Goodman 1.5 Ton 14.5 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA1810 GD9T800603AX CAPTA2422A3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA1810-GD9T800603AX-CAPTA2422A3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
26.00 (in)
Height:
27.00 (in)
Depth:
26.00 (in)

Questions about Goodman 1.5 Ton 14.5 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA1810 GD9T800603AX CAPTA2422A3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$4,156.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 1.5 Ton 14.5 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA1810 GD9T800603AX CAPTA2422A3

Goodman 1.5 Ton Air Conditioner Gas Furnace & Air Conditioner System
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA1810 outdoor air conditioner with one GD9T800603AX gas furnace and one CAPTA2422A3 evaporator coil. It is a nominal 1.5 ton ducted cooling system paired with ducted gas heat for a single air distribution path. The outdoor condenser provides refrigerant compression and heat rejection, while the indoor coil provides the evaporator heat transfer surface within the duct system. The furnace supplies combustion heat and establishes airflow across the coil using its ECM blower for cooling, heating, and circulation modes. The coil is a cased upflow/downflow evaporator coil built for upflow or downflow (vertical) installation and includes a factory TXV for controlled refrigerant metering. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control with non-communicating equipment logic.

Performance

Cooling capacity control is handled at the outdoor section, while indoor comfort depends on correct airflow setup, coil selection, and refrigerant charge. The TXV coil stabilizes metering under changing indoor load to support consistent evaporator superheat and latent performance. The furnace operates as a two-stage platform to manage heat delivery relative to load, reducing overshoot when staged operation is available. In heating mode, furnace input ranges from 42,000 to 60,000 BTU/h depending on firing stage and demand. Indoor airflow is configured at the furnace to support duct static pressure constraints while maintaining coil temperature targets. Overall system performance is achieved by coordinating refrigerant-side heat transfer at the coil with air-side delivery through the duct network.

Smart Features

Controls follow conventional 24V heat and cool call logic, supporting non-communicating thermostats and third-party smart thermostats with standard outputs. The furnace control system manages ignition sequencing, safety proving, and blower timing, with diagnostics used for troubleshooting. ECM blower speed selection enables airflow tuning for cooling and heating profiles without changing the outdoor control architecture. When applied with zoning dampers, airflow setup and duct design determine how well the system maintains coil temperature stability and zone balance. Service roles stay clear by separating refrigeration service at the outdoor unit from ignition and airflow service at the furnace section. This architecture supports typical replacement and service workflows for ducted split systems.

Comfort & Noise

Comfort is governed by coil face velocity and duct design, with cabinet widths selected so the furnace and coil align for stable air distribution. Staged furnace operation, when present, uses low fire for moderate demand and transitions to high fire when load increases. The ECM blower supports smoother airflow transitions and can be configured for continuous circulation for improved mixing and filtration through the return path. Cooling humidity performance depends on achieving intended evaporator temperature, which is sensitive to airflow setup and refrigerant charge, with the TXV helping stabilize metering. Noise behavior is strongly influenced by duct static pressure and airflow selection at the furnace rather than the refrigerant circuit alone. Overall comfort is produced by coordinated heat rejection outdoors, heat absorption at the indoor coil, and ducted air delivery through the furnace blower.

Use Case Fit

This package is suited for ducted residential applications and can support light commercial or multi-family use where one outdoor condenser serves one duct system. The furnace supports upflow or horizontal left/right installation, while the coil supports upflow or downflow (vertical) mounting to match common vertical or horizontal duct layouts. Combustion venting requirements follow the furnace platform, including PVC direct vent for condensing models and Category I venting for non-condensing models. Zoning can be applied with dampers where duct design supports stable airflow and coil temperature control in each zone. The furnace NOx classification for this model is < 40 NG/J NOx, which may support compliance requirements depending on jurisdiction. This configuration fits applications where a defined equipment set is used to deliver central cooling and ducted gas heat through one air path.

Value & Reliability

Reliability is supported by conventional split-system architecture with serviceable indoor and outdoor sections and accessible refrigerant and airflow service points. The furnace integrates safety controls for flame sensing, pressure proving, and limit protection to manage combustion operation over repeated cycles. Coil cabinet insulation and drain features support condensate management when installed with proper trapping and drainage. Airflow tuning is supported by the ECM blower, helping match coil performance to duct static and filtration requirements. Standard electrical interfaces and 24V control wiring simplify replacement and service across common installations. Across the package, the value is predictable commissioning steps focused on airflow setup, charge verification, and combustion safety validation.

Summary Wrap-Up

As a complete ducted split system, this package pairs one GLXS4BA1810 outdoor condenser with a 80% AFUE GD9T800603AX gas furnace and a TXV-metered CAPTA2422A3 evaporator coil. The outdoor condenser performs the refrigeration work, while the indoor coil provides evaporator heat transfer and the furnace supplies airflow and combustion heat. Component roles remain separated for serviceability, with refrigeration diagnostics at the condenser and ignition and airflow diagnostics at the furnace. Commissioning centers on blower airflow configuration, refrigerant charge verification, venting completion where applicable, and confirmation of ignition safety operation. For wholesale and D2C buyers, the value is a defined Goodman equipment set with conventional controls and serviceable subassemblies. Select this configuration when you need ducted central cooling paired with gas heat and clear component roles across the refrigeration and combustion sections.

