Tempstar
Tempstar 4 Ton 48,000 BTU 14 SEER2 Single-Stage Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF048L02A0AAA
SKU: RAF048L02A0AAA
$9,287.17- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Tempstar
Tempstar 5 Ton 57,500 BTU 14 SEER2 Single-Stage Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF060L02A0AAA
SKU: RAF060L02A0AAA
$10,252.17- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Tempstar
Tempstar 3 Ton 34,400 BTU 14 SEER2 Single-Stage Horizontal / Vertical Air Conditioner Package Unit, 230V 3-Phase, R-454B | RAF036H02A0AAA
SKU: RAF036H02A0AAA
$7,455.20- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days13 in stock -
Tempstar
Tempstar 6 Ton 70,000 BTU 14 SEER2 Two-Stage Commercial Horizontal / Vertical Air Conditioner Package Unit, 230V 3-Phase, R-454B | RAF072H02A0AAA
SKU: RAF072H02A0AAA
$11,307.48- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days23 in stock -
Tempstar
Tempstar 3 Ton 34,400 BTU 14 SEER2 Single-Stage Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF036L02A0AAA
SKU: RAF036L02A0AAA
$7,617.32- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days2 in stock -
Tempstar
Tempstar 15 Ton 174,000 BTU Two-Stage Commercial Horizontal / Vertical Air Conditioner Package Unit, 208/230V 3-Phase, R-454B | RAF180H02A0AAA
SKU: RAF180H02A0AAA
$31,464.72- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days2 in stock -
Tempstar
Tempstar 7.5 Ton 86,000 BTU Commercial Horizontal / Vertical Air Conditioner Package Unit, 208/230V 3-Phase, R-454B | RAF090H02A0AAA
SKU: RAF090H02A0AAA
$17,630.93- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 1-2 Business Days22 in stock -
Tempstar
Tempstar 10 Ton 120,000 BTU Commercial Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF120L02A0AAA
SKU: RAF120L02A0AAA
$23,688.82- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days7 in stock -
Tempstar
Tempstar 7.5 Ton 86,000 BTU Commercial Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF090L02A0AAA
SKU: RAF090L02A0AAA
$18,026.20- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business DaysOnly 1 in stock -
Tempstar
Tempstar 8.5 Ton 98,000 BTU Commercial Horizontal / Vertical Air Conditioner Package Unit, 208/230V 3-Phase, R-454B | RAF102H02A0AAA
SKU: RAF102H02A0AAA
$20,864.83- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Tempstar
Tempstar 3.5 Ton 42,000 BTU Convertible Air Conditioner Package Unit, 230V 3-Phase, R-454B | PAB442000H000B
SKU: PAB442000H000B
$8,406.27- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business DaysOnly 1 in stock -
Tempstar
Tempstar 15 Ton 174,000 BTU Commercial Horizontal / Vertical Air Conditioner Package Unit, 460V 3-Phase, R-454B | RAF180L02A0AAA
SKU: RAF180L02A0AAA
$31,887.23- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business DaysOnly 1 in stock
Air Conditioner Rooftop Units
Cooling-Only Rooftop Units and When to Add Electric Heat
Air conditioner rooftop units are packaged units built for cooling, with no gas section and no reversing valve. They cover two very common situations: buildings where heat is handled by something else, and buildings in warm climates where a modest electric heat kit in the unit is enough for the few cold mornings each year. This category carries cooling-only packaged units from 3 to 25 tons from Daikin, Rheem, and Comfortstar. If the space needs substantial heat, compare the options in Gas/Electric Rooftop Units and Heat Pump Rooftop Units before settling on a cooling-only unit with large strip heat.
What Is in This Category
| Brand and series | Tonnage range listed | Refrigerant | Electrical options listed | Listed efficiency |
|---|---|---|---|---|
| Daikin DSC | 3 to 25 tons | R-32 | 208/230V-1 (3 to 5 tons), 208/230V-3, 460V-3, 575V-3 | 13.7 to 14 SEER2; 13.2 to 16.7 IEER |
| Daikin DHC | 3 to 12.5 tons | R-32 | 208/230V-1 (3 to 5 tons), 208/230V-3, 460V-3, 575V-3 | 16.2 to 16.6 SEER2; 16 to 18.6 IEER |
| Rheem RACCYB | 3 to 5 tons | R-454B | 208/230V-1, 208/230V-3, 460V-3 | 13.4 SEER2 |
| Rheem RACDYB | 7.5 to 12.5 tons | R-454B | 208/230V-3, 460V-3 | 11.0 to 11.2 EER; 14.2 to 14.8 IEER |
| Rheem RACGYB | 15 and 20 tons | R-454B | 208/230V-3, 460V-3 | 11.0 EER |
| Comfortstar Freedom CRT7 | 7.5 to 12.5 tons | R-454B | 208/230V-3 | 11.2 to 11.6 EER |
If you are matching a 25 ton cooling-only unit, the Daikin DSC line is where to look in this category. For 575V service, Daikin DSC and DHC are the options listed.
Where Cooling-Only Units Make Sense
- Hot, cooling-dominated climates. In South Florida, the Gulf Coast, and the desert Southwest, many buildings need only enough heat to take the edge off a cold front. A cooling-only unit with a small electric heat kit is often simpler and less expensive than a gas/electric unit.
- Heat comes from elsewhere. Buildings with perimeter hydronic heat, unit heaters in a warehouse, or a separate heating system for the zone only need cooling from the rooftop unit.
