$239.38
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$244.02
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$508.58
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$215.24
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$244.02
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$733.69
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days6 in stock -
$742.53
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$226.02
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$733.69
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business DaysOnly 1 in stock -
$840.53
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$1,415.13
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Propane (LP) Conversion Kit (Gas Only) for 3-6 Ton Units | LPHE-036072
SKU: LPHE-036072
$92.84- 📦$14.95 Flat-Rate Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days223 in stock
Blower, Vent & Conversion Kits
Field Kits That Adapt a Packaged Unit to the Site: Static, Fuel, Altitude and Venting
A packaged rooftop unit leaves the factory configured for typical conditions: natural gas, near sea level, moderate duct static and a standard flue outlet. Real jobs do not always look like that. The duct system was designed for a bigger fan, the building is on propane, the site is at elevation, or the flue discharge ends up too close to an outdoor air intake. This category holds the Daikin field kits that change the unit's configuration to fit the site. All are genuine Daikin field-installed accessories, matched by cabinet and tonnage.
What Is in This Category
- High static blower kits for 3, 4 and 5 ton Daikin packaged units, in HSKT (B series, marked 230/460V) and HSKTS part families, with -7 suffix versions listed for each size; and the HSKTW120-7 high static belt drive assembly for 10 ton units.
- Propane (LP) conversion kits: LPHE-036072 for 3 to 6 ton units, LPHE-090150 for 7.5 to 12.5 ton units, and LPKT180300A and LPKT180300DFG for 15 to 25 ton units.
- High altitude kits: HA036300 and HA180300DFG (gas only, 15 to 25 ton).
- Vent flue extensions: 220-GX-01 for 3 to 6 ton, 220-GX-02 for 7.5 to 12.5 ton and 220-GX-03 for 15 to 20 ton gas/electric units.
- Freeze protection kit: FSK04A for 7.5 to 10 ton units. The FSK02A and FSK03A freeze protection thermostat kits are listed under Commercial HVAC Controls and Sensors.
Several part numbers differ only by a suffix or a final letter group, such as HSKT036B versus HSKT036B-7, or LPKT180300A versus LPKT180300DFG. Treat the full part number as significant and confirm it against the unit's accessory table or ask us before ordering.
High Static Kits: When the Duct System Wins
Every packaged unit has a blower performance table showing how much air it moves at each external static pressure with the standard drive. When the measured or calculated static exceeds what the standard drive can handle at design airflow, the unit runs short on air. That shows up as low capacity, frozen coils in cooling, high-limit trips in heating, and noisy, overworked motors. Common causes on commercial jobs are long duct runs, undersized return paths, high-efficiency filters, economizers and outdoor air hoods, and electric heat or hot water coils added downstream.
A high static kit changes the blower drive so the unit can deliver its rated airflow against higher external static pressure. Before ordering one:
- Measure total external static pressure across the unit with the filters, coil and accessories in place.
- Compare against the unit's blower table at the airflow the design calls for.
- Look for fixes in the duct system first: crushed flex, closed dampers, a blocked return or a dirty coil. A high static kit adds fan energy; it should not cover up a correctable restriction.
- If the duct system is what it is, select the kit for the unit tonnage and confirm the version against the unit voltage and model number.
After installation, reset the drive per the kit instructions, measure airflow and amp draw, and record the new settings.
Propane Conversion
Daikin gas/electric packaged units ship set up for natural gas. On a site served by propane, the gas heat section has to be converted before the first firing. LP conversion kits change the parts that set the fuel-specific firing rate and pressure regulation, and the kit instructions spell out the procedure and the manifold pressure to set. Conversion is a qualified-technician job: follow the kit instructions exactly, check for leaks, set and verify manifold pressure with a manometer, check the flame and combustion, and apply the conversion label if one is supplied so the unit's fuel is obvious to anyone who services it later.
Pick the kit by cabinet: LPHE-036072 for 3 to 6 tons, LPHE-090150 for 7.5 to 12.5 tons, and for 15 to 25 tons either LPKT180300A or LPKT180300DFG depending on the unit family. Confirm the 15 to 25 ton match on the product page or with us before ordering.
High Altitude
Air is thinner at elevation, so a gas burner set up for sea level runs rich and can produce poor combustion. Manufacturers publish the elevation above which their gas heat must be derated or re-orificed, and local fuel gas codes require following those instructions. The high altitude kits here adjust the gas heat section for higher elevations. Use the unit installation manual to determine whether your elevation needs the kit and what input and manifold settings apply. HA180300DFG is for 15 to 25 ton gas units; HA036300 covers a range of Daikin packaged units listed on its product page.
Where a site is both on propane and at elevation, both changes apply. Read both sets of instructions before starting and follow the order they give.
Vent Flue Extensions
Packaged gas units vent combustion products through a flue outlet on the cabinet. Fuel gas codes and the manufacturer's instructions require that outlet to keep specified clearances from outdoor air intakes, operable openings, adjacent walls and expected snow levels. When a unit is placed near a parapet, a neighboring unit's economizer hood or a building air intake, or in snow country, the standard outlet may not meet those clearances. The 220-GX vent flue extensions raise or relocate the discharge for 3 to 6, 7.5 to 12.5 and 15 to 20 ton Daikin gas/electric units. Check the unit layout and the required clearances on the drawings or at the site walk before the unit is set.
Freeze Protection for Low-Load Cooling
Units serving spaces with low cooling loads, high outdoor air at mild temperatures, or long runtimes at night can drive the indoor coil cold enough to ice. The FSK04A freeze protection kit for 7.5 to 10 ton units protects the indoor coil from freezing during low-load cooling operation, which prevents the airflow loss and water damage that a frozen coil causes. Smaller units use the FSK02A and FSK03A thermostat kits listed under Commercial HVAC Controls and Sensors.
Installation Sequencing
- Decide on fuel, elevation, venting and static before the unit ships; some of these kits are easier to install on the ground or on the curb before final connections.
- Install the high static kit before airflow balancing, since it changes the blower.
- Complete LP conversion and high altitude adjustments before the first heating start-up.
- Install the vent extension before firing the burner.
- Record every change on the unit and in the start-up report.
Ordering Tips
Send the unit model number, fuel type, site elevation, measured or design external static pressure and unit voltage. For 15 to 25 ton units, tell us the unit family so the LP and high altitude kits match. The same unit's curb, economizer and filter accessories are under Rooftop Unit Accessories.
Frequently Asked Questions
Can I convert a gas/electric rooftop unit to propane in the field?
Yes, with the manufacturer's LP conversion kit for that cabinet, installed by a qualified technician following the kit instructions, including manifold pressure setting and labeling.
At what elevation do I need a high altitude kit?
It depends on the unit. The installation manual gives the elevation threshold and the required adjustments. Follow those values and your local fuel gas code.
How do I know if a high static kit will fix low airflow?
Measure external static pressure and compare it with the blower table. If the standard drive cannot reach design airflow at the measured static, and the duct restriction cannot be corrected, a high static kit is the right step.
What is the difference between HSKT and HSKTS kits?
They are separate Daikin kit families for different unit models. Use the unit's accessory table or ask us to match the model number.
Why would I need a vent flue extension?
To keep the flue discharge the required distance from air intakes, openings, walls and snow, as the manufacturer and fuel gas code require.
Does the freeze protection kit replace proper airflow?
No. It protects the coil when load is low. A unit with low airflow needs the airflow problem fixed first.