$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
Daikin
Daikin OEM Printed Circuit Board for FTKF/FTXC & More Ductless Indoor Units | 2558445
SKU: 2558445
$605.08- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
Daikin
Daikin OEM Printed Circuit Board for FTKF/FTXC & More Ductless Indoor Units | 2558446
SKU: 2558446
$605.08- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock -
$605.08
- 🚚Qualifies for FREE Shipping
- ⚡Fast Shipping
Ships from Mfg 7-10 Business Days3 in stock
Control Boards
Control boards are the decision makers inside heating, cooling and refrigeration equipment. A board reads the thermostat call, the safety switches and the sensors, then decides when the compressor starts, when the blower ramps up, when the igniter lights and when a defrost cycle begins. When a board fails, the equipment usually stops cold or behaves in ways that make no sense, even though every motor, valve and switch around it is still good. This category brings together OEM replacement control boards for residential and light commercial HVAC equipment along with electronic controllers, I/O modules and accessories for commercial refrigeration systems.
You will find printed circuit boards for Goodman, Daikin and Amana furnaces, air handlers, condensers, heat pumps and package units, ductless indoor and outdoor unit boards, wire harnesses that connect those boards, refrigerant mitigation boards for A2L systems, and Danfoss ADAP-KOOL case controllers, extension modules and communication modules used in supermarkets, walk-in coolers and cold rooms. Each listing names the exact part number it replaces, so matching the new board to the equipment on the job is a part number lookup rather than guesswork.
How Control Boards Work
Every control board does the same basic job: it takes low voltage inputs, applies the logic the manufacturer programmed into it, and switches outputs that run the equipment. What changes from one board to the next is what it watches and what it drives.
Furnace and air handler boards
An integrated furnace control runs the ignition sequence. On a call for heat it starts the draft inducer, waits for the pressure switch to prove airflow, energizes the hot surface igniter, opens the gas valve and then watches the flame sensor to confirm the burners lit. It also times the blower so warm air is delivered without blowing cold air at the start of the cycle. Air handler boards control the indoor blower speed, electric heat strip staging and, on variable speed models, communicate with the motor to deliver the right airflow for each stage of heating or cooling.
Condenser, heat pump and defrost boards
Outdoor unit boards manage the compressor contactor, the condenser fan, short cycle protection and, on heat pumps, the defrost cycle. A defrost board reads a coil temperature sensor and a timer, then switches the reversing valve and shuts down the outdoor fan long enough to melt frost off the coil. Inverter and variable capacity outdoor units use more advanced boards that drive the compressor through a variable frequency drive section and talk to the indoor unit over a communication wire.
Ductless indoor and outdoor unit boards
Ductless mini splits split their electronics between the indoor head and the outdoor unit. The indoor board receives commands from the remote, runs the fan motor and louvers, and reads room and coil sensors. The outdoor board controls the inverter compressor, the electronic expansion valve and the outdoor fan. Because the two boards communicate constantly, a fault on one side often shows up as an error code on the other, so reading the code correctly matters before ordering parts.
Refrigeration controllers and I/O modules
Commercial refrigeration uses dedicated electronic controllers instead of simple thermostats. A case or room controller such as the Danfoss AK-CC 750 manages temperature, defrost, evaporator fans, lights, anti-sweat heaters and door alarms for one or several display cases, and it can drive an electronic expansion valve to hold superheat tight. EKC controllers handle single cold rooms and cases. Rack and system controllers rely on extension modules that add analog inputs, digital inputs and relay or stepper outputs, while communication modules connect everything to a store system manager over LON, Modbus or other networks so alarms and settings can be monitored from one place.
Mitigation and safety boards
Newer equipment built for A2L refrigerants such as R-454B and R-32 includes a refrigerant detection and mitigation board. If the leak sensor detects refrigerant, the board turns on the indoor blower to dilute it and locks out ignition sources. These boards are required safety components on A2L systems and must be replaced with the correct part rather than bypassed.
Signs a Control Board Is Failing
Boards rarely fail without a reason, and the reason is often outside the board itself. Before replacing one, rule out the usual causes, because a new board installed on a system with the same underlying problem will fail again.
- No operation at all. The equipment does nothing on a call. Check for 24 volt power at the board and look for a blown low voltage fuse first. A shorted thermostat wire or a failed component downstream is the most common reason a fuse opens.
- Flashing fault codes. Most boards blink an LED or show a code that points to the problem. The code usually names a sensor, switch or motor fault, not the board itself, so look it up in the unit's service literature before condemning the board.
