null

Goodman 3 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9T800803BN CHPTA3630B3

Goodman

Local HVAC Offers

Special pricing available — add to cart or call for details.
Limited-time availability.
About this promotion
Cyber Weekend Sales Event

No reviews yet Write a Review
SKU:
GLXS4BA3610-GR9T800803BN-CHPTA3630B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)

Questions about Goodman 3 Ton 15.2 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9T800803BN CHPTA3630B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

At a glance

Fast Shipping

Customer Support

Warranty Coverage

Financing Avaliable

$4,599.00

45 in stock • Ships in 3-4 Business Days

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610 R-32 outdoor air conditioner with one GR9T800803BN gas furnace and one CHPTA3630B3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system paired with ducted gas heat for a single air distribution path. The outdoor condenser uses R-32 refrigerant and is designed for conventional split-system line-set connections to the matched indoor coil. The furnace provides two-stage combustion heat while the ECM blower establishes airflow across the evaporator coil and through the duct system. The coil is a cased horizontal a-coil (evaporator coil) built for horizontal installation and includes a factory TXV for controlled refrigerant metering. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control with non-communicating equipment logic.

Performance

Cooling performance is driven by a single-stage scroll and condenser fan that cycle to match thermostat demand. The GLXS4B series is rated up to 15.2 SEER2, with realized efficiency dependent on the matched coil, blower configuration, and installation conditions. Refrigerant connections use 0.375" liquid and 0.875" suction service valves consistent with typical 3 ton line-set sizing. In heating mode, the furnace operates in low and high fire stages from 56,000 to 80,000 BTU/h input to better track load and manage temperature rise. Indoors, airflow is configured at the furnace to support the coil’s heat transfer and the duct system’s static pressure constraints. The TXV coil stabilizes refrigerant metering under changing indoor load to support consistent evaporator superheat and latent capacity.

Smart Features

Controls follow standard 24V heat/cool call logic, supporting widely used non-communicating thermostats and third-party smart thermostats that provide conventional outputs. The furnace control system coordinates ignition sequencing, safety proving, and blower timing, and it supports onboard diagnostics for service troubleshooting. Blower speed selection is configured at the furnace to set airflow targets for cooling, heating, and continuous circulation. GR9T furnaces include provisions associated with A2L system monitoring used with R-32 equipment, supporting integration of sensor and alarm logic when applied in the system design. When applied with zoning dampers, airflow setup and duct design determine how well the system maintains coil temperature, airflow balance, and noise control across zones. This split architecture keeps service roles clear by separating refrigerant service at the condenser from combustion, airflow, and condensate service at the indoor section.

Comfort & Noise

Outdoor acoustic performance is supported by a published 67 dBA rating for the 3 ton chassis to help manage exterior noise at the placement location. Two-stage furnace operation reduces on/off cycling by using low fire for moderate demand, then stepping to high fire when load increases. The ECM blower supports smoother airflow transitions and can be configured for lower continuous circulation speeds for improved mixing and filtration through the return path. Cooling comfort is governed by coil sizing and airflow balance, with cabinet width matching used to control face velocity across the indoor heat exchanger. Humidity performance depends on achieving the intended evaporator temperature through correct airflow and refrigerant charge, with the TXV helping maintain stable metering. Overall comfort is produced by coordinated heat rejection at the outdoor coil, heat absorption at the indoor coil, and ducted air delivery through the furnace blower.

Use Case Fit

This package is suited for ducted residential applications and can support light commercial or multi-family use where one outdoor condenser serves one duct system. The furnace supports upflow or horizontal left/right installation, while the coil supports horizontal mounting to match common vertical or horizontal duct layouts. R-32 refrigerant is used for the refrigeration circuit, and installation should follow applicable A2L handling practices and local code requirements. For GR9T96 configurations, the furnace uses PVC venting and can be configured as 1-pipe (exhaust only) or 2-pipe (dedicated combustion air) depending on installation design and code requirements. For GR9T80 configurations, venting is Category I non-condensing and combustion air requirements are governed by the installation environment and applicable codes. The furnace NOx classification for this model is > 40 NG/J NOx, which may support compliance requirements in regulated air districts depending on jurisdiction.

