Trenton 0.7 HP Walk-In Cooler Refrigeration System for 6' x 6' or 6' x 8' Box, R-448A, 208/230V 1-Phase | TEZA007H8HS2DB TLP106MAS1D

Trenton

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
TEZA007H8HS2DB-TLP106MAS1D
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
30.25 (in)
Height:
35.88 (in)
Depth:
31.00 (in)

Questions about Trenton 0.7 HP Walk-In Cooler Refrigeration System for 6' x 6' or 6' x 8' Box, R-448A, 208/230V 1-Phase | TEZA007H8HS2DB TLP106MAS1D?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$6,988.96

  • Qualifies for FREE Shipping
1 in stock • Ships in 1-2 Business Days
Overview

Trenton 0.7 HP Walk-In Cooler Refrigeration System for 6' x 6' or 6' x 8' Box, R-448A, 208/230V 1-Phase | TEZA007H8HS2DB TLP106MAS1D

Trenton walk-in cooler refrigeration system for a 6' x 6' or 6' x 8' box: TEZA007H8HS2DB condensing unit and TLP106MAS1D unit cooler
Product details

Description

Product Summary

This Trenton walk-in cooler refrigeration system pairs the TEZ TEZA007H8HS2DB 0.7 HP medium temperature scroll condensing unit with the TLP TLP106MAS1D low profile unit cooler. It is sized for a 6' x 6' or 6' x 8' walk-in cooler with an 8 ft ceiling held at 35°F.

How we matched it: we used Trenton's published box loads and capacity ratings. A 6' x 6' or 6' x 8' cooler has a standard load of 4,986 BTU/h (6' x 6') and 5,884 BTU/h (6' x 8'). The TEZA007H8HS2DB delivers 7,410 BTU/h at a 25°F suction temperature with 95°F outdoor air on R-448A, and the TLP106MAS1D is rated 6,000 BTU/h at a 10°F temperature difference, so both pieces cover the load. This is the same condensing unit Trenton pairs with its own pre-assembled coil for this box size.

The TEZ condensing unit is Trenton's Generation D EZ-Line, built around a Copeland ZB06KAE scroll compressor in an outdoor cabinet on 208/230V single-phase power. It comes with a receiver, a sealed liquid line filter drier and a sight glass and it is AWEF compliant on R-448A and R-449A.

The TLP unit cooler is a low profile coil with EC SmartSpeed fan motors on 115V 1-Phase and air defrost. It ships without an expansion valve, solenoid valve or thermostat, so add them below or supply your own.

Key Features

  • Sized for 6' x 6' or 6' x 8': both units cover the standard cooler load at 95°F outdoor air on R-448A.
  • Copeland scroll compressor: the ZB06KAE scroll in the TEZ unit runs quietly and efficiently, with a receiver, drier and sight glass built in.
  • Low profile EC fan coil: the TLP106MAS1D uses EC SmartSpeed motors to save power inside the box.
  • Add what you need: pick the expansion valve kit, liquid line solenoid valve and room thermostat right on this page.

Frequently Asked Questions

What size walk-in cooler is this system for?

It is sized for a 6' x 6' or 6' x 8' walk-in cooler with an 8 ft ceiling held at 35°F under a standard load. A box with heavy door traffic, warm product loading or glass doors can need more capacity, so call us at 1.888.509.3391 before ordering if your box is different.

Is this a Trenton factory system?

Trenton does not publish this exact pairing. We matched it from Trenton's own box loads and capacity ratings, using the same condensing unit Trenton selects for this box size. Walk-in refrigeration does not use AHRI matched-system numbers; each unit is rated on its own for AWEF.

What else do I need to install it?

The unit cooler needs a thermostatic expansion valve, a liquid line solenoid valve and a room thermostat. You can add all three from the options on this page. You will also need refrigerant piping, insulation and wiring sized for the job.

Does this system need a licensed installer?

