Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9T800603BX CHPTA3630B3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS4BA3610-GR9T800603BX-CHPTA3630B3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)

Questions about Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9T800603BX CHPTA3630B3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$4,774.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32 | GLXS4BA3610 GR9T800603BX CHPTA3630B3

Goodman 3 Ton 15.2 SEER2 80% AFUE 60,000 BTU Gas Electric Air Conditioner Split System Horizontal R-32, model GLXS4BA3610 GR9T800603BX CHPTA3630B3 - view 5
Product details

Description

Overview

This matched Goodman split-system package combines one GLXS4BA3610 R-32 outdoor air conditioner with one GR9T800603BX gas furnace and one CHPTA3630B3 evaporator coil. It is a 3 ton, 36,000 BTU/h nominal cooling system paired with ducted gas heat for a single air distribution path. The outdoor condenser uses R-32 refrigerant and is designed for conventional split-system line-set connections to the matched indoor coil. The furnace provides two-stage combustion heat while the ECM blower establishes airflow across the evaporator coil and through the duct system. The coil is a cased horizontal a-coil (evaporator coil) built for horizontal installation and includes a factory TXV for controlled refrigerant metering. Together, these components operate as one integrated ducted cooling-and-gas-heat system using standard 24V thermostat control with non-communicating equipment logic.

Performance

Cooling performance is driven by a single-stage scroll and condenser fan that cycle to match thermostat demand. The GLXS4B series is rated up to 15.2 SEER2, with realized efficiency dependent on the matched coil, blower configuration, and installation conditions. Refrigerant connections use 0.375" liquid and 0.875" suction service valves consistent with typical 3 ton line-set sizing. In heating mode, the furnace operates in low and high fire stages from 42,000 to 60,000 BTU/h input to better track load and manage temperature rise. Indoors, airflow is configured at the furnace to support the coil’s heat transfer and the duct system’s static pressure constraints. The TXV coil stabilizes refrigerant metering under changing indoor load to support consistent evaporator superheat and latent capacity.

Smart Features

Controls follow standard 24V heat/cool call logic, supporting widely used non-communicating thermostats and third-party smart thermostats that provide conventional outputs. The furnace control system coordinates ignition sequencing, safety proving, and blower timing, and it supports onboard diagnostics for service troubleshooting. Blower speed selection is configured at the furnace to set airflow targets for cooling, heating, and continuous circulation. GR9T furnaces include provisions associated with A2L system monitoring used with R-32 equipment, supporting integration of sensor and alarm logic when applied in the system design. When applied with zoning dampers, airflow setup and duct design determine how well the system maintains coil temperature, airflow balance, and noise control across zones. This split architecture keeps service roles clear by separating refrigerant service at the condenser from combustion, airflow, and condensate service at the indoor section.

Comfort & Noise

Outdoor acoustic performance is supported by a published 67 dBA rating for the 3 ton chassis to help manage exterior noise at the placement location. Two-stage furnace operation reduces on/off cycling by using low fire for moderate demand, then stepping to high fire when load increases. The ECM blower supports smoother airflow transitions and can be configured for lower continuous circulation speeds for improved mixing and filtration through the return path. Cooling comfort is governed by coil sizing and airflow balance, with cabinet width matching used to control face velocity across the indoor heat exchanger. Humidity performance depends on achieving the intended evaporator temperature through correct airflow and refrigerant charge, with the TXV helping maintain stable metering. Overall comfort is produced by coordinated heat rejection at the outdoor coil, heat absorption at the indoor coil, and ducted air delivery through the furnace blower.

Use Case Fit

This package is suited for ducted residential applications and can support light commercial or multi-family use where one outdoor condenser serves one duct system. The furnace supports upflow or horizontal left/right installation, while the coil supports horizontal mounting to match common vertical or horizontal duct layouts. R-32 refrigerant is used for the refrigeration circuit, and installation should follow applicable A2L handling practices and local code requirements. For GR9T96 configurations, the furnace uses PVC venting and can be configured as 1-pipe (exhaust only) or 2-pipe (dedicated combustion air) depending on installation design and code requirements. For GR9T80 configurations, venting is Category I non-condensing and combustion air requirements are governed by the installation environment and applicable codes. The furnace NOx classification for this model is < 40 NG/J NOx, which may support compliance requirements in regulated air districts depending on jurisdiction.

Value & Reliability

Reliability is supported by outdoor components including a factory-installed filter drier, accessible service valves, and refrigeration safety devices used for protection and diagnostics. The outdoor cabinet and louvered construction are designed to maintain condenser airflow while protecting the coil face from incidental impact. The furnace integrates safety controls for flame sensing, pressure proving, and limit protection to manage combustion operation over repeated cycles. Coil cabinet insulation and drain pan features support condensate management when installed with proper trapping and drainage. Airflow tuning is supported by the ECM blower and a cabinet width matched to the selected evaporator coil for stable air distribution. Across the package, standard electrical requirements and conventional 24V controls support straightforward replacement and service workflows.

Summary Wrap-Up

As a complete ducted split system, this package pairs a 3 ton R-32 condenser with a 80% AFUE GR9T800603BX two-stage gas furnace and a TXV-metered CHPTA3630B3 evaporator coil to provide cooling and gas heat in one matched architecture. The outdoor condenser performs the refrigeration work, while the indoor coil provides the evaporator heat transfer surface and the furnace supplies airflow and combustion heat. Cabinet widths are selected so the furnace and coil align for practical installation and stable air distribution across the coil face. For contractors, commissioning focuses on blower airflow setup, refrigerant charge verification, venting and condensate completion where applicable, and verification of ignition and safety operation. For wholesale and D2C buyers, the value is a defined Goodman equipment set that uses serviceable components and conventional split-system architecture. Select this configuration when you need ducted central cooling with staged gas heat and clear component roles across the refrigeration and combustion sections.

