Daikin
Daikin Downflow Economizer, JADE Controls for 7.5-12.5 Ton Packaged Rooftop Units | DDNECNJ90150NR
SKU: DDNECNJ90150NR
$3,848.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Downflow Economizer for 7.5-12.5 Ton Packaged Rooftop Units | DDNECNJ90150
SKU: DDNECNJ90150
$4,612.27- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days9 in stock -
Daikin
Daikin Downflow Economizer, Low Leakage for 7.5-12.5 Ton Packaged Rooftop Units | DDNECNJ90150B
SKU: DDNECNJ90150B
$4,661.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Downflow Economizer for 15-20 Ton Packaged Rooftop Units | DDNECNJ180240
SKU: DDNECNJ180240
$3,187.93- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$510.42
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$1,943.91
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Modulating Enthalpy Economizer Kit with MERV 8 Filter for FXMQ/FBQ 12P Ducted Units | ECONMQ12P-8-1K
SKU: ECONMQ12P-8-1K
$3,707.51- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Modulating Enthalpy Economizer Kit with MERV 8 Filter for FXMQ18-30P / FBQ18-30P Ducted Units | ECONMQ30P-8-1K
SKU: ECONMQ30P-8-1K
$3,964.27- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Modulating Enthalpy Economizer Kit with MERV 8 Filter for FXMQ36-48P / FBQ36-48P Ducted Units | ECONMQ48P-8-1K
SKU: ECONMQ48P-8-1K
$4,242.42- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Modulating Enthalpy Economizer Kit with MERV 13 Filter for FXMQ/FBQ 12P Ducted Units | ECONMQ12P-13-1K
SKU: ECONMQ12P-13-1K
$4,257.69- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Modulating Enthalpy Economizer Kit with MERV 13 Filter for FXMQ18-30P / FBQ18-30P Ducted Units | ECONMQ30P-13-1K
SKU: ECONMQ30P-13-1K
$4,471.62- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Downflow Economizer with JADE Controls for Daikin H Series Packaged Units | DDNECNJPCHHA
SKU: DDNECNJPCHHA
$4,480.80- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock
Rooftop Unit Economizers
Commercial Economizer Selection by Unit Series, Controller and Leakage Class
On a commercial rooftop job the economizer decision is rarely "economizer or no economizer." The ventilation design, the energy code adopted where the building sits, and the owner's control system have usually settled that. The real work is ordering the specific economizer that fits the unit model, matches its duct configuration, carries the right controller and sensor package, and meets any damper leakage requirement in the specifications. This category is set up for that part of the job.
It covers field-installed economizers for Daikin light commercial packaged units from 3 to 25 tons, Rheem C and D-cabinet commercial packaged units including DDC versions, Carrier 50FEQ and American Standard packaged units, and modulating enthalpy economizer kits for Daikin FXMQ VRV and SkyAir FBQ ducted indoor units. It also carries the sensors and upgrade kits that change how an installed economizer decides when to use outdoor air.
What Is in This Category
- Daikin downflow economizers for DCC/DCG/DCH 036-072 and 090-150 units and 180-240 units, in standard, low leakage and JADE-controller versions; downflow economizers for Daikin M Series AC, heat pump and gas/electric units and H Series units; and a 15 to 25 ton downflow JADE economizer with enthalpy sensor for DBC, DBG and DBH units.
- Daikin horizontal economizers, including a range of 7.5 to 12.5 ton ultra low-leak horizontal economizers with JADE dry bulb sensing, some listed specifically for DBC and DBG units.
- Daikin VRV and SkyAir ducted unit kits: ECONMQ modulating enthalpy economizer kits for FXMQ and FBQ ducted units in 12P, 18-30P and 36-48P sizes, each offered with a MERV 8 or MERV 13 filter, plus a wall-mount CO2 sensor and a comparative enthalpy sensor for those kits.
- Rheem economizers with single enthalpy control for C (3 to 6 ton) and D (7.5 to 12.5 ton) cabinets, in downflow, downflow/vertical and horizontal versions, standard and DDC; Siemens-controlled horizontal versions; and a convertible economizer for RHPXYC units.
- Rheem upgrade parts: dual enthalpy kits in DDC and non-DDC versions and a Siemens QFR temperature and humidity sensor for dual enthalpy.
- Carrier and American Standard: a low-leak economizer for Carrier 50FEQ and an American Standard economizer for its listed series.
- A Daikin internal filter rack for M Series gas/electric units fitted with an economizer.
Match the Economizer to the Unit, Step by Step
- Unit family and cabinet. Start with the full model number. For Daikin, the family prefix and capacity code (036-072, 090-150, 180-240, 180-300) point to the right economizer family; for Rheem, the C or D cabinet letter does. M Series, H Series and DB-family Daikin units have their own economizers, so do not cross them over to DC-family units of the same tonnage.
