Larkin 17,000 BTU/h Low Profile Unit Cooler, 1-Speed EC Motors, Electric Defrost, A2L Ready, RDS and intelliGen Controller, 208/230V 1-Phase | LEL0170BY6EEAG0212

Larkin

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
LEL0170BY6EEAG0212
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
77.50 (in)
Height:
16.44 (in)
Depth:
13.25 (in)

Questions about Larkin 17,000 BTU/h Low Profile Unit Cooler, 1-Speed EC Motors, Electric Defrost, A2L Ready, RDS and intelliGen Controller, 208/230V 1-Phase | LEL0170BY6EEAG0212?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$8,800.40

10 in stock • Ships in 1-2 Weeks
Overview

Larkin 17,000 BTU/h Low Profile Unit Cooler, 1-Speed EC Motors, Electric Defrost, A2L Ready, RDS and intelliGen Controller, 208/230V 1-Phase | LEL0170BY6EEAG0212

Larkin LEL0170BY6EEAG0212 low profile walk-in unit cooler
Product details

Description

Product Summary

The Larkin LEL0170BY6EEAG0212 is a 17,000 BTU/h nominal low profile walk-in unit cooler from the Larkin LEL series by Heatcraft Refrigeration Products. It is a electric defrost model with 1-speed ec motors and a 6 FPI coil, built for walk-in freezers, with dual ratings that also allow cooler use.

Published ratings for this size include 17,900 BTU/h on R-448A at 10°F TD / -20°F SST and 17,400 BTU/h on R-454A. The unit runs on 208/230V 1-Phase power, moves 2,741 CFM through 4 fans.

This A2L/HFC (Y) version is rated for low-GWP A2L refrigerants R-454A, R-454C and R-455A as well as common HFC blends. It ships with the G0212 package: A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A.

Key Features

  • Low Profile Cabinet: about 16-7/16 in. tall housing saves headroom in low-ceiling walk-in boxes
  • 1-Speed EC Motor: electronically commutated fan motors cut fan energy versus PSC motors
  • Electric Defrost: factory electric defrost heaters (4,200 W) for freezer duty
  • Multi-Refrigerant Ratings: published capacities for R-404A, R-448A, R-449A, R-454A, R-454C, R-455A
  • 6 FPI Coil: fin spacing sized for frost-tolerant walk-in operation
  • DOE AWEF Compliant Platform: part of the Larkin low profile line documented as meeting DOE minimum AWEF requirements
  • RDS and intelliGen Controller: A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A

Ideal Applications

  • Walk-in freezers for restaurants and commercial kitchens
  • Convenience store and grocery freezers
  • Ice cream and frozen food storage
  • School, hospital and institutional frozen storage

Frequently Asked Questions

What refrigerants can the Larkin LEL0170BY6EEAG0212 use?

It is rated for R-404A, R-448A, R-449A, R-454A, R-454C, R-455A. Confirm the refrigerant matches your condensing unit and expansion valve before installation.

Is the LEL0170BY6EEAG0212 for a cooler or a freezer?

It is an electric defrost unit intended for freezers and is dual rated, so it can also be applied to coolers.

What power supply does it need?

The unit is wired for 208/230V 1-Phase 60 Hz. Electric defrost heaters draw significant current, so size the circuit per the nameplate.

What condensing unit should I pair with it?

Match the condensing unit capacity to the evaporator capacity at your design suction temperature, such as a Larkin LCH low temperature condensing unit. HVAC365 can help you size a matched system.

What does the option package include?

Package G0212 is the A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Larkin
Width:
77.50 (in)
Height:
16.44 (in)
Depth:
13.25 (in)
Weight:
91.00 LBS
Capacity (BTU/h):
10,000 - 19,999 BTU/h
Defrost Type:
Electric Defrost
Motor Type:
ECM (Electronically Commutated Motor)
Voltage / Phase:
208/230V 1-Phase
A2L Ready:
Yes
Model Number:
LEL0170BY6EEAG0212
Nominal Capacity:
17,000 BTU/h (model code)
Capacity R-404A (10°F TD / -20°F SST):
16,000 BTU/h
Capacity R-448A/R-449A (10°F TD / -20°F SST):
17,900 BTU/h
Capacity R-454A (10°F TD / -20°F SST):
17,400 BTU/h
Capacity R-454C (10°F TD / -20°F SST):
14,900 BTU/h
Capacity R-455A (10°F TD / -20°F SST):
17,000 BTU/h
Application:
Freezer (low temperature), dual rated for cooler use
Fan Motors:
EC 1-Speed
Number of Fans:
4
Airflow (CFM):
2,741 CFM
Fins Per Inch:
6
Fan Motor HP (each):
1/20
Defrost Heaters:
4,200 W (18.3 A at 208/230V 1-phase)
Coil Inlet Connection:
1/2 in. OD
Suction Connection:
7/8 in. OD
Drain Connection:
3/4 MPT in.
Dimensions (L x D x H):
77-1/2 x 13-1/4 x 16-7/16 in.
Net Weight (est.):
91 lb
Refrigerant Type:
R-404A, R-448A, R-449A, R-454A, R-454C, R-455A (A2L/HFC rated)
Factory Option Package:
G0212: A2L preferred package: refrigerant detection system (RDS) plus intelliGen controller, set up for R-454A
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
1 Year Parts | Registration Required within 60 Days of Purchase
Videos2 videos
Introducing the 2020 Heatcraft Low Profile Models!
Frequently asked questions
What power supply does the need?
It requires 208/230V 1-Phase power.
What refrigerant does the use?
It uses R-404A, R-448A, R-449A, R-454A, R-454C, R-455A (A2L/HFC rated) refrigerant.
What warranty comes with the LEL0170BY6EEAG0212?
1 Year Parts | Registration Required within 60 Days of Purchase
Who makes the LEL0170BY6EEAG0212?
The LEL0170BY6EEAG0212 is made by Larkin.