Goodman 3 Ton 14.5 SEER2 96% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S960603BN CAPTA3626B3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA3610-GD9S960603BN-CAPTA3626B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)

Questions about Goodman 3 Ton 14.5 SEER2 96% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S960603BN CAPTA3626B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$5,317.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 3 Ton 14.5 SEER2 96% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32 | GLXS4BA3610 GD9S960603BN CAPTA3626B3

Goodman 3 Ton 14.5 SEER2 96% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Downflow R-32, model GLXS4BA3610 GD9S960603BN CAPTA3626B3 - view 5
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610 R-32 outdoor air conditioner with one GD9S960603BN GD9S96 gas furnace and one CAPTA3626B3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system paired with a 96% AFUE forced-air gas heat section for ducted whole-building distribution. The outdoor unit uses R-32 refrigerant and is designed for conventional split-system line-set and metering control through the matched indoor coil. The indoor furnace is a single-stage condensing platform that provides combustion heat while the 9-speed ECM blower delivers airflow across the coil and through the duct system. The coil is a cased upflow/downflow evaporator coil designed for upflow or downflow (vertical) mounting and includes a factory TXV to meter refrigerant at the indoor heat exchanger. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control with non-communicating equipment logic.

Performance

Cooling performance is driven by a single-stage outdoor refrigeration circuit rated up to 15.2 SEER2, with realized efficiency dependent on coil match, airflow setup, and installation conditions. The outdoor section uses 0.375" liquid and 0.875" suction service valves to align with typical 3 ton line-set sizing and refrigerant service practices. Indoors, the furnace blower is configured to deliver target CFM for cooling and heating while managing duct static pressure within system limits. The TXV-equipped coil stabilizes refrigerant metering under changing indoor load to support consistent evaporator superheat and reliable latent capacity. In heating mode, the furnace delivers approximately 57,660 BTU/h output at 60,000 BTU/h input, using a condensing heat exchanger and direct-vent combustion air strategy when applied as a two-pipe system. System capacity and discharge temperature are ultimately governed by thermostat demand, airflow configuration, and proper refrigerant charging at startup.

Smart Features

Controls follow conventional 24V call logic, supporting widely used non-communicating thermostats and third-party smart thermostats that provide standard heat/cool outputs. The furnace control board coordinates ignition sequence, safety proving, and blower timing, and it supports onboard diagnostics for service troubleshooting. The 9-speed ECM blower enables selectable airflow profiles for cooling, heating, and continuous fan operation without changing the outdoor control architecture. When applied with zoning dampers, blower speed selection and duct design determine how well the system maintains coil temperature, airflow balance, and noise control across zones. The outdoor section uses contactor-based operation and integrated refrigeration safety devices to interrupt operation under abnormal conditions. This split architecture keeps service roles clear by separating refrigerant service at the condenser from combustion, condensate, and airflow service at the furnace and coil.

Comfort & Noise

Outdoor acoustic performance is supported by a published 67 dBA rating for the 3 ton chassis to help manage exterior noise at the placement location. Because the furnace is single stage, heating temperature stability is primarily determined by thermostat cycle rate, duct losses, and airflow configuration rather than staged firing. The ECM blower supports smoother airflow transitions and can be configured for lower continuous circulation speeds for improved mixing and filtration through the return path. Cooling comfort is governed by coil sizing and airflow balance, with cabinet width matching used to control face velocity across the indoor heat exchanger. Humidity performance depends on achieving the intended evaporator temperature through correct airflow and refrigerant charge, with the TXV helping maintain stable metering. Overall comfort is produced by coordinated heat rejection at the outdoor coil, heat absorption at the indoor coil, and ducted air delivery through the furnace blower.

Use Case Fit

This package is suited for ducted residential applications and can support light commercial or multi-family use where one outdoor condenser serves one duct system. The furnace supports downflow or horizontal left/right installation, which helps in utility closets and horizontal runs when vertical space or duct routing is constrained. The CAPTA3626B3 coil supports upflow or downflow (vertical) mounting for common upflow or downflow furnace layouts and closet installations. The condensing furnace uses PVC venting and can be configured as 1-pipe (exhaust only) or 2-pipe (dedicated combustion air) depending on installation design and code requirements. R-32 refrigerant is used for the refrigeration circuit, and installation should follow applicable A2L handling practices and local code requirements. This configuration fits mixed-humid and hot-humid climates where airflow control and coil selection are used to manage seasonal sensible and latent loads.

Value & Reliability

Reliability is supported by outdoor components commonly used in serviceable split systems, including accessible service valves for charging and diagnostics. The outdoor cabinet and fan system are designed to maintain condenser airflow while protecting the coil face from incidental impact. The furnace integrates safety controls for flame sensing, pressure proving, and limit protection to manage combustion operation over repeated cycles. Condensate management is handled at the furnace and coil through dedicated drain interfaces that should be trapped and routed per installation standards. Standard electrical requirements and conventional 24V controls support straightforward replacement, service, and thermostat integration. Across the package, the component roles remain distinct, which helps isolate troubleshooting between refrigerant-side and combustion/airflow-side service tasks.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with a 96% AFUE GD9S96 single-stage gas furnace and a TXV-metered CAPTA3626B3 cased coil to provide cooling and gas heat in one matched architecture. The outdoor condenser performs the refrigeration work, while the indoor coil provides the evaporator heat transfer surface and the furnace supplies airflow and combustion heat. Cabinet widths are selected so the furnace and coil align for practical installation and stable air distribution across the coil face. For contractors, commissioning focuses on blower airflow setup, refrigerant charge verification, venting/condensate completion, and verification of ignition and safety operation. For wholesale and D2C buyers, the value is a defined Goodman equipment set that uses standard controls, serviceable components, and conventional split-system architecture. Select this configuration when you need ducted central cooling with a condensing gas furnace and clear component roles across the refrigeration and combustion sections.

