Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S800804BN CAPTA3626B3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA3610-GD9S800804BN-CAPTA3626B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)

Questions about Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S800804BN CAPTA3626B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$4,825.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S800804BN CAPTA3626B3

Goodman 3 Ton 14.5 SEER2 80% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Downflow R-32, model GLXS4BA3610 GD9S800804BN CAPTA3626B3 - view 5
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610A R-32 outdoor air conditioner with one GD9S800804BN GD9S80 gas furnace and one CAPTA3626B3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system paired with an 80% AFUE forced-air gas heat section for ducted whole-home distribution. The outdoor unit uses R-32 refrigerant and is factory charged for 15 feet of interconnecting tubing to support standard installation practices. The indoor furnace is a single-stage platform with a nine-speed ecm blower that provides system airflow across the coil and through the duct system. The coil is a cased upflow/downflow evaporator coil designed for upflow or downflow (vertical) mounting to match common upflow/downflow furnace applications. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control.

Performance

Cooling performance is driven by a single-stage scroll and condenser fan that cycle to match thermostat demand. The GLXS4B series is rated up to 15.2 SEER2 with realized efficiency dependent on the matched indoor coil, airflow setup, and installation conditions. Refrigerant connections use 0.38" liquid and 0.88" suction service valves consistent with typical 3 ton line-set sizing. Indoors, the furnace blower is configured to deliver target CFM for cooling and heating while managing duct static pressure within system limits. The evaporator coil completes the refrigerant circuit indoors and provides heat transfer for both sensible and latent capacity when charge and airflow are set correctly. In heating mode, the furnace delivers approximately 64,000 BTU/h output at rated input, with combustion airflow managed by an induced-draft venting system.

Smart Features

Controls follow conventional 24V staging logic, supporting widely used non-communicating thermostats and control panels. The furnace control board provides self-diagnostics and coordinates ignition, safeties, and blower timing for consistent starts and shutdowns. The nine-speed ECM blower enables selectable airflow profiles for cooling, heating, and continuous fan operation without changing the outdoor control architecture. When applied with zoning dampers, blower speed options can be matched to zoning design and required airflow to avoid excessive coil temperature drop or noise. The outdoor section uses standard contactor-based control and integrates refrigeration safety devices to interrupt operation under abnormal pressure conditions. This split architecture keeps service access clear by separating refrigerant service at the condenser from combustion and airflow service at the furnace and coil.

Comfort & Noise

Outdoor sound performance is supported by a published 67 dBA rating for the 3 ton chassis to help manage exterior noise near patios and lot lines. Because the furnace is single stage, temperature stability in heating relies on thermostat cycle rate, duct losses, and blower setup rather than staged firing. The ECM blower supports smoother airflow transitions and can be configured for lower continuous circulation speeds for improved mixing. Cooling comfort is governed by coil selection and airflow balance, with the coil cabinet size aligned to typical furnace widths for stable face velocity. Humidity control is achieved through correct airflow and refrigerant charge so the evaporator operates at the intended temperature and latent capacity. Overall comfort is produced by coordinated capacity at the outdoor condenser, heat transfer at the indoor coil, and controlled duct airflow from the furnace.

Use Case Fit

This package is suited for ducted residential applications and can also support light commercial or multi-family use where a single outdoor condenser serves one duct system. The GD9S80 furnace is built for downflow or horizontal left/right installation, supporting utility closets and horizontal runs when vertical space is constrained. The CAPTA coil supports upflow or downflow (vertical) mounting for common upflow/downflow furnace layouts and closet installations. R-32 refrigerant is used for the refrigeration circuit, and installation should follow applicable A2L handling practices and local code requirements. The furnace NOx classification for this model is > 40 NG/J NOx (N code), which may support compliance requirements in regulated air districts depending on jurisdiction. This configuration fits mixed-humid and hot-humid climates where correct airflow and coil selection are used to manage seasonal latent and sensible loads.

Value & Reliability

Reliability is supported by outdoor components including a factory-installed filter drier, sweat service valves, an enclosed contactor, and a high-pressure switch. The outdoor cabinet uses steel louvers and a coil guard to reduce incidental damage while maintaining condenser airflow. The furnace cabinet is heavy-gauge steel and integrates safety controls for flame sensing, pressure proving, and limit protection. Multi-position service access and left/right utility connections support practical field routing for gas and electrical service. The coil cabinet provides a dedicated condensate drain interface and insulated casing to help manage cabinet sweating and condensate formation. Across the package, standard electrical requirements and common cabinet widths support routine maintenance and parts availability.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with an 80% AFUE GD9S80 single-stage gas furnace and a CAPTA cased evaporator coil to cover both cooling and heating seasons. The outdoor condenser provides the refrigeration work while the furnace supplies airflow, filtration interface, and combustion heat. The indoor coil completes the refrigerant circuit and is sized to match cabinet width for controlled air distribution across the heat transfer surface. For contractors, commissioning is centered on airflow setup, refrigerant charge verification, and confirmation of ignition and safety operation. For D2C and wholesale buyers, this configuration provides a defined Goodman equipment set with standard controls and conventional serviceability. Select this package when you need a conventional ducted AC plus gas furnace system with clear component roles and field-configurable airflow.

