Description
Rheem 32 Amp 1 Pole Contactor
The Rheem 42-109499-06K is a 1-pole definite purpose contactor rated 32 full load amps (contactor reference XMC0-321). A contactor is the switch inside the outdoor unit that the thermostat closes through the low-voltage control circuit to start the compressor and condenser fan motor. It is an A2L-rated contactor, built for the newer A2L refrigerant equipment such as R-454B and R-32 systems, where the components are rated for use with mildly flammable refrigerants. It is an OEM replacement part number used across Rheem and Ruud equipment.
Choosing a replacement
Match the number of poles, the coil voltage and the full load amp rating to the original contactor or the unit wiring diagram, and never go below the original amp rating. On A2L refrigerant equipment, replace an A2L-rated contactor only with another A2L-rated part. Pitted, burned or welded contacts and a buzzing coil are the usual signs a contactor is done. Turn the power off at the disconnect, label the wires before removing the old part, and confirm the coil is getting its control voltage once the new one is in.