Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 115,000 BTU Heat, Low NOx, R-32, 208/230V 1-Phase | DHG0481DM00001S
SKU: DHG0481DM00001S
$10,271.89- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 115,000 BTU Heat, Low NOx, R-32, 208/230V 3-Phase | DHG0483DM00001S
SKU: DHG0483DM00001S
$10,373.69- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 140,000 BTU Heat, Low NOx, R-32, 208/230V 1-Phase | DHG0481DH00001S
SKU: DHG0481DH00001S
$10,381.89- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 70,000 BTU Heat, Low NOx, R-32, 460V 3-Phase | DHG0484DL00001S
SKU: DHG0484DL00001S
$10,472.93- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 140,000 BTU Heat, Low NOx, R-32, 208/230V 3-Phase | DHG0483DH00001S
SKU: DHG0483DH00001S
$10,485.84- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 115,000 BTU Heat, Low NOx, R-32, 460V 3-Phase | DHG0484DM00001S
SKU: DHG0484DM00001S
$10,580.84- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Packaged Rooftop Air Conditioner, R-32, 208/230V 3-Phase | DHC0483D000001S
SKU: DHC0483D000001S
$10,630.38- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 140,000 BTU Heat, Low NOx, R-32, 460V 3-Phase | DHG0484DH00001S
SKU: DHG0484DH00001S
$10,690.73- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 13.7 SEER2 Heat Pump Packaged Rooftop Unit, R-32, 575V 3-Phase | DSH0487D000001S
SKU: DSH0487D000001S
$10,825.82- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Packaged Rooftop Air Conditioner, R-32, 460V 3-Phase | DHC0484D000001S
SKU: DHC0484D000001S
$11,056.09- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 70,000 BTU Heat, Low NOx, R-32, 575V 3-Phase | DHG0487DL00001S
SKU: DHG0487DL00001S
$11,091.87- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 4 Ton 16.4 SEER2 Gas/Electric Packaged Rooftop Unit, 115,000 BTU Heat, Low NOx, R-32, 575V 3-Phase | DHG0487DM00001S
SKU: DHG0487DM00001S
$11,204.84- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock
4 Ton Rooftop Units
4-Ton Packaged Rooftop Units for Commercial Zones Between Small and Mid-Size
Four tons is nominally 48,000 Btu/h of cooling, and the rated capacities on the units in this category run from about 45,500 to 48,000 Btu/h depending on brand and series. It is the size that tends to get picked when a 3-ton unit is close but not quite enough: a small retail space with a lot of storefront glass, an office suite with a full conference room, a dental or medical suite with higher equipment loads, or any zone where ventilation air adds enough load to push past 3 tons. It is also a common replacement size on older strip centers and small office buildings where multiple packaged units each serve one tenant.
Every 4-ton packaged unit we carry is collected here, across gas/electric, cooling-only, and heat pump styles. If you would rather browse by configuration across all tonnages, use the Gas/Electric Rooftop Units, Heat Pump Rooftop Units, or Air Conditioner Rooftop Units pages.
When 4 Tons Makes Sense, and When It Doesn't
A load calculation is the only reliable way to size commercial equipment. As a loose check, light commercial space is often estimated in the range of 300 to 500 square feet per ton, which would suggest something like 1,200 to 2,000 square feet for a 4-ton unit. That range is wide on purpose. Occupant density, lighting and plug loads, solar exposure, and outdoor air requirements can move the real answer well outside it.
Some practical judgment calls at this size:
- Stepping up from 3 tons: If the old 3-ton unit ran constantly on design days but the space never had humidity issues, 4 tons may be correct. If the space was clammy and the old unit cycled a lot, the problem may be airflow, duct leakage, or controls, not capacity. Moving up a size will not fix that.
- Splitting the load: On a space that calculates near 8 tons, two 4-ton units on separate zones can sometimes give better control and redundancy than a single larger unit. That trade-off depends on roof layout, duct routing, and budget, and it is worth discussing with the engineer of record.
- Airflow: At a common design point of about 350 to 400 CFM per ton, a 4-ton unit is typically moving roughly 1,400 to 1,600 CFM. Retrofit duct systems sized for 3 tons often cannot handle that without excessive static pressure. Check the fan table on the spec sheet against measured or calculated external static.
Efficiency Metrics: SEER2 and EER2 Still Apply
A 4-ton unit is below 65,000 Btu/h, so it is rated with SEER2 and EER2, the same as the 3-ton and 5-ton units in this tree. That holds for single-phase and three-phase versions alike. IEER does not come into play until 6 tons and up.