Key Features

  • Split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit for central cooling.
  • Gas furnace heat section: GD9T800603AX provides ducted combustion heat with two-stage operation and integrated safeties.
  • ECM airflow delivery: ECM blower supports airflow setup for cooling, heating, and continuous circulation through the duct network.
  • TXV refrigerant metering: CAPTA2422A3 includes a factory TXV to stabilize evaporator operation under changing indoor load.
  • Mounting and orientation flexibility: Furnace supports upflow or horizontal left/right installation and the coil supports upflow or downflow (vertical) mounting.
  • Application fit: Matched sizing supports typical residential duct systems where one outdoor unit serves one distribution path.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
26.00 (in)
Height:
27.00 (in)
Depth:
26.00 (in)
Weight:
156.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Category:
Gas Heating & Air Conditioner Bundle
AFUE:
80%
AHRI Reference Number:
215214563
Cabinet Width (in):
14
Airflow (CFM):
1,200
EER2:
12 EER2
Capacity (Tons):
1.5
Color:
Gray
Blower Motor Type:
ECM Constant Torque
Configuration:
Downflow
Vent Type:
Chimney / Category I
SEER2:
14 SEER2
Shipping Weight:
276 lb
Electrical Frequency:
60 Hz
Prop 65 Warning:
Yes
Liquid Line Size:
3/8 in
Refrigerant Type:
R-32
Electrical Phase:
1-Phase
Unit Weight:
246 lb
Heating Input (BTU):
40,000 - 69,000 BTU
Line Set Connection Type:
Braze
Heating Stages:
Two Stage
AHRI Certified:
Yes
Cooling Capacity (BTU):
18,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA1810 - Nominal Capacity (Tons):
1.5
Condenser GLXS4BA1810 - Cooling Capacity (BTU/h):
18,000
Condenser GLXS4BA1810 - Refrigerant:
R-32
Condenser GLXS4BA1810 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA1810 - Minimum Circuit Ampacity (MCA):
10.9 A
Condenser GLXS4BA1810 - Maximum Overcurrent Protection (MOP):
15 A
Condenser GLXS4BA1810 - Compressor Type:
Rotary
Condenser GLXS4BA1810 - Compressor Stages:
Single Stage
Condenser GLXS4BA1810 - Liquid Line Size:
3/8 in
Condenser GLXS4BA1810 - Suction Line Size:
3/4 in
Condenser GLXS4BA1810 - Sound Level (dB):
74
Condenser GLXS4BA1810 - Unit Dimensions (W x D x H):
26 in x 26 in x 27 in
Condenser GLXS4BA1810 - Unit Weight:
117 lb
Condenser GLXS4BA1810 - Shipping Weight:
132 lb
Furnace GD9T800603AX - Input (BTU/h):
60,000
Furnace GD9T800603AX - Output (BTU/h):
48,000
Furnace GD9T800603AX - AFUE:
80%
Furnace GD9T800603AX - Heating Stages:
Two Stage
Furnace GD9T800603AX - Blower Motor Type:
ECM Constant Torque
Furnace GD9T800603AX - Maximum Cooling Capacity (Tons):
4
Furnace GD9T800603AX - Configuration:
Downflow/Horizontal
Furnace GD9T800603AX - Cabinet Width:
14 in
Furnace GD9T800603AX - Vent Type:
Chimney / Category I
Furnace GD9T800603AX - Gas Type:
Propane Convertible
Furnace GD9T800603AX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GD9T800603AX - Unit Dimensions (W x D x H):
14 in x 28 in x 12.5 in
Furnace GD9T800603AX - Shipping Weight:
107 lb
Evaporator Coil CAPTA2422A3 - Nominal Capacity (Tons):
2
Evaporator Coil CAPTA2422A3 - Cased/Uncased:
Cased
Evaporator Coil CAPTA2422A3 - Configuration:
Upflow/Downflow
Evaporator Coil CAPTA2422A3 - Cabinet Width:
14 in
Evaporator Coil CAPTA2422A3 - Metering Device:
TXV
Evaporator Coil CAPTA2422A3 - Refrigerant:
R-32
Evaporator Coil CAPTA2422A3 - Liquid Line Size:
3/8 in
Evaporator Coil CAPTA2422A3 - Suction Line Size:
3/4 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What is the AFUE of the ?
The is rated at 80% AFUE.
Is the AHRI certified?
Yes. The AHRI reference number is 215214563.
What size is the ?
The is a 1.5 ton unit.
What is the SEER2 rating of the ?
The is rated at 14 SEER2 SEER2.
What refrigerant does the use?
It uses R-32 refrigerant.
What is the heating input of the ?
The heating input is 40,000 - 69,000 BTU BTU.
How much cooling does the provide?
It is rated for 18,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA1810-GD9T800603AX-CAPTA2422A3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA1810-GD9T800603AX-CAPTA2422A3?
The GLXS4BA1810-GD9T800603AX-CAPTA2422A3 is made by Goodman.