Description
Product Summary
The Honeywell Residential Q3400A1024 is a gas valve from Honeywell Residential, described by the manufacturer as: 3 wire replaceable Ignitor/Flame rod assembly with 30" leads for honeywell SV smart valves. It is used with hot surface ignition systems and sized for 30" connections. It replaces Q3400A1040 & All Other Q3400A's.
A gas valve controls the flow of gas to the burner and, on pilot models, to the pilot. It opens only when the ignition system or thermocouple tells it the appliance is ready, regulates the outlet pressure to the burner and closes the moment the call for heat ends or a safety fails. Common signs of a failed gas valve are an igniter or spark that never lights the burner even though the valve receives voltage, a pilot that will not stay lit, manifold pressure that cannot be set, or a burner that keeps firing after the thermostat is satisfied.
Before you order, match Q3400A1024 to the part number on the part you are replacing or in your equipment's repair parts list, and confirm the voltage, size and connections match your equipment. If you are not sure which part your equipment needs, call us at 1.888.509.3391 with the model and serial number and we will confirm it for you.
Key Features
- Genuine Honeywell Residential part: Manufacturer part number Q3400A1024, factory new.
- Ignition Type: Hot Surface.
- Pipe Size: 30".
- Cross-reference: Replaces Q3400A1040 & All Other Q3400A's.
Frequently Asked Questions
Is this a genuine Honeywell Residential part?
Yes. This is the Honeywell Residential Q3400A1024, a factory-new gas valve from Honeywell Residential.
How do I make sure it fits my equipment?
Compare Q3400A1024 with the part number printed on the part you are replacing or listed in your equipment's repair parts list, and confirm the voltage and connections match. If you are not sure, call us at 1.888.509.3391 with your model and serial number and we will confirm it.
What part numbers does the Q3400A1024 replace?
The Honeywell Residential Q3400A1024 replaces Q3400A1040 & All Other Q3400A's.
Can I convert this gas valve between natural gas and LP?
Only if the valve is listed as convertible and the correct conversion kit and burner orifices are used. Gas conversions must be done by a qualified technician following the appliance manufacturer's instructions.
Should a professional install this part?
Yes. Gas, electrical, hydronic and combustion components should be installed by a qualified technician who can test the system afterward and follow the codes that apply where you live.