Value & Reliability

Reliability is supported by outdoor components including a factory-installed filter drier, accessible service valves, and refrigeration safety devices used for protection and diagnostics. The outdoor cabinet and louvered construction are designed to maintain condenser airflow while protecting the coil face from incidental impact. The furnace integrates safety controls for flame sensing, pressure proving, and limit protection to manage combustion operation over repeated cycles. Coil cabinet insulation and drain pan features support condensate management when installed with proper trapping and drainage. Airflow tuning is supported by the ECM blower and a cabinet width matched to the selected evaporator coil for stable air distribution. Across the package, standard electrical requirements and conventional 24V controls support straightforward replacement and service workflows.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with a 80% AFUE GR9T800803BN two-stage gas furnace and a TXV-metered CHPTA3630B3 evaporator coil to provide cooling and gas heat in one matched architecture. The outdoor condenser performs the refrigeration work, while the indoor coil provides the evaporator heat transfer surface and the furnace supplies airflow and combustion heat. Cabinet widths are selected so the furnace and coil align for practical installation and stable air distribution across the coil face. For contractors, commissioning focuses on blower airflow setup, refrigerant charge verification, venting and condensate completion where applicable, and verification of ignition and safety operation. For wholesale and D2C buyers, the value is a defined Goodman equipment set that uses serviceable components and conventional split-system architecture. Select this configuration when you need ducted central cooling with staged gas heat and clear component roles across the refrigeration and combustion sections.

Key Features

  • R-32 split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage cooling operation: Outdoor section cycles to thermostat demand to deliver nominal 3 ton capacity with conventional non-communicating controls.
  • Two-stage gas heat section: GR9T800803BN furnace operates in low and high fire from 56,000 to 80,000 BTU/h input to track load.
  • ECM indoor airflow management: Multi-speed blower supports airflow tuning for cooling, heating, and continuous circulation, with up to 1,200 CFM capability depending on model.
  • TXV-metered evaporator coil: CHPTA3630B3 coil includes a factory-installed TXV for controlled refrigerant metering and stable evaporator operation.
  • Mounting and orientation flexibility: Furnace supports upflow or horizontal left/right installation, and the coil supports horizontal mounting to match duct routing.
  • Service and protection devices: Filter drier, accessible service valves, and refrigeration safeties support commissioning, diagnostics, and circuit protection.

Videos

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)
Weight:
342.00 LBS
Cooling BTU | British Thermal Unit:
36,000
Brand:
Goodman
Configuration:
Horizontal
Capacity (Tons):
3
Prod Weight (lbs):
327
AFUE%:
80
EER2 | Energy Efficiency Ratio 2:
12
SEER2 | Seasonal Energy Efficiency Ratio 2:
15.2
Safety Information:
PROP 65 WARNING: This product and other products on our site may contain a chemical known to the State of California to cause cancer or birth defects or other reproductive harm.
AHRI Certified:
Yes
Voltage:
208 to 230
Refrigerant Type:
R32
Air Flow (CFM):
1200
Product Category:
Gas Heating & Air Conditioner Bundle
Electrical Frequency:
60hz
Electrical Phase:
1ph
Available Regions:
Nationwide - Except CA
Prop 65 Warning:
Yes
Vent Type:
Chimney Vent
Ship Weight (lbs):
357
Blower Motor Type:
ECM Multi-Speed
Cabinet Width (Inches):
17.5
AHRI Reference Number:
214859754
Heating BTU:
80,000
Gas Furnace Stages:
Two Stage
Line Set Connection Type:
Solder
Liquid Line Size | OD - Outside Diameter:
3/8
Color:
Gray

Warranty Information

10 Year Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase

Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document


Fast Shipping

Easy Returns

Warranty Coverage

Financing Available