- Interior zones and high internal loads. Interior spaces surrounded by conditioned areas, server and equipment rooms, and spaces with heavy lighting, cooking, or process loads may need cooling most of the year and little or no heat.
- No gas on the roof, cooling is the priority. Where gas is not available and the heating load is small, a cooling-only unit with electric heat can be the most direct replacement.
Where it is the wrong tool: buildings with real heating loads in cold or mixed climates. Electric resistance heat delivers one unit of heat for each unit of electricity, while a heat pump typically delivers more than one, and gas heat avoids the large electrical demand entirely. If an owner is facing a sizable winter heating load, compare a heat pump or gas/electric unit before specifying a large heat kit.
Pairing Optional Electric Heat
Electric heat kits for packaged units are listed in the Commercial HVAC category. Each is specific to a unit family, voltage, and phase; the product title tells you what it fits. Daikin, Rheem, and Comfortstar kits are all represented. When you add heat to a cooling-only unit:
- Size it to the heating load, including the outside air the unit brings in. In cooling-dominated climates, the design heating load is often small, so avoid defaulting to the largest kit.
- Confirm the kit is approved for that exact unit, and note any airflow requirements in the installation manual. Electric heat needs adequate airflow across the elements.
- Recalculate the electrical circuit. The minimum circuit ampacity and maximum overcurrent protection change when a heat kit is installed. A circuit sized for cooling only may not carry the unit plus heat.
- Stage the heat. Larger kits are typically wired in more than one stage. Use a thermostat or controller that stages heat to limit demand peaks.
Many kits are field installed after the unit is set. Order the kit with the unit so it is on site when the electrician makes the final connections.
Efficiency: Reading the Ratings
Smaller units, under 65,000 Btu/h, are rated in SEER2. Larger units are rated in EER, which describes full-load efficiency, and IEER, which weights part-load performance across several conditions. Cooling-only rooftop units tend to run long hours, so in a hot climate, efficiency differences show up on the utility bill. As an example of the spread here, the Daikin DHC line is listed up to 18.6 IEER, while some larger units are listed by EER only. Where both are published, IEER is generally the more useful number for estimating annual energy use on a commercial building, and EER is the figure to look at when peak demand matters.
Efficiency ratings and the AHRI certificate also matter for utility incentive programs and for code compliance. If a rebate depends on a specific efficiency level, confirm the AHRI listing for the exact model before ordering.
Humidity and Comfort in Warm Climates
Cooling-only units in humid climates do much of their work removing moisture. An oversized unit cools the space quickly and shuts off before it has removed enough moisture, leaving the space cool and clammy. Right-size the unit to the load, pay attention to the fan settings during commissioning, and look at the manufacturer's options for multi-stage or variable capacity operation and dehumidification controls where humidity is a concern. Outside air is a major moisture load in humid areas, so the economizer and ventilation controls should be set up with that in mind.
Coastal and Corrosive Sites
Rooftop equipment near salt water takes a beating. Coil corrosion is the most common cause of early failure on coastal rooftops. If the unit will sit within sight of the ocean or downwind of industrial exhaust, ask about the manufacturer's coated or corrosion-resistant coil options and plan regular coil rinsing as part of maintenance.
Refrigerant and Installation Notes
Daikin cooling-only units here use R-32, and the Rheem and Comfortstar units use R-454B. Both are A2L refrigerants, so technicians should use A2L-rated equipment and follow the manufacturer's installation instructions for leak detection and mitigation. Economizers are required on many units above a certain capacity under energy codes based on ASHRAE 90.1 and the IECC, depending on climate zone. Model-specific economizers, curbs, and curb adapters are listed in Commercial HVAC.
Matching an Existing Cooling-Only Unit
On a straight replacement, start with the old nameplate: nominal tonnage, voltage and phase, and whether a heat kit is installed and what size it is. Open the access panel and check; heat kits are often field installed and may not appear in the model number. Note whether the airflow is downflow through the curb or horizontal, since several of the smaller units here are listed as convertible. Then compare curb dimensions and duct openings, and confirm the new unit plus any heat kit fits the existing circuit. If the old unit had no heat and the tenant now wants some, treat that as a new electrical load and get the electrician involved before ordering.
Frequently Asked Questions
Can I add heat to a cooling-only rooftop unit?
Yes, with an electric heat kit approved for that unit family, voltage, and phase. Recalculate the circuit with the heat kit installed before ordering.
Is a cooling-only RTU a good choice in Florida?
Often, yes. Many buildings in South Florida need very little heat, and a cooling-only unit with a small heat kit covers the occasional cold morning. Size the unit carefully for humidity control.
What is the difference between this and a heat pump rooftop unit?
A heat pump reverses its refrigeration cycle to heat; a cooling-only unit relies on electric resistance heat if heat is needed. Heat pumps are more efficient at heating but cost more upfront.
Which units here are available in 575V?
Daikin DSC and DHC models are listed in 575V three-phase. The Rheem and Comfortstar units in this category are listed in 208/230V and, for Rheem, 460V.
Why do some larger units show EER but not IEER?
The product title shows what the listing includes; the manufacturer spec sheet and AHRI certificate carry the full set of ratings. Check those documents when you need both values.
Do I need a new curb for a cooling-only replacement?
Not necessarily. Compare the new unit's curb drawing with the existing curb. If they do not match, a curb adapter for that specific combination may avoid reroofing.