Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9S800604BX CHPTA3630B3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA3610-GR9S800604BX-CHPTA3630B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)

Questions about Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9S800604BX CHPTA3630B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$4,614.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9S800604BX CHPTA3630B3

Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32, model GLXS4BA3610 GR9S800604BX CHPTA3630B3 - view 5
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610 R-32 outdoor air conditioner with one GR9S800604BX GR9S80 gas furnace and one CHPTA3630B3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system paired with an 80% AFUE forced-air gas heat section for ducted distribution. The outdoor condenser uses R-32 refrigerant and is designed for conventional split-system line-set connections to the matched indoor coil. The indoor furnace is a single-stage platform with a 9-speed ECM blower that provides system airflow across the coil and through the duct system. The coil is a cased horizontal a-coil (evaporator coil) built for horizontal installation and includes a factory TXV for controlled refrigerant metering. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control with non-communicating equipment logic.

Performance

Cooling performance is driven by a single-stage scroll and condenser fan that cycle to match thermostat demand. The GLXS4B series is rated up to 15.2 SEER2, with realized efficiency dependent on the matched coil, blower configuration, and installation conditions. Refrigerant connections use 0.375" liquid and 0.875" suction service valves consistent with typical 3 ton line-set sizing. Indoors, the furnace blower can be configured for target airflow to support the coil’s heat transfer and duct static pressure limitations. The TXV coil stabilizes refrigerant metering under changing indoor load to support consistent evaporator superheat and latent capacity. In heating mode, the furnace delivers approximately 48,000 BTU/h output at 60,000 BTU/h input, with induced draft venting and integrated combustion safeties.

Smart Features

Controls follow standard 24V heat/cool call logic, supporting widely used non-communicating thermostats and third-party smart thermostats that provide conventional outputs. The furnace control board coordinates ignition sequence, safety proving, and blower timing, and it supports onboard diagnostics for service troubleshooting. The 9-speed ECM blower enables selectable airflow profiles for cooling, heating, and continuous fan operation without changing the outdoor control architecture. When applied with zoning dampers, blower speed selection and duct design determine how well the system maintains airflow balance and coil temperature across zones. The outdoor section uses contactor-based operation and integrated refrigeration safety devices to interrupt operation under abnormal conditions. This split architecture keeps service roles clear by separating refrigerant service at the condenser from ignition, airflow, and condensate service at the indoor section.

Comfort & Noise

Outdoor acoustic performance is supported by a published 67 dBA rating for the 3 ton chassis to help manage exterior noise at the placement location. Because the furnace is single stage, heating temperature stability is primarily determined by thermostat cycle rate, duct losses, and airflow configuration rather than staged firing. The ECM blower supports smoother airflow transitions and can be configured for lower continuous circulation speeds for improved mixing and filtration through the return path. Cooling comfort is governed by coil sizing and airflow balance, with cabinet width matching used to control face velocity across the indoor heat exchanger. Humidity performance depends on achieving the intended evaporator temperature through correct airflow and refrigerant charge, with the TXV helping maintain stable metering. Overall comfort is produced by coordinated heat rejection at the outdoor coil, heat absorption at the indoor coil, and ducted air delivery through the furnace blower.

Use Case Fit

This package is suited for ducted residential applications and can support light commercial or multi-family use where one outdoor condenser serves one duct system. The GR9S80 furnace supports upflow or horizontal left/right installation to accommodate utility closets and horizontal runs when vertical space is constrained. The CHPTA3630B3 coil supports horizontal mounting to match common vertical or horizontal duct layouts. R-32 refrigerant is used for the refrigeration circuit, and installation should follow applicable A2L handling practices and local code requirements. The furnace NOx classification for this model is < 40 NG/J NOx, which may support compliance requirements in regulated air districts depending on jurisdiction. This configuration fits mixed-humid and hot-humid climates where airflow setup and coil selection are used to manage seasonal sensible and latent loads.

Value & Reliability

Reliability is supported by outdoor components including a factory-installed filter drier, accessible service valves, and refrigeration safety devices used for protection and diagnostics. The outdoor cabinet and louvered construction are designed to maintain condenser airflow while protecting the coil face from incidental impact. The furnace integrates safety controls for flame sensing, pressure proving, and limit protection to manage combustion operation over repeated cycles. Airflow tuning is supported by the 9-speed ECM blower and a cabinet width matched to the selected evaporator coil for stable air distribution. The coil cabinet provides a dedicated condensate drain interface and insulated casing to help manage cabinet sweating and condensate formation. Across the package, standard electrical requirements and conventional 24V controls support straightforward replacement and service workflows.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with an 80% AFUE GR9S800604BX GR9S80 single-stage gas furnace and a TXV-metered CHPTA3630B3 evaporator coil to provide cooling and gas heat in one matched architecture. The outdoor condenser performs the refrigeration work, while the indoor coil provides the evaporator heat transfer surface and the furnace supplies airflow and combustion heat. Cabinet widths are selected so the furnace and coil align for practical installation and stable air distribution across the coil face. For contractors, commissioning focuses on blower airflow setup, refrigerant charge verification, and confirmation of ignition and safety operation. For wholesale and D2C buyers, the value is a defined Goodman equipment set that uses standard controls, serviceable components, and conventional split-system architecture. Select this configuration when you need ducted central cooling with an 80% AFUE gas furnace and clear component roles across the refrigeration and combustion sections.

