Description
The Goodman 4 Ton 14 SEER2 96% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow with R-32 Refrigerant (GLXS4BA4810-GR9T961005CN-CAPTA6030C3) is a matched residential HVAC system designed to deliver reliable cooling and high-efficiency gas heating for year-round indoor comfort. This configuration combines the GLXS4BA4810 air conditioner condenser, GR9T961005CN high-efficiency gas furnace, and CAPTA6030C3 cased evaporator coil for an upflow residential installation.
With a nominal 4 ton / 48,000 BTU cooling capacity, 14 SEER2 cooling efficiency, and a 100,000 BTU furnace rated at 96% AFUE, this Goodman system provides a strong balance of cooling performance and efficient gas heating. The cooling circuit uses R-32 lower-GWP refrigerant, while the two-stage furnace helps provide more consistent heating comfort than conventional single-stage operation.
Key Features
- 4 Ton Cooling Capacity – Provides approximately 48,000 BTU of nominal cooling capacity
- 14 SEER2 Efficiency – Designed for efficient seasonal cooling performance in this matched configuration
- 100,000 BTU Gas Furnace – Provides substantial heating capacity for residential applications
- 96% AFUE Rating – High-efficiency furnace helps convert approximately 96% of fuel energy into usable heat
- Two-Stage Gas Furnace – GR9T series furnace supports staged heating for improved comfort control
- R-32 Refrigerant – Cooling circuit uses modern lower-GWP R-32 refrigerant
- Upflow Configuration – Designed for installations where conditioned air is distributed upward into the ductwork
- Gas Electric Operation – Combines electric air conditioning with natural gas furnace heating
Benefits
- Provides both air conditioning and gas heating in one matched HVAC configuration
- 4-ton capacity supports larger residential cooling requirements
- 96% AFUE furnace offers high-efficiency gas heating
- Two-stage heating helps maintain more consistent indoor temperatures
- 100,000 BTU furnace provides substantial heating capacity
- Uses lower-GWP R-32 refrigerant in the cooling circuit
- Upflow configuration supports many common residential duct layouts
- Matched Goodman components simplify HVAC equipment selection
- Suitable for new installations and compatible replacement applications
- Designed for dependable year-round indoor comfort
Compatibility & Installation
The Goodman GLXS4BA4810-GR9T961005CN-CAPTA6030C3 package includes the outdoor air conditioner, gas furnace, and cased evaporator coil required for the primary equipment portion of an upflow gas/electric split system. Proper sizing, airflow setup, refrigerant installation, and commissioning are essential for achieving the listed system performance.
Installation considerations:
- Verify 4-ton cooling capacity with a professional residential load calculation
- Confirm the 100,000 BTU furnace matches the home's heating requirements
- Ensure the installation requires an upflow airflow configuration
- Verify proper duct sizing and airflow requirements
- Provide appropriate gas supply and combustion air
- Follow required venting guidelines for the 96% AFUE condensing furnace
- Provide proper furnace and evaporator coil condensate drainage
- Follow R-32 A2L refrigerant handling and safety requirements
- Verify electrical requirements and equipment clearances
- Follow Goodman installation instructions and applicable local codes
- Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What cooling capacity does this Goodman system provide?
The system has a nominal 4-ton cooling capacity, equivalent to approximately 48,000 BTU.
What is the cooling efficiency rating?
This matched configuration is listed at 14 SEER2 cooling efficiency.
What is the furnace capacity and efficiency?
The GR9T961005CN furnace provides 100,000 BTU input capacity and is rated at 96% AFUE.
Is the furnace single-stage or two-stage?
The GR9T961005CN is a two-stage gas furnace, allowing staged heating operation for improved comfort control.
What refrigerant does this system use?
The air-conditioning circuit uses R-32, a lower-GWP A2L refrigerant used in newer HVAC systems.
What installation orientation is this system designed for?
This package is configured for an upflow installation, where conditioned air moves upward into the supply ductwork.
White Paper
- Goodman GLXS4B Spec Sheet
- Goodman GLXS Split AC Installation Manual
- Goodman GR9T96/GD9T96 Spec Sheet
- Goodman Evaporator Coil Spec Sheet
- Goodman CAPTA/CAPFA Coil Installation Manual
- Goodman GLXS4BA Repair Parts List (RP-G4341A)
- Goodman GR9T Repair Parts List – Rev AA/AB (RP-G2360A)
- Goodman CAPTA Repair Parts List (RP-4359A)