- Duct configuration. Downflow and horizontal economizers are different assemblies. A unit converted from downflow to horizontal in the field needs the horizontal economizer. The Rheem downflow/vertical and the RHPXYC convertible versions are the exceptions to check for.
- Controller and changeover sensing. Decide between dry bulb, single enthalpy, comparative (dual) enthalpy, and the controller platform: JADE, Siemens, or a DDC version that hands control to the unit's communicating board or the building automation system.
- Leakage class. If the specifications or the energy code call for low-leakage outdoor air dampers, choose a low leakage or ultra low-leak model and keep the documentation for the inspector.
- Relief. Plan where the extra outdoor air leaves the building. That is covered on the Rooftop Unit Power Exhaust page.
Choosing the Changeover Control for the Climate
The economizer's high-limit control decides when outdoor air is good enough to cool with. Dry bulb control compares temperature only. Single enthalpy control looks at outdoor temperature and humidity together. Comparative, or dual, enthalpy compares outdoor air against return air and uses whichever carries less heat. In dry climates, dry bulb sensing is usually adequate. In humid climates, including most of the Southeast and Gulf Coast, temperature alone can bring in air that is cool but wet, which loads the coil and raises indoor humidity. That is where enthalpy sensing earns its cost.
Energy codes such as ASHRAE 90.1 and the IECC regulate which high-limit control types are allowed in each climate zone and set the limits for them. The tables change between editions, so use the edition your jurisdiction has adopted and the project specifications rather than a rule of thumb. If an installed Rheem economizer needs to move from single to dual enthalpy, the dual enthalpy kits and Siemens QFR sensor in this category are the field upgrade path; pick the DDC or non-DDC kit to match the economizer you have.
JADE, Siemens and DDC Versions
Controller choice affects commissioning and service more than first cost. JADE-controlled Daikin economizers use a controller with an on-board display and setup menus, and they report sensor and damper faults. Recent editions of the major energy codes include economizer fault detection and diagnostics requirements for many units, and controllers of this type are designed with that in mind; confirm what your code edition requires. The Rheem Siemens-controlled versions use Siemens actuators and sensors. DDC versions are built to be controlled by the unit's communicating controls or a building automation system, which is the right choice when the owner wants economizer status and commands on the BAS.
Economizers for Daikin VRV and SkyAir Ducted Units
The ECONMQ kits are not rooftop accessories. They attach to Daikin FXMQ (VRV) and FBQ (SkyAir) ducted indoor units and give a split or VRF system modulating outdoor air dampers with enthalpy-based free cooling. Choose by indoor unit size group (12P, 18-30P or 36-48P), then by filter: MERV 8 for general filtration, MERV 13 where the project calls for higher filtration. Check the static pressure impact of the filter and outdoor air ductwork against the indoor unit's external static rating. The wall-mount CO2 sensor supports demand-based ventilation with these kits, and the comparative enthalpy sensor adds return air comparison.
Installation and Commissioning Notes
- Install with power locked out and follow the unit-specific instructions; economizers plug into the unit's control harness, and harness and board revisions matter.
- Mount outdoor sensors out of direct sun and away from exhaust and relief discharge.
- Set minimum position from the ventilation design airflow, measured, not guessed.
- Set the high-limit changeover to the code-required value for the climate zone.
- Verify the damper strokes fully in both directions and that relief operates when the economizer opens.
- Record settings on the unit so the service tech has them.
Ordering Tips
Send the full unit model number, duct configuration, preferred controller (JADE, Siemens, DDC or standard) and any specified leakage class. Several Daikin 7.5 to 12.5 ton ultra low-leak horizontal part numbers look alike but are listed for different unit families, so let us confirm the match. Fresh Air Dampers is the sibling category to use when the job needs fixed ventilation air without free cooling.
Frequently Asked Questions
What is the difference between low leakage and ultra low-leak?
Both describe outdoor and return damper leakage when closed, with ultra low-leak being tighter. Codes and specifications may require a maximum leakage rate; check the product data against what the project calls for.
Should I buy a DDC economizer?
Choose DDC when the unit uses communicating controls or the building automation system will command the economizer. On a stand-alone unit with a conventional thermostat, the standard version is usually the fit.
Can I add an economizer to a Daikin FXMQ VRV ducted unit?
Yes, with the ECONMQ kit sized for that indoor unit. Pick MERV 8 or MERV 13 and add the CO2 sensor if the ventilation design uses demand control.
Can I upgrade a single enthalpy Rheem economizer to dual enthalpy?
Rheem offers dual enthalpy kits for this, in DDC and non-DDC versions. Match the kit to your economizer's control type.
Are Daikin M Series economizers different for gas/electric units?
Yes. Separate economizers are listed for M Series AC and heat pump units and for gas/electric units, and an internal filter rack is offered for gas/electric units with an economizer.
Does the economizer need power exhaust?
It needs some form of relief. Barometric relief works on many buildings; powered exhaust is used when the return path cannot relieve enough air. See Rooftop Unit Power Exhaust.