Key Features

  • R-32 split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage scroll compression: Outdoor unit cycles as a single-stage system to deliver nominal 3 ton capacity under thermostat control.
  • Factory charge allowance: Outdoor section is factory charged for 15 ft of line set to support typical installation lengths.
  • Single-stage induced-draft gas heat: GD9S800804BN furnace provides 80,000 BTU/h input with induced-draft venting and integrated safety controls.
  • Nine-speed ECM airflow control: Selectable blower speeds support airflow tuning for cooling, heating, and continuous circulation modes.
  • Multi-position indoor installation: Furnace supports downflow or horizontal left/right, and the CAPTA coil supports vertical upflow/downflow mounting.
  • Service and protection devices: Filter drier, sweat service valves, enclosed contactor, and high-pressure switch support commissioning and refrigeration protection.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)
Weight:
415.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Category:
Gas Heating & Air Conditioner Bundle
Heating Stages:
Single Stage
Heating Input (BTU):
70,000 - 99,000 BTU
Liquid Line Size:
3/8 in
Line Set Connection Type:
Braze
Unit Weight:
298 lb
Electrical Frequency:
60 Hz
EER2:
12 EER2
Electrical Phase:
1-Phase
Vent Type:
Chimney / Category I
Refrigerant Type:
R-32
Shipping Weight:
328 lb
SEER2:
14 SEER2
Prop 65 Warning:
Yes
Cabinet Width (in):
17.5
Color:
Gray
Airflow (CFM):
1,600
AHRI Reference Number:
214859875
Blower Motor Type:
ECM Constant Torque
Capacity (Tons):
3
Configuration:
Downflow
AFUE:
80%
AHRI Certified:
Yes
Cooling Capacity (BTU):
36,000
EER:
12
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA3610 - Nominal Capacity (Tons):
3
Condenser GLXS4BA3610 - Cooling Capacity (BTU/h):
36,000
Condenser GLXS4BA3610 - Refrigerant:
R-32
Condenser GLXS4BA3610 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA3610 - Minimum Circuit Ampacity (MCA):
17.8 A
Condenser GLXS4BA3610 - Maximum Overcurrent Protection (MOP):
30 A
Condenser GLXS4BA3610 - Compressor Type:
Scroll
Condenser GLXS4BA3610 - Compressor Stages:
Single Stage
Condenser GLXS4BA3610 - Liquid Line Size:
3/8 in
Condenser GLXS4BA3610 - Suction Line Size:
7/8 in
Condenser GLXS4BA3610 - Sound Level (dB):
67
Condenser GLXS4BA3610 - Unit Dimensions (W x D x H):
29 in x 29 in x 39.5 in
Condenser GLXS4BA3610 - Unit Weight:
158 lb
Condenser GLXS4BA3610 - Shipping Weight:
173 lb
Furnace GD9S800804BN - Input (BTU/h):
80,000
Furnace GD9S800804BN - Output (BTU/h):
64,000
Furnace GD9S800804BN - AFUE:
80%
Furnace GD9S800804BN - Heating Stages:
Single Stage
Furnace GD9S800804BN - Blower Motor Type:
ECM Constant Torque
Furnace GD9S800804BN - Maximum Cooling Capacity (Tons):
4
Furnace GD9S800804BN - Configuration:
Downflow/Horizontal
Furnace GD9S800804BN - Cabinet Width:
17.5 in
Furnace GD9S800804BN - Vent Type:
Chimney / Category I
Furnace GD9S800804BN - Gas Type:
Propane Convertible
Furnace GD9S800804BN - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GD9S800804BN - Unit Dimensions (W x D x H):
17.5 in x 28 in x 33.375 in
Furnace GD9S800804BN - Shipping Weight:
107 lb
Evaporator Coil CAPTA3626B3 - Nominal Capacity (Tons):
3
Evaporator Coil CAPTA3626B3 - Cased/Uncased:
Cased
Evaporator Coil CAPTA3626B3 - Configuration:
Upflow/Downflow
Evaporator Coil CAPTA3626B3 - Cabinet Width:
17.5 in
Evaporator Coil CAPTA3626B3 - Metering Device:
TXV
Evaporator Coil CAPTA3626B3 - Refrigerant:
R-32
Evaporator Coil CAPTA3626B3 - Liquid Line Size:
3/8 in
Evaporator Coil CAPTA3626B3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What is the heating input of the ?
The heating input is 70,000 - 99,000 BTU BTU.
What refrigerant does the use?
It uses R-32 refrigerant.
What is the SEER2 rating of the ?
The is rated at 14 SEER2 SEER2.
Is the AHRI certified?
Yes. The AHRI reference number is 214859875.
What size is the ?
The is a 3 ton unit.
What is the AFUE of the ?
The is rated at 80% AFUE.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA3610-GD9S800804BN-CAPTA3626B3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA3610-GD9S800804BN-CAPTA3626B3?
The GLXS4BA3610-GD9S800804BN-CAPTA3626B3 is made by Goodman.