Yes. A split refrigeration system needs refrigerant piping, evacuation, charging and electrical work, so it should be installed by a licensed refrigeration technician following Trenton's installation instructions.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Trenton
Width:
30.25 (in)
Height:
35.88 (in)
Depth:
31.00 (in)
Weight:
229.50 LBS
Product Category:
Walk-In Cooler Refrigeration System
System Type:
Split Condensing Unit + Unit Cooler
Box Size:
6' x 6' x 8' or 6' x 8' x 8' (W x L x H)
Application:
Walk-In Cooler (Medium Temp)
Room Temperature:
35°F
Estimated Box Load:
4,986 BTU/h (6' x 6') / 5,884 BTU/h (6' x 8') (standard load)
Matched By:
HVAC365 engineered match (Trenton box loads and published capacities)
Selection Conditions:
95°F ambient, R-448A, 25°F SST, 10°F TD
Refrigerant (as selected):
R-448A
Refrigerant Type:
R-448A / R-449A
Condensing Unit Capacity at Selection:
7,410 BTU/h
Unit Cooler Capacity at Selection:
6,000 BTU/h (nominal, 10°F TD)
Defrost Type:
Air Defrost
Voltage / Phase:
208/230V 1-Phase
Unit Cooler Voltage:
115V 1-Phase
Brand:
Trenton
Model Number:
TEZA007H8HS2DB TLP106MAS1D
Outdoor Unit TEZA007H8HS2DB - Voltage / Phase:
208/230V 1-Phase
Outdoor Unit TEZA007H8HS2DB - Electrical Frequency:
60 Hz
Outdoor Unit TEZA007H8HS2DB - Model Number:
TEZA007H8HS2DB
Outdoor Unit TEZA007H8HS2DB - Product Category:
Refrigeration Condensing Unit
Outdoor Unit TEZA007H8HS2DB - Product Line:
Trenton TEZ Generation D Scroll Condensing Units
Outdoor Unit TEZA007H8HS2DB - Horsepower (HP):
0.7
Outdoor Unit TEZA007H8HS2DB - Temperature Application:
Medium/High Temp
Outdoor Unit TEZA007H8HS2DB - Compressor Type:
Copeland Scroll
Outdoor Unit TEZA007H8HS2DB - Compressor Model:
ZB06KAE
Outdoor Unit TEZA007H8HS2DB - Refrigerant Type:
R-407A, R-407C, R-404A, R-507, R-448A
Outdoor Unit TEZA007H8HS2DB - Minimum Circuit Ampacity (MCA):
8.5
Outdoor Unit TEZA007H8HS2DB - Maximum Overcurrent Protection (MOP):
15
Outdoor Unit TEZA007H8HS2DB - Liquid Line Size:
3/8 in
Outdoor Unit TEZA007H8HS2DB - Suction Line Size:
5/8 in
Outdoor Unit TEZA007H8HS2DB - Connection Type:
ODS (sweat)
Outdoor Unit TEZA007H8HS2DB - Receiver Included:
Yes
Outdoor Unit TEZA007H8HS2DB - Receiver Capacity (90% Full):
5.4 lb
Outdoor Unit TEZA007H8HS2DB - Compressor Oil:
Polyol Ester
Outdoor Unit TEZA007H8HS2DB - Factory Features:
Sealed liquid line filter drier and sight glass
Outdoor Unit TEZA007H8HS2DB - Defrost Type:
Air Defrost / Off-Cycle
Outdoor Unit TEZA007H8HS2DB - AWEF Compliance:
AWEF for R-448A, R-449A, R-404A, R-507
Outdoor Unit TEZA007H8HS2DB - Indoor/Outdoor:
Outdoor
Outdoor Unit TEZA007H8HS2DB - Chassis Size:
1
Outdoor Unit TEZA007H8HS2DB - Unit Weight:
183 lb
Indoor Unit TLP106MAS1D - Voltage / Phase:
115V 1-Phase
Indoor Unit TLP106MAS1D - Electrical Frequency:
60 Hz
Indoor Unit TLP106MAS1D - Model Number:
TLP106MAS1D
Indoor Unit TLP106MAS1D - Product Category:
Walk-In Unit Cooler (Evaporator)
Indoor Unit TLP106MAS1D - Product Line:
Trenton TLP Low Profile Evaporators
Indoor Unit TLP106MAS1D - Capacity (BTU/h):
6,000
Indoor Unit TLP106MAS1D - Nominal Capacity (model designation):
6,000 BTU/h
Indoor Unit TLP106MAS1D - Temperature Application:
Medium Temp
Indoor Unit TLP106MAS1D - Defrost Type:
Air Defrost
Indoor Unit TLP106MAS1D - Fins Per Inch:
6
Indoor Unit TLP106MAS1D - Number of Fans:
1
Indoor Unit TLP106MAS1D - Airflow (CFM):
705
Indoor Unit TLP106MAS1D - Fan Motor:
EC Motor - SmartSpeed
Indoor Unit TLP106MAS1D - Motor FLA:
0.6
Indoor Unit TLP106MAS1D - Unit MCA:
0.8
Indoor Unit TLP106MAS1D - Refrigerant Type:
R-407A, R-407C, R-448A, R-449A, R-404A, R-507
Indoor Unit TLP106MAS1D - A2L Ready:
No
Indoor Unit TLP106MAS1D - Liquid Line Size:
1/2 in
Indoor Unit TLP106MAS1D - Coil Inlet Size:
1/2 in
Indoor Unit TLP106MAS1D - Suction Line Size:
5/8 in
Indoor Unit TLP106MAS1D - Indoor/Outdoor:
Indoor (walk-in box)
Indoor Unit TLP106MAS1D - Unit Weight:
46.5 lb
Indoor Unit TLP106MAS1D - Unit Dimensions (W x D x H):
30.25 in x 13.44 in x 15.88 in
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Frequently asked questions
What refrigerant does the use?
It uses R-448A / R-449A refrigerant.
What power supply does the need?
It requires 208/230V 1-Phase power.
Who makes the TEZA007H8HS2DB-TLP106MAS1D?
The TEZA007H8HS2DB-TLP106MAS1D is made by Trenton.