Key Features

  • R-32 split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage cooling operation: Outdoor section cycles to thermostat demand to deliver nominal 3 ton capacity with conventional non-communicating controls.
  • Single-stage induced-draft gas heat: GR9S800604BX furnace provides 60,000 BTU/h input with induced draft venting and integrated safety controls.
  • 80% AFUE heat efficiency: Non-condensing furnace design provides 80% AFUE seasonal efficiency under standardized test conditions.
  • 9-speed ECM airflow management: Selectable blower speeds support airflow tuning up to 1,600 CFM capability depending on blower configuration.
  • TXV-metered evaporator coil: CHPTA3630B3 coil includes a factory-installed TXV for controlled refrigerant metering and stable evaporator operation.
  • Multi-position indoor installation: Furnace supports upflow or horizontal left/right mounting, and the coil supports horizontal installation to match common duct layouts.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)
Weight:
332.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Airflow (CFM):
1,600
AFUE:
80%
Blower Motor Type:
ECM Constant Torque
AHRI Reference Number:
214859833
Configuration:
Horizontal
Cabinet Width (in):
17.5
Electrical Frequency:
60 Hz
Color:
Gray
Electrical Phase:
1-Phase
EER2:
12 EER2
Capacity (Tons):
3
Heating Input (BTU):
40,000 - 69,000 BTU
Heating Stages:
Single Stage
Vent Type:
Chimney / Category I
Product Category:
Gas Heating & Air Conditioner Bundle
Shipping Weight:
347 lb
Prop 65 Warning:
Yes
Liquid Line Size:
3/8 in
Refrigerant Type:
R-32
Line Set Connection Type:
Braze
Unit Weight:
317 lb
SEER2:
15 SEER2
AHRI Certified:
Yes
Cooling Capacity (BTU):
36,000
EER:
12
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA3610 - Nominal Capacity (Tons):
3
Condenser GLXS4BA3610 - Cooling Capacity (BTU/h):
36,000
Condenser GLXS4BA3610 - Refrigerant:
R-32
Condenser GLXS4BA3610 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA3610 - Minimum Circuit Ampacity (MCA):
17.8 A
Condenser GLXS4BA3610 - Maximum Overcurrent Protection (MOP):
30 A
Condenser GLXS4BA3610 - Compressor Type:
Scroll
Condenser GLXS4BA3610 - Compressor Stages:
Single Stage
Condenser GLXS4BA3610 - Liquid Line Size:
3/8 in
Condenser GLXS4BA3610 - Suction Line Size:
7/8 in
Condenser GLXS4BA3610 - Sound Level (dB):
67
Condenser GLXS4BA3610 - Unit Dimensions (W x D x H):
29 in x 29 in x 39.5 in
Condenser GLXS4BA3610 - Unit Weight:
158 lb
Condenser GLXS4BA3610 - Shipping Weight:
173 lb
Furnace GR9S800604BX - Input (BTU/h):
60,000
Furnace GR9S800604BX - Output (BTU/h):
48,000
Furnace GR9S800604BX - AFUE:
80%
Furnace GR9S800604BX - Heating Stages:
Single Stage
Furnace GR9S800604BX - Blower Motor Type:
ECM Constant Torque
Furnace GR9S800604BX - Maximum Cooling Capacity (Tons):
4
Furnace GR9S800604BX - Configuration:
Upflow/Horizontal
Furnace GR9S800604BX - Cabinet Width:
17.5 in
Furnace GR9S800604BX - Vent Type:
Chimney / Category I
Furnace GR9S800604BX - Gas Type:
Propane Convertible
Furnace GR9S800604BX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GR9S800604BX - Unit Dimensions (W x D x H):
17.5 in x 28 in x 33.375 in
Furnace GR9S800604BX - Shipping Weight:
108 lb
Evaporator Coil CHPTA3630B3 - Nominal Capacity (Tons):
3
Evaporator Coil CHPTA3630B3 - Cased/Uncased:
Cased
Evaporator Coil CHPTA3630B3 - Configuration:
Horizontal
Evaporator Coil CHPTA3630B3 - Cabinet Width:
30 in
Evaporator Coil CHPTA3630B3 - Metering Device:
TXV
Evaporator Coil CHPTA3630B3 - Refrigerant:
R-32
Evaporator Coil CHPTA3630B3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPTA3630B3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What is the AFUE of the ?
The is rated at 80% AFUE.
Is the AHRI certified?
Yes. The AHRI reference number is 214859833.
What size is the ?
The is a 3 ton unit.
What is the heating input of the ?
The heating input is 40,000 - 69,000 BTU BTU.
What refrigerant does the use?
It uses R-32 refrigerant.
What is the SEER2 rating of the ?
The is rated at 15 SEER2 SEER2.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA3610-GR9S800604BX-CHPTA3630B3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA3610-GR9S800604BX-CHPTA3630B3?
The GLXS4BA3610-GR9S800604BX-CHPTA3630B3 is made by Goodman.