Key Features

  • R-32 split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage cooling operation: Outdoor section cycles to thermostat demand to deliver nominal 3 ton capacity with conventional non-communicating controls.
  • Condensing gas heat section: GD9S960603BN furnace provides 60,000 BTU/h input with direct-vent PVC exhaust and condensate handling requirements.
  • AFUE efficiency rating: 96% AFUE furnace efficiency supports reduced flue losses compared to non-condensing platforms.
  • 9-speed ECM airflow management: Selectable blower speeds support airflow tuning for cooling, heating, and continuous circulation modes.
  • TXV-metered evaporator coil: CAPTA3626B3 coil includes a factory-installed TXV for controlled refrigerant metering and stable evaporator operation.
  • Multi-position indoor installation: Furnace supports downflow or horizontal left/right, and the coil supports vertical upflow/downflow mounting for common duct layouts.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
48.00 (in)
Height:
42.00 (in)
Depth:
40.00 (in)
Weight:
424.00 LBS
Product Category:
Gas Heating & Air Conditioner Bundle
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Airflow (CFM):
1,200
Blower Motor Type:
ECM Constant Torque
Cabinet Width (in):
17.5
AHRI Reference Number:
214859868
AFUE:
96%+
Electrical Frequency:
60 Hz
Heating Stages:
Single Stage
Line Set Connection Type:
Braze
Heating Input (BTU):
40,000 - 69,000 BTU
Configuration:
Downflow
Capacity (Tons):
3
EER2:
12 EER2
Electrical Phase:
1-Phase
Color:
Gray
Unit Weight:
307 lb
Vent Type:
PVC / Category IV
Prop 65 Warning:
Yes
SEER2:
14 SEER2
Shipping Weight:
337 lb
Liquid Line Size:
3/8 in
Refrigerant Type:
R-32
AHRI Certified:
Yes
EER:
12
Cooling Capacity (BTU):
36,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA3610 - Nominal Capacity (Tons):
3
Condenser GLXS4BA3610 - Cooling Capacity (BTU/h):
36,000
Condenser GLXS4BA3610 - Refrigerant:
R-32
Condenser GLXS4BA3610 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA3610 - Minimum Circuit Ampacity (MCA):
17.8 A
Condenser GLXS4BA3610 - Maximum Overcurrent Protection (MOP):
30 A
Condenser GLXS4BA3610 - Compressor Type:
Scroll
Condenser GLXS4BA3610 - Compressor Stages:
Single Stage
Condenser GLXS4BA3610 - Liquid Line Size:
3/8 in
Condenser GLXS4BA3610 - Suction Line Size:
7/8 in
Condenser GLXS4BA3610 - Sound Level (dB):
67
Condenser GLXS4BA3610 - Unit Dimensions (W x D x H):
29 in x 29 in x 39.5 in
Condenser GLXS4BA3610 - Unit Weight:
158 lb
Condenser GLXS4BA3610 - Shipping Weight:
173 lb
Furnace GD9S960603BN - Input (BTU/h):
60,000
Furnace GD9S960603BN - Output (BTU/h):
57,660
Furnace GD9S960603BN - AFUE:
96%+
Furnace GD9S960603BN - Heating Stages:
Single Stage
Furnace GD9S960603BN - Blower Motor Type:
ECM Constant Torque
Furnace GD9S960603BN - Maximum Cooling Capacity (Tons):
3
Furnace GD9S960603BN - Configuration:
Downflow/Horizontal
Furnace GD9S960603BN - Cabinet Width:
17.5 in
Furnace GD9S960603BN - Vent Type:
PVC / Category IV
Furnace GD9S960603BN - Gas Type:
Propane Convertible
Furnace GD9S960603BN - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GD9S960603BN - Unit Dimensions (W x D x H):
17.5 in x 28.75 in x 24.5 in
Furnace GD9S960603BN - Shipping Weight:
116 lb
Evaporator Coil CAPTA3626B3 - Nominal Capacity (Tons):
3
Evaporator Coil CAPTA3626B3 - Cased/Uncased:
Cased
Evaporator Coil CAPTA3626B3 - Configuration:
Upflow/Downflow
Evaporator Coil CAPTA3626B3 - Cabinet Width:
17.5 in
Evaporator Coil CAPTA3626B3 - Metering Device:
TXV
Evaporator Coil CAPTA3626B3 - Refrigerant:
R-32
Evaporator Coil CAPTA3626B3 - Liquid Line Size:
3/8 in
Evaporator Coil CAPTA3626B3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
Is the AHRI certified?
Yes. The AHRI reference number is 214859868.
What is the AFUE of the ?
The is rated at 96%+ AFUE.
What is the heating input of the ?
The heating input is 40,000 - 69,000 BTU BTU.
What size is the ?
The is a 3 ton unit.
What is the SEER2 rating of the ?
The is rated at 14 SEER2 SEER2.
What refrigerant does the use?
It uses R-32 refrigerant.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA3610-GD9S960603BN-CAPTA3626B3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA3610-GD9S960603BN-CAPTA3626B3?
The GLXS4BA3610-GD9S960603BN-CAPTA3626B3 is made by Goodman.