Key Features

  • R-32 split-system architecture: One outdoor condenser and one indoor evaporator coil form a ducted refrigeration circuit using R-32 refrigerant.
  • Single-stage cooling operation: Outdoor section cycles to thermostat demand to deliver nominal 3 ton capacity with conventional non-communicating controls.
  • Two-stage gas heat section: GR9T800603BX furnace operates in low and high fire from 42,000 to 60,000 BTU/h input to track load.
  • ECM indoor airflow management: Multi-speed blower supports airflow tuning for cooling, heating, and continuous circulation, with up to 1,200 CFM capability depending on model.
  • TXV-metered evaporator coil: CHPTA3630B3 coil includes a factory-installed TXV for controlled refrigerant metering and stable evaporator operation.
  • Mounting and orientation flexibility: Furnace supports upflow or horizontal left/right installation, and the coil supports horizontal mounting to match duct routing.
  • Service and protection devices: Filter drier, accessible service valves, and refrigeration safeties support commissioning, diagnostics, and circuit protection.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
30.00 (in)
Height:
39.50 (in)
Depth:
29.00 (in)
Weight:
331.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Capacity (Tons):
3
EER:
12
Configuration:
Horizontal
Product Category:
Gas Heating & Air Conditioner Bundle
AHRI Certified:
Yes
Blower Motor Type:
ECM Constant Torque
Airflow (CFM):
1,200
AFUE:
80%
AHRI Reference Number:
214859758
Electrical Frequency:
60 Hz
Electrical Phase:
1-Phase
EER2:
12 EER2
Heating Input (BTU):
40,000 - 69,000 BTU
Cabinet Width (in):
17.5
Heating Stages:
Two Stage
Color:
Gray
Refrigerant Type:
R-32
Unit Weight:
316 lb
Vent Type:
Chimney / Category I
Shipping Weight:
346 lb
SEER2:
15 SEER2
Line Set Connection Type:
Braze
Prop 65 Warning:
Yes
Liquid Line Size:
3/8 in
Cooling Capacity (BTU):
36,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS4BA3610 - Nominal Capacity (Tons):
3
Condenser GLXS4BA3610 - Cooling Capacity (BTU/h):
36,000
Condenser GLXS4BA3610 - Refrigerant:
R-32
Condenser GLXS4BA3610 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS4BA3610 - Minimum Circuit Ampacity (MCA):
17.8 A
Condenser GLXS4BA3610 - Maximum Overcurrent Protection (MOP):
30 A
Condenser GLXS4BA3610 - Compressor Type:
Scroll
Condenser GLXS4BA3610 - Compressor Stages:
Single Stage
Condenser GLXS4BA3610 - Liquid Line Size:
3/8 in
Condenser GLXS4BA3610 - Suction Line Size:
7/8 in
Condenser GLXS4BA3610 - Sound Level (dB):
67
Condenser GLXS4BA3610 - Unit Dimensions (W x D x H):
29 in x 29 in x 39.5 in
Condenser GLXS4BA3610 - Unit Weight:
158 lb
Condenser GLXS4BA3610 - Shipping Weight:
173 lb
Furnace GR9T800603BX - Input (BTU/h):
60,000
Furnace GR9T800603BX - Output (BTU/h):
48,000
Furnace GR9T800603BX - AFUE:
80%
Furnace GR9T800603BX - Heating Stages:
Two Stage
Furnace GR9T800603BX - Blower Motor Type:
ECM Constant Torque
Furnace GR9T800603BX - Maximum Cooling Capacity (Tons):
3
Furnace GR9T800603BX - Configuration:
Upflow/Horizontal
Furnace GR9T800603BX - Cabinet Width:
17.5 in
Furnace GR9T800603BX - Vent Type:
Chimney / Category I
Furnace GR9T800603BX - Gas Type:
Propane Convertible
Furnace GR9T800603BX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GR9T800603BX - Unit Dimensions (W x D x H):
17.5 in x 28 in x 33.375 in
Furnace GR9T800603BX - Shipping Weight:
107 lb
Evaporator Coil CHPTA3630B3 - Nominal Capacity (Tons):
3
Evaporator Coil CHPTA3630B3 - Cased/Uncased:
Cased
Evaporator Coil CHPTA3630B3 - Configuration:
Horizontal
Evaporator Coil CHPTA3630B3 - Cabinet Width:
30 in
Evaporator Coil CHPTA3630B3 - Metering Device:
TXV
Evaporator Coil CHPTA3630B3 - Refrigerant:
R-32
Evaporator Coil CHPTA3630B3 - Liquid Line Size:
3/8 in
Evaporator Coil CHPTA3630B3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What size is the ?
The is a 3 ton unit.
What is the AFUE of the ?
The is rated at 80% AFUE.
Is the AHRI certified?
Yes. The AHRI reference number is 214859758.
What is the heating input of the ?
The heating input is 40,000 - 69,000 BTU BTU.
What refrigerant does the use?
It uses R-32 refrigerant.
What is the SEER2 rating of the ?
The is rated at 15 SEER2 SEER2.
How much cooling does the provide?
It is rated for 36,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS4BA3610-GR9T800603BX-CHPTA3630B3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS4BA3610-GR9T800603BX-CHPTA3630B3?
The GLXS4BA3610-GR9T800603BX-CHPTA3630B3 is made by Goodman.