Daikin 7.5 Ton 16.0 IEER / 11.4 EER R-32 Commercial Split Heat Pump Outdoor Unit, 460V 3-Phase | DH6TE09040

Daikin

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
DH6TE09040
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
35.50 (in)
Height:
41.50 (in)
Depth:
35.50 (in)

Questions about Daikin 7.5 Ton 16.0 IEER / 11.4 EER R-32 Commercial Split Heat Pump Outdoor Unit, 460V 3-Phase | DH6TE09040?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$13,883.44

  • Qualifies for FREE Shipping
5 in stock • Ships in 2-3 Business Days
Overview

Daikin 7.5 Ton 16.0 IEER / 11.4 EER R-32 Commercial Split Heat Pump Outdoor Unit, 460V 3-Phase | DH6TE09040

Daikin 7.5 Ton 16.0 IEER / 11.4 EER R-32 Commercial Split Heat Pump Outdoor Unit, 460V 3-Phase
Product details

Description

Product Summary

The Daikin DH6TE09040 is a 7.5-ton R-32 commercial split-system heat pump outdoor unit from the Daikin DH6TE0 series, built for 460V 3-Phase light commercial power. It delivers a rated 92,000 BTU/h of cooling and 85,000 BTU/h of heating at 47°F.

It is rated at 16.0 IEER and 11.4 EER, with a two-stage compressor and factory-applied R-32 charge.

Contractors use the DH6TE09040 to pair with a matched Daikin R-32 commercial air handler or coil on offices, retail spaces and other light commercial buildings that need three-phase split-system cooling and heating.

Key Features

  • R-32 refrigerant: lower global warming potential refrigerant used across the current Daikin commercial split lineup
  • Two-stage operation: two-stage compressor system for better part-load efficiency, reflected in the 16+ IEER rating
  • Commercial three-phase power: 460V 3-Phase supply with 17.9 A MCA and 20 A MOP
  • Large line connections: 1-1/8 in suction and 5/8 in liquid connections
  • Heavy-duty cabinet: 41.5 x 35.5 x 35.5 in footprint for rooftop or slab mounting
  • Heat pump heating: reversing heat pump design with 85,000 BTU/h rated heating

Ideal Applications

  • Offices and professional buildings
  • Retail stores and strip centers
  • Restaurants and light commercial kitchens (dining areas)
  • Schools, churches and community buildings
  • Light commercial retrofits replacing R-410A split systems

Frequently Asked Questions

What refrigerant does the Daikin DH6TE09040 use?

The DH6TE09040 uses R-32 refrigerant and ships with a 110 oz holding charge. Pair it only with R-32 rated indoor equipment.

What power supply does the DH6TE09040 need?

It requires 460V 3-Phase, 60 Hz power. The published minimum circuit ampacity is 17.9 A and the maximum overcurrent protection is 20 A.

What size line set does the DH6TE09040 use?

The unit has a 1-1/8 in suction connection and a 5/8 in liquid connection.

What indoor unit should I match with the DH6TE09040?

Use a Daikin R-32 commercial air handler or coil matched to 7.5 tons in the AHRI directory. Contact HVAC365 and we will help confirm the matched system.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Daikin
Width:
35.50 (in)
Height:
41.50 (in)
Depth:
35.50 (in)
Weight:
417.00 LBS
Capacity (Tons):
7.5
Refrigerant Type:
R-32
Voltage / Phase:
460V 3-Phase
Cooling Capacity (BTU):
92,000
EER:
11 EER
IEER:
16 IEER
Heating Output (BTU):
70,000 - 99,000 BTU
Heating Capacity @ 17°F (BTU):
52,000
COP @ 47°F:
3.50
Electrical Phase:
3-Phase
Electrical Frequency:
60 Hz
Minimum Circuit Ampacity (MCA):
17.9 A
Maximum Overcurrent Protection (MOP):
20 A
Breaker Size (Amps):
20
Number of Compressors:
2
Compressor Type:
Tandem
Compressor Stages:
Two Stage
Refrigerant Charge (oz):
110
Sound Level (dB):
83
Shipping Weight:
417 lb
Product Height:
41.5 in
Product Width:
35.5 in
Product Depth:
35.5 in
Product Line:
DH6TE
Package Type:
Heat Pump
Product Category:
Heat Pump Condenser
DOE Regional Compliance:
Nationwide
Model Number:
DH6TE09040
Nominal Capacity:
7.5 Tons
Rated Cooling Capacity:
92,000 BTU/h
Rated Heating Capacity (47°F):
85,000 BTU/h
Heating COP:
3.5
Compressor:
Two-stage
Holding Charge:
110 oz
Suction Line Connection:
1-1/8 in
Liquid Line Connection:
5/8 in
Unit Dimensions (H x W x D):
41.5 x 35.5 x 35.5 in
Unit Weight:
386 lb
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
5 Years Parts | Registration Required within 60 Days of Purchase
Frequently asked questions
What size is the ?
The is a 7.5 ton unit.
What refrigerant does the use?
It uses R-32 refrigerant.
What power supply does the need?
It requires 460V 3-Phase power.
How much cooling does the provide?
It is rated for 92,000 BTU of cooling.
What warranty comes with the DH6TE09040?
5 Years Parts | Registration Required within 60 Days of Purchase
Who makes the DH6TE09040?
The DH6TE09040 is made by Daikin.