null

HVAC365 1/4" x 3/8" 15 Foot Copper Line set | Ductless Mini Split Units | Pre-flared & Insulated

HVAC365

Local HVAC Offers

Special pricing available — add to cart or call for details.
Limited-time availability.
About this promotion
Cyber Weekend Sales Event

No reviews yet Write a Review
SKU:
1438-15-HVAC365
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
25.00 (in)
Height:
6.00 (in)
Depth:
25.00 (in)

Questions about HVAC365 1/4" x 3/8" 15 Foot Copper Line set | Ductless Mini Split Units | Pre-flared & Insulated?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

At a glance

Fast Shipping

Customer Support

Warranty Coverage

Financing Avaliable

$150.95

95 in stock • Ships in 1-2 Business Days

Description

The HVAC365 1/4-inch x 3/8-inch copper line set is a 15-foot refrigerant piping assembly designed for compatible ductless mini-split systems. It provides the paired copper tubes used to connect an indoor air handler to its matching outdoor condenser, creating the refrigerant path between the two components. This line set is intended for HVAC contractors, installers, and property owners whose equipment documentation specifically requires 1/4-inch and 3/8-inch refrigerant connections.

The 15-foot length is suited to installations where the indoor and outdoor equipment can be placed relatively close together. When measuring the required distance, buyers should consider the complete planned route rather than the straight-line distance between components. Bends, wall penetrations, vertical sections, equipment clearances, and service allowances can increase the amount of tubing required.

This line set is supplied in a pre-flared configuration, which can reduce the tube-end preparation needed when the provided flares match the equipment connections. Included insulation helps protect the refrigerant tubing and limit unwanted heat transfer during system operation. Professional inspection and installation are still required before the HVAC system can be operated.

Key Features

  • 1/4-inch and 3/8-inch tubing sizes: Includes the two specified copper tube diameters for compatible ductless mini-split equipment
  • 15-foot line-set length: Intended for relatively short routes between an indoor unit and outdoor condenser
  • Pre-flared configuration: Helps reduce on-site tube preparation when the factory flares fit the equipment connections
  • Insulated copper tubing: Supplied with insulation to support refrigerant piping installation
  • Ductless mini-split application: Designed for use between compatible indoor and outdoor mini-split components
  • HVAC365 SKU 1438-15-HVAC365: Identifies this specific 1/4-inch x 3/8-inch, 15-foot configuration

The coiled line set has a listed product weight of approximately 10 pounds. It should be handled and uncoiled carefully to prevent kinks, flattened tubing, damaged flare ends, or torn insulation. The tubing should not be bent more tightly than permitted by accepted installation practices and the connected equipment’s documentation.

The product’s connection sizes, length, pre-flared construction, insulation, SKU, and listed weight are confirmed on the HVAC365 product page.

Compatibility and Installation Notes

This line set is not compatible with every ductless mini-split system. Confirm that both the indoor unit and outdoor condenser specify 1/4-inch and 3/8-inch refrigerant connections. Do not select a line set based only on the system’s brand or BTU capacity because connection sizes can vary between models.

The 15-foot length must also meet the equipment manufacturer’s minimum and maximum piping requirements. Some systems require a minimum line length, while others have limits for total piping distance and vertical separation. The condenser documentation should also be reviewed to determine whether the factory refrigerant charge covers a 15-foot installation.

Pre-flared tubing must still be inspected before connection. Each flare should be clean, correctly formed, undamaged, and properly aligned with the equipment fitting. Flare nuts must be tightened to the torque specified by the HVAC manufacturer. The finished refrigerant circuit must then be evacuated, leak tested, and commissioned using approved procedures.

The product listing does not identify communication wire, electrical cable, condensate tubing, wall sleeves, line-set covers, adapters, or mounting hardware as included. Buyers should verify all additional installation components before starting the project.

Frequently Asked Questions

What tubing sizes are included?
The line set includes 1/4-inch and 3/8-inch copper tubing.

How long is the line set?
The listed tubing length is 15 feet.

Will this line set fit every mini split?
No. The equipment must specifically require 1/4-inch and 3/8-inch refrigerant connections.

Does pre-flared mean no installation work is required?
No. The flares must be inspected, connected, properly torqued, evacuated, and leak tested.

Can the tubing be shortened?
A qualified HVAC technician may shorten it when permitted, but the cut tubing will require proper preparation and a new flare.

Confirm the required connection sizes and piping length for your equipment before purchasing this HVAC365 line set.

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
HVAC365
Width:
25.00 (in)
Height:
6.00 (in)
Depth:
25.00 (in)
Weight:
10.00 LBS
Safety Information:
PROP 65 WARNING: This product and other products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm.

Warranty Information

30 Day Parts

Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document


Fast Shipping

Easy Returns

Warranty Coverage

Financing Available