Across the listings here, SEER2 ranges from 13.4 on the Daikin DP3, Daikin DFG, and Rheem RACCYB, RGECYB, and RHPCYB up to 16.8 on the Daikin DHH two-stage heat pump. Listed EER2 values run from 9.3 on the Comfortstar Star Pro CSV inverter heat pump up to 13 on the Daikin DHH. Note that the inverter Comfortstar posts a higher SEER2 than several fixed-speed units but a lower EER2, which is typical of variable-speed equipment: it shines at part load and gives up some steady-state efficiency at the hot rating point. If a utility program or spec sheet calls for a minimum EER2, check that number specifically.
Electrical Service Options
Four tons is still within the range where single-phase packaged equipment is readily available, which helps on small buildings without three-phase service. Voltages present on the 4-ton products in this category:
- 208/230V single-phase: Daikin DSG, DHG, DSC, DHC, DSH, and DHH; Rheem RACCYB; Comfortstar Star Pro CSV.
- 208/230V three-phase: Daikin D-series, DP3, and DFG; Rheem RACCYB, RGECYB, and RHPCYB.
- 460V three-phase: Daikin D-series and DFG; Rheem RACCYB, RGECYB, and RHPCYB.
- 575V three-phase: Daikin DSG, DHG, DSC, DHC, DSH, and DHH.
Single-phase 4-ton units draw more current per leg than their three-phase counterparts, so on a building with limited single-phase capacity, confirm that the panel and feeders can carry the minimum circuit ampacity listed for the specific model. We list MCA and maximum overcurrent protection on each product page; use those, not a generic breaker size, when you pull the electrical permit.
Gas Heat Inputs Available at 4 Tons
The heat input choice matters more than many people expect. Too little and the space falls behind on cold mornings; too much and you can exceed the heat exchanger's allowable temperature rise at the airflow your duct system actually delivers. Inputs offered on the 4-ton gas/electric listings here:
- Daikin DSG: 70,000, 80,000, 90,000, 100,000, and 115,000 Btu/h
- Daikin DHG: 70,000, 80,000, 100,000, 115,000, and 140,000 Btu/h
- Daikin DP3: 80,000 Btu/h, standard (DP3GM) and ultra low NOx (DP3UM)
- Daikin DFG (R-410A): 70,000, 90,000, and 115,000 Btu/h
- Rheem RGECYB: 75,000 and 120,000 Btu/h
Ultra low NOx versions of several Daikin DSG and DHG models are listed here for areas where local air quality rules limit NOx emissions from gas-fired equipment. Your local air district or code official determines whether that applies. For cooling-only and heat pump units that need supplemental or emergency heat, match an electric heat kit to the exact model on the Commercial Electric Heat Kits page.
A2L Refrigerants on Current 4-Ton Equipment
The Daikin D-series, Daikin DP3, and Comfortstar units use R-32. The Rheem RACCYB, RGECYB, and RHPCYB use R-454B. Both are A2L refrigerants, meaning lower global warming potential and a mild flammability classification. Installation and service should follow the manufacturer's instructions and your adopted mechanical code, using tools rated for A2L work and technicians trained on A2L procedures. Requirements for refrigerant detection, charge limits, and service clearances can vary by model and jurisdiction, so read the installation manual before startup rather than after. The Daikin DFG listings are R-410A, which can simplify a replacement on a site where the owner's maintenance program is still built around R-410A, subject to availability.
Curb Fit and Rigging
Four-ton units often share a cabinet with the 3-ton or 5-ton model of the same series, but not always, and cabinet sizes differ between brands. Before you schedule the lift:
- Pull the curb drawing for the exact model and compare footprint, height, and duct openings to what is on the roof.
- If you are changing brands, assume you will need a curb adapter until the drawings prove otherwise.
- Confirm unit weight against the roof structure and the crane's reach and capacity at the set point. Weights are on each product page.
- Check that gas, electrical, and condensate connections line up with existing rooftop runs, or budget for rerouting.
Curbs, adapters, economizers, and related hardware are on the Rooftop Unit Accessories page.
Economizer and Outdoor Air Considerations
Economizer requirements under ASHRAE 90.1 and the IECC depend on climate zone and cooling capacity, and a 4-ton unit sits close to the threshold where some code editions begin to require one. Do not assume either way. Check the code edition and amendments your jurisdiction has adopted, and the mechanical plans if the job is engineered. Where an economizer is installed, use the accessory designed for that series so that controls, damper fit, and sensor wiring work as intended.
