Daikin
Daikin 18-Inch Knockdown Roof Curb for 15-25 Ton Packaged Rooftop Units | 18CURB180300
SKU: 18CURB180300
$2,140.02- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days10 in stock -
Daikin
Daikin 14-Inch Knockdown Roof Curb for 15-25 Ton Packaged Rooftop Units | 14CURB180300
SKU: 14CURB180300
$2,182.87- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days61 in stock -
Daikin
Daikin 24-Inch Knockdown Roof Curb for 15-25 Ton Packaged Rooftop Units | 24CURB180300
SKU: 24CURB180300
$3,070.78- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, End Discharge, Roofed-In, for 15-25 Ton Packaged Rooftop Units | HZCURB180300EDR
SKU: HZCURB180300EDR
$6,136.78- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, End Discharge, Slab Mount, for 15-25 Ton Packaged Rooftop Units | HZCURB180300EDS
SKU: HZCURB180300EDS
$6,136.78- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, Non-Service Side Discharge, Roofed-In, for 15-25 Ton Packaged Rooftop Units | HZCURB180300NSR
SKU: HZCURB180300NSR
$7,434.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, Non-Service Side Discharge, Slab Mount, for 15-25 Ton Packaged Rooftop Units | HZCURB180300NSS
SKU: HZCURB180300NSS
$7,434.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, Service Side Discharge, Roofed-In, for 15-25 Ton Packaged Rooftop Units | HZCURB180300SSR
SKU: HZCURB180300SSR
$7,434.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin Horizontal Roof Curb, Service Side Discharge, Slab Mount, for 15-25 Ton Packaged Rooftop Units | HZCURB180300SSS
SKU: HZCURB180300SSS
$7,434.13- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Daikin
Daikin 16-Inch Downflow Square-to-Round Duct Adapter for PCCP101-103 Roof Curb Packaged Units | SQRPC101
SKU: SQRPC101
$715.22- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
$1,393.76
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days3 in stock -
Goodman
Goodman 14 Inch Knockdown Roof Curb for M Series 2-5 Ton Packaged Units | D14CRBPGCHMA
SKU: D14CRBPGCHMA
$787.93- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships in 2-3 Business Days23 in stock
Rooftop Unit Roof Curbs
Ordering the Right Roof Curb Part Number for a Commercial Packaged Unit
A roof curb is the one rooftop accessory that has to be right before anything else happens. It is installed and flashed into the roof ahead of the unit, it fixes the supply and return duct locations, and it determines how high the equipment sits above the membrane. Get the part number wrong and the unit does not land, the ducts do not line up, or the roofer has to come back. This category is built for ordering the correct curb the first time on commercial packaged unit projects.
The curbs here are manufacturer-matched for Daikin light commercial packaged units from 3 to 25 tons, the Rheem C cabinet, the Carrier 50FEQ series and American Standard packaged units. They include Daikin knockdown downflow curbs in 14, 18 and 24-inch heights and Daikin horizontal curbs for 15 to 25 ton units in several discharge arrangements.
What Is in This Category
- Daikin knockdown downflow curbs – 14CURB, 18CURB and 24CURB part numbers for the 3672B (3 to 6 ton), 90150 (7.5 to 12.5 ton), 180240 (15 to 20 ton) and 180300 (15 to 25 ton) cabinets. Not every height is offered for every cabinet; the 180240 cabinet is listed here in 14-inch.
- Daikin horizontal curbs – HZCURB part numbers for 15 to 20 and 15 to 25 ton units, in end discharge, service-side discharge and non-service-side discharge layouts. The 180300 versions come in roofed-in and slab-mount configurations.
- Rheem – RXKG-DCC14, a 14-inch curb for 3 to 6 ton C-cabinet units.
- Carrier and American Standard – a 6 ton curb for Carrier 50FEQ packaged units and a 6 ton curb for American Standard RHCPY series packaged units.
- Duct adapter – a Daikin 16-inch downflow square-to-round adapter for curb-mounted PCCP packaged units. More adapters are under Filter Racks and Duct Adapters.
Step 1: Identify the Unit Family and Capacity Code
Curbs are designed to a cabinet footprint, and the footprint follows the model family as much as the tonnage. On Daikin equipment, read the three-digit capacity code in the model number (036 through 300, in thousands of Btu/h) together with the family prefix:
| Daikin unit family and size | Curb cabinet code | Downflow heights listed |
|---|---|---|
| DCC/DCG/DCH 036-072 (3 to 6 tons) | 3672B | 14, 18 and 24 inch |
| DCC/DCG/DCH 090-150 (7.5 to 12.5 tons) | 90150 | 14, 18 and 24 inch |
| DCC/DCG 180-240 (15 to 20 tons) | 180240 | 14 inch |
| DSC/DSG and DFC/DFG 180-300 (15 to 25 tons) | 180300 | 14, 18 and 24 inch |
The important line is the 15 ton row. A 15 ton DCC and a 15 ton DSG do not share a curb. If a set of drawings only says "15 ton RTU," get the model number before ordering. For Rheem, the cabinet letter on the accessory table (C, D or G) is the key; the RXKG-DCC14 here is for the C cabinet. Carrier and American Standard curbs are matched to the unit series named on each product.