- Burnt traces or relays. Visible scorching, a swollen capacitor on the board or a relay that clicks but never closes its contacts are clear signs of board damage, often caused by a shorted motor or contactor coil.
- Intermittent or erratic behavior. A blower that runs when it should not, a compressor that short cycles, or a defrost cycle that never ends can come from a failing board, but loose connections and bad sensors cause the same symptoms.
- Communication errors. On ductless and communicating systems, a lost communication code can point to a board, a damaged communication wire or incorrect wiring between the indoor and outdoor units.
- Refrigeration alarms. On commercial systems, sensor errors, temperature alarms or a controller that drops off the network can be traced to a failed sensor, a wiring problem or a controller or module that needs replacement.
How to Choose the Right Replacement
The safest way to choose a control board is by the exact OEM part number printed on the old board or listed in the equipment's parts manual. Many boards look alike but run different firmware or have different settings for specific models, and installing the wrong one can cause anything from nuisance lockouts to equipment damage.
Residential HVAC boards
Start with the model and serial number of the unit, then confirm the part number in the manufacturer's parts list. Watch for superseded part numbers, where the manufacturer has replaced an older board with a newer version that fits the same equipment. Some replacement boards need dip switch or jumper settings matched to the old board, such as blower off delay, heat pump versus air conditioner mode or furnace input, so note the old settings before removing it.
Ductless boards
Ductless boards are specific to the indoor or outdoor model and often to the capacity. Match the full model number of the unit, not just the series, and confirm whether the board is for the indoor head or the outdoor unit. If the board ships with a separate wire harness, order the harness listed for that model as well.
Refrigeration controllers and modules
For Danfoss systems, match the code number on the controller or module label, such as 080Z0130 for the AK-CC 750 multicase controller or 080Z0010 for an AK2-XM 205A extension module. Confirm the supply voltage, the number and type of inputs and outputs, and the communication protocol your system manager uses. When expanding a system, make sure the new module is compatible with the controller it will plug into and that you have the correct DIN rail, brackets and cables.
Installation and Safety Tips
- Shut off all power to the equipment at the disconnect before removing a board, and verify it is off with a meter. Many units have more than one power source.
- Photograph the old board and label every wire before disconnecting anything. A single wire on the wrong terminal can damage a new board the moment power is restored.
- Handle boards by the edges and discharge static before touching them. Electronic components can be damaged by static you cannot feel.
- Transfer any dip switch, jumper or configuration settings from the old board, and program refrigeration controllers with the correct parameters for the case or room before returning it to service.
- Find and fix the root cause of the failure, such as a shorted motor, a failed contactor coil or a chafed thermostat wire, before powering up the new board.
- After installation, run the equipment through a full cycle and confirm the fault code is cleared, the safeties respond correctly and, on refrigeration systems, that temperatures, defrost and alarms behave as expected.
- Control board replacement involves line voltage, gas controls and refrigerant safety devices. It should be done by a qualified HVAC or refrigeration technician who follows local codes.
Part Details
Each product page lists the part number, the equipment it is intended for, key specifications and the shipping time. OEM boards are genuine manufacturer parts. Danfoss refrigeration controls are sold under their Danfoss code numbers so they can be matched directly to existing system documentation. Stock levels are shown on each listing, and many parts ship within a few business days.
Frequently Asked Questions
How do I know if the board or another part is the problem?
Read the fault code first and test the component it points to. Confirm the board has 24 volt power, check the fuse, and verify that the board is sending power to an output when it should. If the board receives the correct inputs but never energizes the right output, the board is the likely cause.
Can I use a universal board instead of the OEM part?
Universal boards exist for some furnaces and defrost applications, but they may not support every feature of the original, such as variable speed blower control or communicating thermostats. For ductless, inverter and communicating equipment, the OEM board is the reliable choice.
What does a superseded part number mean?
It means the manufacturer has replaced the original board with a newer version. The new board is designed to fit the same equipment, though it may look different or need settings transferred from the old one.
Do Danfoss extension modules work with any controller?
No. AK2 and AK-XM modules are designed to work with specific Danfoss controllers and plug into their local bus. Check the controller model and the module type before ordering, and make sure the module provides the inputs and outputs your application needs.
Why did my new board fail right away?
The most common reason is that the original cause of the failure was never fixed. A shorted component, a miswired terminal or a power surge can take out a replacement board just as it did the original, so diagnose the system before and after the swap.