Description
Product Summary
The Supco LTT Logit Dual Temperature is a professional-grade replacement part from Supco (Sealed Unit Parts Co.), a trusted name in HVAC/R and appliance parts since 1945. LOGiT Series data loggers are designed with the latest technology. Economic, compact and easy to use. Select the proper logger for your application, along with the LOGiT software interface package (LLSU).
Data loggers and probes record temperature, humidity, pressure, or electrical readings over time so you can prove compliance, document system performance, and diagnose intermittent problems that never show up while you're on site.
Key Features
- 30 character user ID field
- Compatible with Windows® 2000, XP, Vista and Windows® 7/8/ & 10. 32 and 64 bit systems
- Data exportable to text or Excel® files
- Memory rollover, or stop on memory full
- Over / Under Alarm settings with visual indicator
- Password protected, user selectable single point offset calibration available through software
- Real time data monitoring
- Recording Start, on button, immediate after setup, or user specified date & time
- Sample rate 1 second to 18 hours
- Stores over 10,000 measurement points
- System requirements: 5MB free disk space, 800 x 600 screen resolution, 1 free USB port
- Tamper proof
- Two independent, 6 foot external stainless steel tip sensors
Specifications
| Brand | Supco |
|---|---|
| Part Number | LTT |
| Part Type | Data Logger |
| Operating Temperature | -50°F to 300°F (-46°C to 150°C) |
| Storage Temperature | -40°F to 150°F (-40°C to 65°C) |
| Temperature Accuracy | ± 2°F (± 1°C) |
Frequently Asked Questions
My PC does not have a disc drive, how can I install the software?
See the White Paper section on this page.
Do the loggers have a recommended calibration interval?
We do not have a recommended calibration interval. Calibration can be performed through the software at any time.
Can (1) LLSU be used with multiple loggers?
Yes.
Is there a manual for the Loggers?
The manual is built into the software. Open software, Click 'Help' on the Toolbar, then click 'Help Topics'. This is the manual.
How do I clear the logger data?
Logger data will be cleared upon starting a new logging session.
Related Parts
Commonly used with: Supco LLSU, Supco DLTP6.
White Paper
What's Included
- (1) Supco LTT Logit Dual Temperature
Safety: Always disconnect power and follow lockout/tagout procedures before servicing electrical components. Installation should be performed by a qualified technician.