Cooper & Hunter Ceiling Cassette 36,000 BTU 3 Ton 20 SEER2 4-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V with Wi-Fi | CH-R36LCU-230VO-CH-RH36LCCT

Cooper & Hunter

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
CH-R36LCU-230VO-CH-RH36LCCT
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
37.20 (in)
Height:
31.90 (in)
Depth:
16.10 (in)

Questions about Cooper & Hunter Ceiling Cassette 36,000 BTU 3 Ton 20 SEER2 4-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V with Wi-Fi | CH-R36LCU-230VO-CH-RH36LCCT?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$7,613.33

  • Qualifies for FREE Shipping
10 in stock • Ships in 3-5 Business Days
Overview

Cooper & Hunter Ceiling Cassette 36,000 BTU 3 Ton 20 SEER2 4-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V with Wi-Fi | CH-R36LCU-230VO-CH-RH36LCCT

Complete system: Cooper & Hunter Ceiling Cassette 36,000 BTU 3 Ton 20 SEER2 4-Way Ceiling Cassette Ductless Mini Split Heat Pump System R-454B 208/230V with Wi-Fi - complete system with included remote
Product details

Description

The Cooper & Hunter Ceiling Cassette 36,000 BTU 4-way ceiling cassette system pairs the CH-R36LCU-230VO outdoor heat pump with the CH-RH36LCCT indoor unit as an AHRI-matched single-zone ductless mini split (AHRI #215864210). It is rated at 20 SEER2 on R-454B refrigerant and runs on 208/230V single-phase power, heating and cooling one room or zone without ductwork.

The 4-Way Ceiling Cassette recesses into a standard drop ceiling and spreads air in four directions. It has a humidity sensor (no refrigerant detection sensor on this version). The decorative panel is a separate part number and is included in this system.

What's Included

  • 1 × CH-R36LCU-230VO Cooper & Hunter outdoor heat pump condenser
  • 1 × CH-RH36LCCT Ceiling Cassette 4-way ceiling cassette indoor unit
  • 1 × CH-NPNL24-48CT decorative panel (grille)
  • 1 × wireless remote control
  • Smart Kit (Wi-Fi, Cooper & Hunter app)

System Performance

  • AHRI Reference Number: 215864210
  • Nominal Capacity: 36,000 BTU/h (3 ton)
  • SEER2: 20
  • HSPF2 (Region IV): 10.2
  • Heating Capacity @ 47°F: 40,000 (8,100~43,500)
  • Refrigerant: R-454B
  • Power Supply: 208/230V 1-Phase 60 Hz
  • Outdoor Unit Type: Regular (heats down to -13°F)

Component Specifications

Outdoor Unit — CH-R36LCU-230VO

  • Model: CH-R36LCU-230VO
  • Cooling Capacity, rated (min~max) BTU/h: 36,000 (7,900~42,500)
  • Heating Capacity, rated (min~max) BTU/h: 40,000 (8,100~43,500)
  • COP @ 47°F: 3.7
  • HSPF2 (Region IV / V): 10.2 / 7.8
  • Refrigerant Piping (Liquid/Gas): 3/8"/3/4"
  • Max Line Length (ft): 246
  • Max Height Difference (ft): 98.4
  • Minimum Circuit Ampacity (A): 33
  • Max Fuse / Breaker (A): 35
  • Outdoor Sound Level (dB(A)): 63
  • Cooling Operating Range (°F outdoor): -13~122
  • Heating Operating Range (°F outdoor): -13~75
  • Unit Dimensions (W x D x H): 37.24 in x 16.14 in x 31.89 in
  • Net / Shipping Weight: 152.34 lb / 162.48 lb

Indoor Unit — CH-RH36LCCT

  • Model: CH-RH36LCCT
  • Cooling Capacity (BTU/h): 36,000
  • Refrigerant Piping (Liquid/Gas): 3/8"/3/4"
  • Airflow (CFM, high to low): 1,041.8 / 947.6 / 853.5 / 753.4
  • Sound Level (dB(A), high/med/low): 52/47.5/40
  • Condensate Drain: 1"
  • Unit Dimensions (W x D x H): 32.68 in x 32.68 in x 9.65 in
  • Net / Shipping Weight: 59.30 lb / 71.43 lb

Installation Notes

Mini split heat pumps must be installed by a licensed HVAC technician: the line set is flared, pressure tested, evacuated and charge-adjusted on site. R-454B is a mildly flammable (A2L) refrigerant, so A2L-rated tools and the manufacturer's procedures are required. Size the unit from a room load calculation rather than square footage alone. Each outdoor unit needs its own dedicated circuit sized to the rating plate (33 A MCA, 35 A max fuse).

White Paper

Common Questions

Does this system come with a line set?

No. The line set, communication wire, wall sleeve, condensate line and mounting hardware are sold separately.

Can this outdoor unit run more than one indoor unit?

No. This is a single-zone (one outdoor to one indoor) system. Cooper & Hunter multi-zone condensers are listed separately.

