Description
This LG single-zone ducted heat pump system pairs outdoor model KUSXE361A with a Multi-Position AHU indoor unit (listed on submittal as KNSLE362A) to deliver ducted comfort in one zone. It’s designed for buyers who want the look and coverage of ductwork while still using a modern outdoor unit architecture that can modulate output as conditions change. That makes it a strong candidate for larger single zones where comfort swings would otherwise be noticeable, especially during shoulder seasons and part-load operation. It also fits well in light commercial spaces that want a ducted solution without overcomplicating zoning.
Performance snapshot (from provided submittal): cooling capacity (min/rated/max) 14,400 / 32,600 / 34,000 BTU/h, and heating capacity (min/rated/max) 16,000 / 34,000 / 35,000 BTU/h. Efficiency is listed at 16.0 SEER2, 9.80 EER2, and 8.5 HSPF2. Outdoor operating range is listed as 14°F–118°F (cooling) and 4°F–64°F (heating). Refrigerant type is R32, with EEV refrigerant control noted in the system data.
Noise and airflow matter in ducted applications, and the submittal lists outdoor sound pressure at 52/54 dBA (cooling/heating) and indoor sound pressure at 40/37/35 dBA (high/medium/low). Indoor airflow is listed at 1,050/980/900 CFM (max high/medium/low), and maximum outdoor air volume is listed at 2,048 CFM. The AHU includes an access panel for a field-supplied 20 x 20 x 1 filter, helping standardize filter sourcing and routine service.
Electrical planning details (from submittal) list a power supply of 208-230 V, 60 Hz, 1 phase, with MOP 25 A and MCA 19.5 A. Acceptable operating voltage is listed as 187V–253V. Maximum vertical separation between outdoor and indoor is listed at 49.2 ft. As with the rest of this platform, the Multi-Position AHU requires an LG wall controller because it does not have an infrared receiver.
Key Features
-
Single-zone ducted heat pump pairing: ODU KUSXE361A paired to a Multi-Position AHU platform for ducted comfort delivery.
-
Verified capacity range: listed cooling 14,400 / 32,600 / 34,000 BTU/h and heating 16,000 / 34,000 / 35,000 BTU/h (min/rated/max).
-
Verified efficiency ratings: listed 16.0 SEER2, 9.80 EER2, and 8.5 HSPF2 for this pairing.
-
Verified operating range: listed 14°F–118°F cooling and 4°F–64°F heating outdoor range.
-
Verified sound pressure: listed ODU 52/54 dBA and IDU 40/37/35 dBA (cool/heat and high/med/low).
-
Airflow and filter access: listed IDU airflow up to 1,050 CFM and filter access panel for 20 x 20 x 1 field-supplied filter.
-
Wall controller required: Multi-Position AHU requires an LG wall controller (no infrared receiver).