Comparing the 4-Ton Units We Carry
| Brand | Series | Type | Voltages Listed | Efficiency (as listed) | Refrigerant |
|---|---|---|---|---|---|
| Daikin | DSG | Gas/Electric, single-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 13.7 to 14 SEER2 / 11 EER2 | R-32 |
| Daikin | DHG | Gas/Electric, two-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 16.4 SEER2 / 12 EER2 | R-32 |
| Daikin | DSC | Air Conditioner, single-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 13.7 SEER2 / 11 EER2 | R-32 |
| Daikin | DHC | Air Conditioner, two-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 16.4 SEER2 / 12 EER2 | R-32 |
| Daikin | DSH | Heat Pump, single-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 13.7 SEER2 / 11 EER2 | R-32 |
| Daikin | DHH | Heat Pump, two-stage | 208/230V-1, 208/230V-3, 460V-3, 575V-3 | 16.8 SEER2 / 13 EER2 | R-32 |
| Daikin | DP3 (DP3GM, DP3UM, DP3HM) | Gas/Electric and Heat Pump | 208/230V-3 | 13.4 SEER2 / 10 EER2 | R-32 |
| Daikin | DFG | Gas/Electric, multi-position | 208/230V-3, 460V-3 | 13.4 SEER2 / 11 EER2 (confirm on spec sheet) | R-410A |
| Rheem | RACCYB | Air Conditioner | 208/230V-1, 208/230V-3, 460V-3 | 13.4 SEER2 / 10 EER2 | R-454B |
| Rheem | RGECYB | Gas/Electric | 208/230V-3, 460V-3 | 13.4 SEER2 / 10 EER2 | R-454B |
| Rheem | RHPCYB | Heat Pump | 208/230V-3, 460V-3 | 13.4 SEER2 / 10 EER2 | R-454B |
| Comfortstar | Star Pro CSV | Inverter Heat Pump | 208/230V-1 | 14.6 SEER2 / 9.3 EER2 | R-32 |
These figures come from the product listings on this page. Before you submit, confirm the rating for the exact model number on the manufacturer's spec sheet or AHRI certificate, especially if a rebate, bid specification, or code compliance form depends on it.
Picking a Series
Work through it in order: available power, heating source, then efficiency. On three-phase budget replacements, the Daikin DP3 and the Rheem CYB units are the simplest path. If the owner pays the utility bill and plans to keep the building, or if part-load humidity control matters, price the two-stage Daikin DHG, DHC, or DHH. For a single-phase building, look at the single-phase Daikin D-series models, the Rheem RACCYB, or the Comfortstar Star Pro CSV inverter heat pump. If the calculation lands close to 5 tons, compare against the 5 Ton Rooftop Units page; if it is closer to 3, the 3 Ton Rooftop Units page has the same series one size down.
Before You Place the Order
- Give us the complete model number. Voltage, heat input, and NOx option are part of the model code and determine what actually ships.
- Bundle the curb or curb adapter, economizer, and controls with the unit order so the install crew is not waiting on parts.
- Arrange freight receiving with a dock or liftgate, and note any visible damage on the delivery receipt before signing.
- Availability varies by series, voltage, and time of year. Ask about stock on 460V and 575V models before committing to an install date.
Frequently Asked Questions
Can a 4-ton rooftop unit replace a 3-ton unit on the same curb?
Sometimes. Some series use the same cabinet for both sizes, others do not. Compare the curb drawing for the new 4-ton model to the existing curb, and also confirm that the existing ductwork can handle the higher airflow.
Which 4-ton units here are inverter or variable-speed?
The Comfortstar Star Pro CSV is listed as an inverter heat pump. The Daikin DHG, DHC, and DHH are two-stage, and the remaining series are single-stage per their listings.
Is there a 4-ton unit with 140,000 Btu/h gas heat?
Yes. The Daikin DHG series is listed with a 140,000 Btu/h input option at 4 tons. Check that the temperature rise stays within the allowed range at your design airflow.
Why does the inverter heat pump have a lower EER2 than some fixed-speed units?
EER2 is measured at a single hot outdoor condition. Variable-speed equipment typically gains most of its advantage at part load, which shows up in SEER2 rather than EER2.
Do these 4-ton units need special tools for A2L refrigerant?
The R-32 and R-454B units should be serviced with recovery equipment, vacuum pumps, and leak detectors rated for A2L refrigerants, by technicians trained on A2L procedures. Follow the manufacturer's installation manual and local code.
Are 575V models available at 4 tons?
Yes, the Daikin DSG, DHG, DSC, DHC, DSH, and DHH series are listed in 575V three-phase at this size. Lead times on 575V can be longer, so confirm availability early.