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Cooper & Hunter
Width:
37.20 (in)
Height:
31.90 (in)
Depth:
16.10 (in)
Weight:
233.90 LBS
Prop 65 Warning:
Yes
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Category:
Ductless Mini Split Single Zone
Series:
Ceiling Cassette
System Type:
Heat Pump
Zones:
1
Configuration:
Ceiling Cassette
Mount Type:
Ceiling Cassette
Indoor Air Handler Type(s):
4-Way Ceiling Cassette
Capacity (Tons):
3
Cooling Capacity (BTU):
36,000
SEER2:
20+ SEER2
AHRI Certified:
Yes
AHRI Reference Number:
215864210
Refrigerant Type:
R-454B
Compressor Type:
Inverter
Connection Type:
Flare Fittings
Voltage / Phase:
208/230V 1-Phase
Electrical Phase:
1-Phase
Cold Climate:
No
Minimum Heating Temp (°F):
-13
Outdoor Unit Model:
CH-R36LCU-230VO
Indoor Unit Model:
CH-RH36LCCT
HSPF2:
10+ HSPF2
Breaker Size (Amps):
35
Outdoor Unit CH-R36LCU-230VO - Cooling Capacity, rated (min~max) BTU/h:
36,000 (7,900~42,500)
Outdoor Unit CH-R36LCU-230VO - Heating Capacity, rated (min~max) BTU/h:
40,000 (8,100~43,500)
Outdoor Unit CH-R36LCU-230VO - COP @ 47°F:
3.7
Outdoor Unit CH-R36LCU-230VO - HSPF2 (Region IV / V):
10.2 / 7.8
Outdoor Unit CH-R36LCU-230VO - Refrigerant Piping (Liquid/Gas):
3/8"/3/4"
Outdoor Unit CH-R36LCU-230VO - Max Line Length (ft):
246
Outdoor Unit CH-R36LCU-230VO - Max Height Difference (ft):
98.4
Outdoor Unit CH-R36LCU-230VO - Minimum Circuit Ampacity (A):
33
Outdoor Unit CH-R36LCU-230VO - Max Fuse / Breaker (A):
35
Outdoor Unit CH-R36LCU-230VO - Outdoor Sound Level (dB(A)):
63
Outdoor Unit CH-R36LCU-230VO - Cooling Operating Range (°F outdoor):
-13~122
Outdoor Unit CH-R36LCU-230VO - Heating Operating Range (°F outdoor):
-13~75
Outdoor Unit CH-R36LCU-230VO - Unit Dimensions (W x D x H):
37.24 in x 16.14 in x 31.89 in
Outdoor Unit CH-R36LCU-230VO - Net / Shipping Weight:
152.34 lb / 162.48 lb
Indoor Unit CH-RH36LCCT - Cooling Capacity (BTU/h):
36,000
Indoor Unit CH-RH36LCCT - Refrigerant Piping (Liquid/Gas):
3/8"/3/4"
Indoor Unit CH-RH36LCCT - Airflow (CFM, high to low):
1,041.8 / 947.6 / 853.5 / 753.4
Indoor Unit CH-RH36LCCT - Sound Level (dB(A), high/med/low):
52/47.5/40
Indoor Unit CH-RH36LCCT - Condensate Drain:
1"
Indoor Unit CH-RH36LCCT - Unit Dimensions (W x D x H):
32.68 in x 32.68 in x 9.65 in
Indoor Unit CH-RH36LCCT - Net / Shipping Weight:
59.30 lb / 71.43 lb
Decorative Panel Included:
CH-NPNL24-48CT
Heating Output (BTU):
40,000 - 69,000 BTU
EER2:
12 EER2
Sound Level Indoor (dB):
40
Sound Level Outdoor (dB):
63
Liquid Line Size | OD - Outside Diameter:
3
Suction Line Size | OD - Outside Diameter:
8"
Minimum Circuit Ampacity (MCA):
33
Maximum Overcurrent Protection (MOP):
35
Max Line Length (ft):
246
Shipping Weight:
233.9 lb
Wi-Fi Control:
Built-In
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
7 Years Compressor & 5 Years Parts | Registration Required within 60 Days of Installation
Frequently asked questions
How many zones does the support?
It supports 1 zone(s).
What size is the ?
The is a 3 ton unit.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What is the SEER2 rating of the ?
The is rated at 20+ SEER2 SEER2.
Is the AHRI certified?
Yes. The AHRI reference number is 215864210.
What refrigerant does the use?
It uses R-454B refrigerant.
What power supply does the need?
It requires 208/230V 1-Phase power.
How cold can it be outside for the to keep heating?
It is rated to heat down to -13 °F outdoors.
What is the HSPF2 heating efficiency of the ?
It is rated at 10+ HSPF2 HSPF2.
How loud is the outdoors?
The rated outdoor sound level is 63 dB.
Can the be controlled over Wi-Fi?
Built-In.
What warranty comes with the CH-R36LCU-230VO-CH-RH36LCCT?
7 Years Compressor & 5 Years Parts | Registration Required within 60 Days of Installation
Who makes the CH-R36LCU-230VO-CH-RH36LCCT?
The CH-R36LCU-230VO-CH-RH36LCCT is made by Cooper & Hunter.