Description
Product Summary
The White-Rodgers 25M01A-101 is a gas valve from White-Rodgers, described by the manufacturer as: 120V 3/8" X 11/32" direct lite dual solenoid gas valve with regulator & terminal connector universal right angle right application includes LP kit. It is rated for 120V, set up for natural gas with LP conversion and sized for 3/8" x 11/32" connections. It replaces 8281920.
A gas valve controls the flow of gas to the burner and, on pilot models, to the pilot. It opens only when the ignition system or thermocouple tells it the appliance is ready, regulates the outlet pressure to the burner and closes the moment the call for heat ends or a safety fails. Common signs of a failed gas valve are an igniter or spark that never lights the burner even though the valve receives voltage, a pilot that will not stay lit, manifold pressure that cannot be set, or a burner that keeps firing after the thermostat is satisfied.
Before you order, match 25M01A-101 to the part number on the part you are replacing or in your equipment's repair parts list, and confirm the voltage, size and connections match your equipment. If you are not sure which part your equipment needs, call us at 1.888.509.3391 with the model and serial number and we will confirm it for you.
Key Features
- Genuine White-Rodgers part: Manufacturer part number 25M01A-101, factory new.
- Voltage: 120V.
- Gas Type: Natural Gas & LP.
- Cross-reference: Replaces 8281920.
Frequently Asked Questions
Is this a genuine White-Rodgers part?
Yes. This is the White-Rodgers 25M01A-101, a factory-new gas valve from White-Rodgers.
How do I make sure it fits my equipment?
Compare 25M01A-101 with the part number printed on the part you are replacing or listed in your equipment's repair parts list, and confirm the voltage and connections match. If you are not sure, call us at 1.888.509.3391 with your model and serial number and we will confirm it.
What part numbers does the 25M01A-101 replace?
The White-Rodgers 25M01A-101 replaces 8281920.
Can I convert this gas valve between natural gas and LP?
Only if the valve is listed as convertible and the correct conversion kit and burner orifices are used. Gas conversions must be done by a qualified technician following the appliance manufacturer's instructions.
Should a professional install this part?
Yes. Gas, electrical, hydronic and combustion components should be installed by a qualified technician who can test the system afterward and follow the codes that apply where you live.