Description
Product Summary
The RDI Systems PC349LZOP-3E is a 3-1/2 HP low temp scroll air-cooled condensing unit from the RDI 120 Series PC Pre-Charged line rated at 12,957 BTU/h (-20°F SST, 90°F ambient, R-404A). It is wired for 208/230V 3-phase 60 Hz power.
RDI PC systems ship pre-charged with refrigerant for up to 50 ft of line, which shortens field charging time on walk-in cooler and freezer installations. The air-cooled cabinet is rated for indoor or outdoor installation.
Approved refrigerants: R-404A. Pair it with a matching evaporator sized to the box load; contact HVAC365 for a system match.
Key Features
- 3-1/2 HP Scroll Compressor: sized for low temp walk-in duty (Copeland ZF11K4E)
- Published Capacity: 12,957 BTU/h at -20°F SST, 90°F ambient, R-404A for accurate load matching
- Refrigerant: approved for R-404A
- Pre-Charged System: factory charge for up to 50 ft of line reduces installation time
- Complete High Side: liquid line filter/drier, sight glass, pressure controls, receiver with valve and base valves
- Outdoor Ready: low-ambient controls, crankcase heater and weatherproof housing
- UL Listed: UL 1995 listed, leak and dielectric tested before shipment
Ideal Applications
- Walk-in freezers for restaurants and commercial kitchens
- Convenience store and grocery freezer boxes
- Ice cream and frozen food storage
- School, hospital and institutional freezers
- Replacement condensing units for existing walk-in freezer systems
Frequently Asked Questions
What refrigerant does the PC349LZOP-3E use?
The PC349LZOP-3E is approved for R-404A. RDI PC units ship pre-charged for up to 50 ft of line.
What power supply does the PC349LZOP-3E need?
It requires 208/230V 3-phase 60 Hz power, with a minimum circuit ampacity of 19 A and maximum overcurrent protection of 25 A.
How much refrigeration capacity does the PC349LZOP-3E provide?
It is rated at 12,957 BTU/h at -20°F SST, 90°F ambient, R-404A. Actual capacity depends on box temperature, ambient temperature and line length, so size the system to the calculated box load.
Is the PC349LZOP-3E for a walk-in cooler or freezer?
It is a low-temperature unit for walk-in freezers and other boxes held below freezing.
What evaporator should I pair with it?
Choose an evaporator rated for the same refrigerant and temperature application with capacity matched to the condensing unit at your design suction temperature. HVAC365 can help match the right evaporator to this unit.
White Paper