Description
Product Summary
The Supco SPP7S Super Seven Hard Start Kit is a professional-grade replacement part from Supco (Sealed Unit Parts Co.), a trusted name in HVAC/R and appliance parts since 1945. Hard Start Kit Positive Temperature Coefficient (PTC) Relay and Start Capacitor SPP Series.
Hard start kits give a struggling compressor the extra starting torque it needs on low-voltage days, after long off-cycles, or when an aging compressor begins to trip on locked-rotor amps. Adding the correct hard start reduces start-up current spikes, cuts down on nuisance breaker trips, and can extend compressor life on PSC-type single-phase systems. Always match the kit to the compressor horsepower and system voltage.
Key Features
- Can be used on PSC type compressors
- Easy 2-wire installation
- Most economic
- NATE® Recognized (Course #1867-0002)
- PTC Positive Temperature Coefficient Relay and Capacitor
- UL® Recognized
Specifications
| Brand | Supco |
|---|---|
| Part Number | SPP7S |
| Part Type | Hard Start Kit |
| Operating Voltage VAC | 90 to 277 VAC |
| Recommended Range (hp) | 1/2 - 10 hp |
| Capacitor size (µF) | 130 to 156 MFD |
| Torque Increase | 600% Increase |
Cross Reference
The Supco SPP7S is a direct replacement for the following OEM and competitor part numbers. Always verify ratings and fit against the original part before installing.
| Replaces Part # | Manufacturer | Description |
|---|---|---|
| 32702 | MARS® | Hard Start |
Ideal Applications
- Residential and light commercial air conditioners and heat pumps
- Hard-starting or locked-rotor compressors
- Low-voltage sites and long line runs
Frequently Asked Questions
Can the hard start be mounted sideways?
No, hard starts should always be upright.
Are the wire leads polarity sensitive?
No
Where do I attach the (2) wires? (Always disconnect power before installation)?
Attach (1) wire to Common, and the other to the Hermetic terminal on the Run Cap.
White Paper
- Supco SPP7S Product Specification Sheet (PDF)
- Supco SPP7S Product Specification Sheet 2 (PDF)
- Supco SPP7S Application Sheet (PDF)
What's Included
- (1) Supco SPP7S Super Seven Hard Start Kit
Safety: Always disconnect power and follow lockout/tagout procedures before servicing electrical components. Installation should be performed by a qualified technician.