Larkin
Larkin 2.2 HP Walk-In Freezer Refrigeration System for 6' x 6' or 6' x 8' Box, R-454C (A2L), 208/230V 1-Phase | LCH0022LBACYA0200 LEL0065BY6EEAB0000
SKU: LCH0022LBACYA0200-LEL0065BY6EEAB0000
$10,622.83- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from MFG in 2-4 Weeks10 in stock -
Bohn
Bohn 2.2 HP Walk-In Freezer Refrigeration System for 6' x 6' or 6' x 8' Box, R-454C (A2L), 208/230V 1-Phase | BCH0022LBACYA0200 BEL0065BY6EEAB0000
SKU: BCH0022LBACYA0200-BEL0065BY6EEAB0000
$10,989.30- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 3-5 Business Days1 in stock
6' x 8' Walk-In Freezer Systems
A 6' x 8' walk-in freezer gives you about 48 square feet of floor space and, with a standard 8 ft ceiling, roughly 384 cubic feet of refrigerated volume. That size is a common fit for a restaurant that needs frozen storage beyond its reach-ins, an ice cream shop or a small bakery. Every system in this category pairs a condensing unit with the unit cooler its manufacturer selects for a box of this size, so the two halves of the system are balanced from day one instead of being matched by guesswork.
The systems here come from Bohn and Larkin. Each listing ships as a matched package and is selected to hold a freezer box at -10°F. Options include R-454C and R-448A refrigerant and both single-phase and three-phase 208/230V power, so you can match the system to the building and to the refrigerant your contractor prefers to work with.
How These 6' x 8' Systems Are Sized
Walk-in refrigeration is sized by heat load, not floor area alone. For a 6 ft x 8 ft freezer with an 8 ft ceiling held at -10°F, a typical heat load works out to about 5,692 BTU/h, and a heavy-use box can reach about 7,960 BTU/h. Typical use assumes normal door traffic and product that goes in already frozen. Heavy use covers frequent door openings, large deliveries of warm product and boxes that sit in a hot kitchen or an unconditioned space.
Manufacturers build in run-time margin, so a system rated somewhat above the calculated load is normal. A properly matched system runs roughly 18 hours a day, leaving time for defrost, which keeps temperatures steady without short cycling.
Buying Tips
- Confirm the real box size. Measure the inside dimensions and ceiling height. A taller ceiling or a box that is longer than listed adds load, so step up to the next size if you are between sizes.
- Think about how the box is used. If the door opens all day or you load hot product, size for the heavy-use number rather than the typical one.
- Check your power. Look at the electrical panel before ordering. Single-phase and three-phase versions are not interchangeable.
- Plan where the condensing unit goes. Outdoor and rooftop units need clearance for airflow. Indoor locations need ventilation so the unit is not breathing its own hot air.
- Pick the refrigerant on purpose. R-448A is widely used and familiar to most technicians. R-454A is a lower-GWP A2L refrigerant. Requirements vary by state and region, so confirm what applies to your project.
What It Takes to Install a Walk-In Freezer System
Installation should be done by a licensed refrigeration contractor with EPA Section 608 certification. The job includes mounting the unit cooler inside the box, setting the condensing unit, running and brazing the refrigerant lines, installing the drain line with a heated drain line and trap to keep it from freezing, wiring power and controls, evacuating the system and charging it. Line sets, drain line, electrical supplies and labor are not included with the equipment.
Things You Should Know Before You Buy
Local building, electrical and energy codes apply to walk-in installations and vary from place to place, so check with your contractor or local building department. The panels, door and floor of the box matter as much as the refrigeration system. Damaged door gaskets, a missing strip curtain or poorly sealed panel joints add heat load and can make even a correctly sized system struggle.
Frequently Asked Questions
Q: What size refrigeration system do I need for a 6' x 8' walk-in freezer?
A: With an 8 ft ceiling at -10°F, plan on about 5,692 BTU/h for typical use and about 7,960 BTU/h for heavy use. Every system in this category is matched for this box size, so choose based on your power supply and refrigerant preference.
Q: Is the unit cooler included?
A: Yes. Each system includes the condensing unit and the matched unit cooler. Line sets, drain line, electrical materials and installation are separate.
Q: My ceiling is taller than 8 ft. Will these systems still work?
A: A taller ceiling adds volume and load. If your ceiling is 9 or 10 ft, or the box sits in a hot area, consider the next larger size category.
Q: Can I use this system for a cooler instead?
A: No. Freezer systems use low-temperature equipment with defrost designed for frozen storage. Shop our walk-in cooler systems for a box held above freezing.
Q: How long does a walk-in freezer system last?
A: With regular maintenance, including clean condenser and evaporator coils, a clear drain and working door seals, commercial walk-in systems commonly last 10 to 15 years or more.