Description
Product Summary
The Larkin LEL0125AY6AMAG0212 is a 12,500 BTU/h nominal low profile walk-in unit cooler from the Larkin LEL series by Heatcraft Refrigeration Products. It is a air defrost model with 2-speed ec motors and a 6 FPI coil, built for walk-in coolers held at 34°F and above.
Published ratings for this size include 15,500 BTU/h on R-448A at 10°F TD / 25°F SST and 15,700 BTU/h on R-454A. The unit runs on 115V 1-Phase power, moves 1,220 CFM through 2 fans.
This A2L/HFC (Y) version is rated for low-GWP A2L refrigerants R-454A, R-454C and R-455A as well as common HFC blends. It ships with the G0212 package: A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A.
Key Features
- Low Profile Cabinet: about 16-7/16 in. tall housing saves headroom in low-ceiling walk-in boxes
- 2-Speed EC Motor: electronically commutated fan motors cut fan energy versus PSC motors and can run at reduced speed when the system is satisfied
- Air Defrost: off-cycle air defrost for rooms above freezing
- Multi-Refrigerant Ratings: published capacities for R-404A, R-448A, R-449A, R-454A, R-454C, R-455A
- 6 FPI Coil: fin spacing sized for frost-tolerant walk-in operation
- DOE AWEF Compliant Platform: part of the Larkin low profile line documented as meeting DOE minimum AWEF requirements
- RDS and intelliGen Controller: A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A
Ideal Applications
- Walk-in coolers for restaurants and commercial kitchens
- Convenience store and grocery walk-ins
- Floral, produce and beverage coolers
- School, hospital and institutional food storage
Frequently Asked Questions
What refrigerants can the Larkin LEL0125AY6AMAG0212 use?
It is rated for R-404A, R-448A, R-449A, R-454A, R-454C, R-455A. Confirm the refrigerant matches your condensing unit and expansion valve before installation.
Is the LEL0125AY6AMAG0212 for a cooler or a freezer?
It is an air defrost unit for medium temperature coolers (room temperature above freezing).
What power supply does it need?
The unit is wired for 115V 1-Phase 60 Hz.
What condensing unit should I pair with it?
Match the condensing unit capacity to the evaporator capacity at your design suction temperature, such as a Larkin LCH medium temperature condensing unit. HVAC365 can help you size a matched system.
What does the option package include?
Package G0212 is the A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A.
White Paper