (CFM):
2,000
Blower Motor Type:
ECM Constant Torque
EER2:
12 EER2
Electrical Frequency:
60 Hz
Color:
Gray
Line Set Connection Type:
Braze
Heating Input (BTU):
70,000 - 99,000 BTU
Heating Stages:
Two Stage
Electrical Phase:
1-Phase
Liquid Line Size:
3/8 in
Prop 65 Warning:
Yes
SEER2:
14 SEER2
Shipping Weight:
372 lb
Vent Type:
Chimney / Category I
Refrigerant Type:
R-32
Unit Weight:
342 lb
Cooling Capacity (BTU):
36,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA3610 - Nominal Capacity (Tons):
3
Condenser GLXS4BA3610 - Cooling Capacity (BTU/h):
36,000
Condenser GLXS4BA3610 - Refrigerant:
R-32
Condenser GLXS4BA3610 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA3610 - Minimum Circuit Ampacity (MCA):
17.8 A
Condenser GLXS4BA3610 - Maximum Overcurrent Protection (MOP):
30 A
Condenser GLXS4BA3610 - Compressor Type:
Scroll
Condenser GLXS4BA3610 - Compressor Stages:
Single Stage
Condenser GLXS4BA3610 - Liquid Line Size:
3/8 in
Condenser GLXS4BA3610 - Suction Line Size:
7/8 in
Condenser GLXS4BA3610 - Sound Level (dB):
67
Condenser GLXS4BA3610 - Unit Dimensions (W x D x H):
29 in x 29 in x 39.5 in
Condenser GLXS4BA3610 - Unit Weight:
158 lb
Condenser GLXS4BA3610 - Shipping Weight:
173 lb
Furnace GD9T800805CX - Input (BTU/h):
80,000
Furnace GD9T800805CX - Output (BTU/h):
64,000
Furnace GD9T800805CX - AFUE:
80%
Furnace GD9T800805CX - Heating Stages:
Two Stage
Furnace GD9T800805CX - Blower Motor Type:
ECM Constant Torque
Furnace GD9T800805CX - Maximum Cooling Capacity (Tons):
5
Furnace GD9T800805CX - Configuration:
Downflow/Horizontal
Furnace GD9T800805CX - Cabinet Width:
21 in
Furnace GD9T800805CX - Vent Type:
Chimney / Category I
Furnace GD9T800805CX - Gas Type:
Propane Convertible
Furnace GD9T800805CX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GD9T800805CX - Unit Dimensions (W x D x H):
21 in x 28 in x 19.5 in
Furnace GD9T800805CX - Shipping Weight:
129 lb
Evaporator Coil CHPTA3630C3 - Nominal Capacity (Tons):
3
Evaporator Coil CHPTA3630C3 - Cased/Uncased:
Cased
Evaporator Coil CHPTA3630C3 - Configuration:
Horizontal
Evaporator Coil CHPTA3630C3 - Cabinet Width:
30 in
Evaporator Coil CHPTA3630C3 - Metering Device:
TXV
Evaporator Coil CHPTA3630C3 - Refrigerant:
R-32
Evaporator Coil CHPTA3630C3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPTA3630C3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What size is the ?
The is a 3 ton unit.
Is the AHRI certified?
Yes. The AHRI reference number is 214859853.
What is the AFUE of the ?
The is rated at 80% AFUE.
What is the heating input of the ?
The heating input is 70,000 - 99,000 BTU BTU.
What is the SEER2 rating of the ?
The is rated at 14 SEER2 SEER2.
What refrigerant does the use?
It uses R-32 refrigerant.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA3610-GD9T800805CX-CHPTA3630C3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA3610-GD9T800805CX-CHPTA3630C3?
The GLXS4BA3610-GD9T800805CX-CHPTA3630C3 is made by Goodman.