Step 2: Choose Downflow or Horizontal
Downflow curbs carry supply and return air straight down through the roof deck inside the curb, which is the usual arrangement for single-story commercial buildings with ductwork in the ceiling plenum. Horizontal curbs support a unit whose supply and return connect from the side, which is used when ducts run across the roof or into an adjacent wall, or where the structure below does not allow large roof openings.
The Daikin horizontal curbs are further split by which side of the unit the duct leaves from: the end, the service side or the non-service side. Pick the one that keeps the ductwork clear of the access panels and gives a clean route to the building penetration. Roofed-in versions are designed to be flashed into the roof membrane like a downflow curb; slab-mount versions are for setting on a pad or slab. Check the product drawings to confirm which applies to your site.
Step 3: Pick the Height
Curb height is a site decision, not a unit decision, and it should be agreed with the roofer and the designer before ordering. The factors that usually drive it:
- Roof assembly thickness. Tapered insulation and recovery boards eat into the curb. Flashing needs enough height above the finished roof surface to terminate properly, so a thick roof assembly often pushes you from 14 inches to 18 or 24.
- Snow and ponding. In snow country, or on flat roofs that hold water, a taller curb keeps the unit base and outdoor air intake above what accumulates.
- Condensate trap depth. Draw-through units need a trap deep enough for the coil static, and the trap has to fit under the drain connection above the roof. A taller curb leaves room.
- Service access and roof code requirements. Local building and mechanical codes, and the roofing manufacturer's warranty terms, can set minimum heights and clearances. Follow the project documents.
- Matching an existing condition. On a partial replacement, matching the height of neighboring curbs keeps duct transitions and the roof line consistent.
Step 4: Install in the Right Order
- Confirm the roof opening, structural framing and curb drawing agree. The structure must be designed to carry the unit's operating weight; that is the engineer's call, not the curb's.
- Assemble the knockdown curb on the roof. Knockdown curbs ship flat to save freight and are bolted or screwed together on site.
- Square the curb by measuring the diagonals, and level it. A curb out of level will make the unit drain poorly and can rack the cabinet.
- Fasten it to the structure as the project details require. Where wind or seismic restraint is specified, follow that detail.
- Install duct connections and any square-to-round adapters while the curb is open.
- Have the roofer insulate and flash the curb into the roof system.
- Apply the gasket the manufacturer specifies to the top rail, then set the unit and secure it as the unit instructions direct.
Ordering Tips
- Order the curb as soon as the unit model is final. It is needed on the roof before the unit, and the roofer's schedule often controls the date.
- For each unit, send the model number, downflow or horizontal, the discharge side if horizontal, and the height.
- Large-cabinet and horizontal curbs can take longer to source than standard 14-inch downflow curbs. Ask for current availability before setting the roofing date.
- If you are switching brands on a replacement, ask us to compare the old curb's dimensions against the new unit's curb drawing before you decide on a new curb versus an adapter.
Once the curb is settled, the rest of the unit's package is under Rooftop Unit Economizers, Fresh Air Dampers, Rooftop Unit Power Exhaust and Filter Racks and Duct Adapters.
Frequently Asked Questions
Can I set a 7.5 ton unit on a 3 to 6 ton curb?
No. The 7.5 to 12.5 ton units use a larger cabinet with different duct openings. Use the curb listed for the new unit's cabinet, or an engineered adapter.
Who flashes the curb, the mechanical contractor or the roofer?
Normally the roofer, so the roof warranty stays intact. The mechanical contractor sets, squares and fastens the curb and makes the duct connections. Confirm the split in the project scope.
What does "knockdown" mean on a Daikin curb?
The curb ships as flat panels and is assembled on site. It is cheaper to ship and easier to lift to the roof, but it has to be squared and leveled carefully during assembly.
Which Daikin curb fits a 15 ton unit?
It depends on the family. DCC/DCG 180-240 units use the 180240 curbs; DSC/DSG and DFC/DFG 180-300 units use the 180300 curbs. Check the model prefix.
Is a horizontal curb roofed-in or slab mount?
The Daikin 15 to 25 ton horizontal curbs are offered in both. Roofed-in is flashed into the roof; slab mount is for setting on a pad. Choose based on where the unit will sit.
Should I go taller than 14 inches?
Often yes on reroofed buildings with thick insulation, in snow regions, or where the condensate trap needs depth. Decide with the roofer before ordering.