Description
The Goodman 2 Ton 14.3 SEER2 96% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 (GLXS4BA2410 / GD9T960803BN / CAPTA2422B3) is a complete residential heating and cooling system designed to provide reliable year-round comfort with high-efficiency heating performance and dependable cooling operation. This matched split system combines a 2-ton R-32 air conditioner condenser, cased evaporator coil, and 96% AFUE gas furnace to deliver efficient climate control for residential applications.
The included CAPTA2422B3 cased evaporator coil is designed for R-32 refrigerant applications and supports upflow/downflow installation configurations with a factory-installed TXV expansion device for improved refrigerant control and efficient system performance.
Built with Goodman’s reliable HVAC components, two-stage heating operation, 9-speed ECM blower technology, and downflow installation flexibility, the GLXS4BA2410 / GD9T960803BN / CAPTA2422B3 system is an excellent choice for residential replacement projects and new HVAC installations requiring efficient heating and cooling performance.
Key Features
- Complete Heating & Cooling System – Includes outdoor condenser, evaporator coil, and gas furnace
- 2 Ton Cooling Capacity – Provides 24,000 BTU cooling performance for residential applications
- 14.3 SEER2 Efficiency Rating – Helps improve cooling efficiency and reduce energy consumption
- 80,000 BTU Gas Furnace – Provides powerful heating capacity for residential comfort
- 96% AFUE High-Efficiency Furnace – Converts more fuel into usable heat for improved efficiency
- Two-Stage Gas Furnace Operation – Provides more consistent heating and improved comfort
- R-32 Refrigerant Compatible – Uses modern refrigerant technology
System Components Included
Goodman GLXS4BA2410 Air Conditioner Condenser
- Capacity: 2 Ton / 24,000 BTU
- Efficiency: 14.3 SEER2
- Operation: Single Stage
- Refrigerant: R-32
- Compressor Type: Single Stage
- Voltage: 208/230V, 1 Phase
- Liquid Line: 3/8"
- Suction Line: 3/4"
- Application: Split Air Conditioning System
Goodman CAPTA2422B3 Evaporator Coil
- Type: Cased Evaporator Coil
- Capacity: 2 Ton Application
- Configuration: Upflow / Downflow Compatible
- Refrigerant: R-32 Compatible
- Expansion Device: Factory Installed TXV
- Cabinet Width: 17.5"
- Application: Matched Indoor Coil
Goodman GD9T960803BN Gas Furnace
- Heating Input: 80,000 BTU
- Efficiency: 96% AFUE
- Operation: Two Stage
- Blower Motor: 9-Speed ECM
- Configuration: Downflow / Horizontal Compatible
- Heating Output: Approximately 76,800 BTU
- Fuel Type: Natural Gas
- Application: Residential Heating
Compatibility / Installation Notes
The Goodman GLXS4BA2410 GD9T960803BN CAPTA2422B3 System is designed for:
- Residential Cooling Applications
- Residential Gas Heating Applications
- Downflow Furnace Installations
- Horizontal Installation Options
- Split HVAC System Applications
- R-32 Refrigerant Systems
- Replacement and New Construction Projects
Specifications:
- Brand: Goodman
- Model Combination: GLXS4BA2410 / GD9T960803BN / CAPTA2422B3
- System Type: Gas Electric Split System
- Cooling Capacity: 2 Ton (24,000 BTU)
- Heating Input: 80,000 BTU
- Heating Output: Approximately 76,800 BTU
- Cooling Efficiency: 14.3 SEER2
- Heating Efficiency: 96% AFUE
Installation Notes
- Verify compatibility with existing ductwork, electrical requirements, and gas connections before installation
- Confirm airflow direction and furnace orientation before installation
- Check refrigerant line sizing requirements
- Ensure proper PVC venting requirements for the 96% AFUE furnace
- Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What is included in this Goodman HVAC system?
This package includes the GLXS4BA2410 air conditioner condenser, CAPTA2422B3 evaporator coil, and GD9T960803BN gas furnace.
What is the cooling capacity of this system?
The system provides 2 tons (24,000 BTU) of cooling capacity.
What is the furnace heating capacity?
The furnace provides 80,000 BTU input with 96% AFUE efficiency, producing approximately 76,800 BTU heating output.
What refrigerant does this system use?
The air conditioning system uses R-32 refrigerant.
Can this system be installed in a downflow configuration?
Yes. This system is designed for downflow installation applications with compatible indoor components.
Is this a complete HVAC system?
Yes. It includes the outdoor condenser, indoor evaporator coil, and gas furnace required for a complete gas-electric heating and cooling system.
Videos
-
Goodman Air Conditioning and Heating - Built In America | HVAC365
In this episode of HVAC365, we take a closer look at Goodman, ...
-
Goodman Manufacturing's Headquarters An Exclusive Look Inside | Military Makeover with Montel
Join us for an exclusive tour inside Goodman Manufacturing's h...
-
Inside the Goodman Brand: A Comprehensive Tour of HVAC Excellence | HVAC365
Step into the world of HVAC excellence with an immersive journ...
-
Operation Comfort: Installing a Goodman HVAC System for a Veteran's Home Makeover | HVAC365
"Operation Comfort" showcases the transformation of a veteran'...
-
Maximizing Comfort: A Goodman Heating and Cooling System Installation | HVAC365
In this episode of HVAC365, join us as we delve into the insta...