Kramer 1/2 HP Walk-In Cooler Refrigeration System for 6' x 8' Box, R-448A, 208/230V 1-Phase | KFO060M4SDA KL6A066ADASC

Kramer

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
KFO060M4SDA-KL6A066ADASC-6X8
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
27.88 (in)
Height:
35.50 (in)
Depth:
28.25 (in)

Questions about Kramer 1/2 HP Walk-In Cooler Refrigeration System for 6' x 8' Box, R-448A, 208/230V 1-Phase | KFO060M4SDA KL6A066ADASC?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$7,721.25

  • Qualifies for FREE Shipping
1 in stock • Ships in 3-5 Business Days
Overview

Kramer 1/2 HP Walk-In Cooler Refrigeration System for 6' x 8' Box, R-448A, 208/230V 1-Phase | KFO060M4SDA KL6A066ADASC

Kramer walk-in cooler refrigeration system for a 6' x 8' box: KFO060M4SDA condensing unit and KL6A066ADASC unit cooler
Product details

Description

Product Summary

This Kramer walk-in cooler refrigeration system pairs the Next-Gen KFO060M4SDA 1/2 HP medium temperature scroll condensing unit with the Kramer KL6A066ADASC low profile unit cooler. It is sized for a 6' x 8' walk-in cooler with an 8 ft ceiling held at 35°F, a common setup for restaurants, convenience stores, florists and small grocers.

Both halves are Kramer, and the match is built from Kramer's own published ratings. A 6' x 8' x 8' cooler at 35°F carries a standard box load of 5,884 BTU/h. Kramer's condensing unit catalog rates the KFO060M4SDA at 6,580 BTU/h on R-448A with 95°F outdoor air and a +25°F suction temperature, about 12% above the box load, and Kramer's unit cooler catalog rates the KL6A066ADASC at 7,800 BTU/h on R-448A at a 10°F coil temperature difference. Both catalogs are linked below so you or your contractor can check the numbers.

The Next-Gen condensing unit is Kramer's compact outdoor line for small and medium walk-ins, built around a Copeland ZB06KAE scroll compressor on 208/230V 1-phase power, and rated for R-448A, R-449A and R-404A.

The Kramer low profile unit cooler mounts to the ceiling of the box, runs on 115V with an EC 2-speed fan motor, and uses air defrost, the normal choice for a cooler held above freezing. It ships with the R-448A/R-449A expansion valve, liquid line solenoid valve and electronic thermostat already mounted, so there are fewer loose parts on the job.

Key Features

  • All Kramer system: condensing unit and unit cooler from the same manufacturer, sized from Kramer's published R-448A ratings.
  • Copeland scroll compressor: the ZB06KAE scroll delivers 6,580 BTU/h at 95°F outdoor air against a 5,884 BTU/h box load.
  • Factory-mounted valves and thermostat: the expansion valve, solenoid valve and electronic thermostat arrive mounted on the unit cooler.
  • Low profile EC fan coil: a slim ceiling-mounted coil with EC 2-speed motors saves headroom and power inside the box.

Frequently Asked Questions

What size walk-in cooler is this system for?

It is sized for a 6' x 8' walk-in cooler with an 8 ft ceiling held at 35°F under a standard load of 5,884 BTU/h. A box with heavy door traffic, warm product loading or glass doors can need more capacity, so call us at 1.888.509.3391 before ordering if your box is different.

How were these two units matched?

We sized the condensing unit and unit cooler from Kramer's own published capacity tables on R-448A at 95°F outdoor air, and both units cover the box load. Walk-in refrigeration does not use AHRI matched-system numbers like home air conditioners; each unit is rated on its own, and the Kramer catalogs behind this match are linked in the documents below.

How is the box temperature controlled?

The electronic thermostat opens and closes the liquid line solenoid valve. When the box reaches temperature, the solenoid closes, the system pumps down and the compressor shuts off on its low pressure control. When the box warms up, the solenoid opens and the compressor restarts, while the expansion valve meters refrigerant into the coil.

Does this system need a licensed installer?

Yes. A split refrigeration system needs refrigerant piping, evacuation, charging and electrical work, so it should be installed by a licensed refrigeration technician following Kramer's installation instructions.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Kramer
Width:
27.88 (in)
Height:
35.50 (in)
Depth:
28.25 (in)
Weight:
242.00 LBS
Product Category:
Walk-In Cooler Refrigeration System
System Type:
Split Condensing Unit + Unit Cooler
Box Size:
6' x 8' x 8' (W x L x H)
Application:
Walk-In Cooler (Medium Temp)
Room Temperature:
35°F
Estimated Box Load:
5,884 BTU/h (standard load)
Matched By:
Engineered match from Kramer published capacity data (R-448A)
Selection Conditions:
95°F ambient, +25°F SST, 10°F TD
Refrigerant (as selected):
R-448A
Refrigerant Type:
R-448A / R-449A
Condensing Unit Capacity at Selection:
6,580 BTU/h
Unit Cooler Capacity at Selection:
7,800 BTU/h
Defrost Type:
Air Defrost
Voltage / Phase:
208/230V 1-Phase
Unit Cooler Voltage:
115V 1-Phase
Brand:
Kramer
Model Number:
KFO060M4SDA KL6A066ADASC
Outdoor Unit KFO060M4SDA - Voltage / Phase:
208/230V 1-Phase
Outdoor Unit KFO060M4SDA - Model Number:
KFO060M4SDA
Outdoor Unit KFO060M4SDA - Product Line:
Next-Gen MiniCon (K-Series)
Outdoor Unit KFO060M4SDA - Product Category:
Condensing Unit
Outdoor Unit KFO060M4SDA - Horsepower (HP):
1/2 HP
Outdoor Unit KFO060M4SDA - Temperature Application:
Medium Temp
Outdoor Unit KFO060M4SDA - Compressor Type:
Scroll
Outdoor Unit KFO060M4SDA - Condenser Type:
Air-Cooled
Outdoor Unit KFO060M4SDA - Installation:
Indoor/Outdoor
Outdoor Unit KFO060M4SDA - Refrigeration Capacity:
6,830 BTU/h (+25°F SST, 90°F ambient, R-448A)
Outdoor Unit KFO060M4SDA - Capacity, R-404A:
7,350 BTU/h (+25°F SST, 90°F ambient)
Outdoor Unit KFO060M4SDA - Refrigerant Type:
R-448A, R-449A, R-404A
Outdoor Unit KFO060M4SDA - MCA / MOP:
15 A / 15 A
Outdoor Unit KFO060M4SDA - Compressor Model:
ZB06KAE
Outdoor Unit KFO060M4SDA - Capacity, R-448A (95°F Ambient / +25°F SST):
6,580 BTU/h
Indoor Unit KL6A066ADASC - Capacity (BTU/h):
5,000 - 9,999 BTU/h
Indoor Unit KL6A066ADASC - Defrost Type:
Air Defrost
Indoor Unit KL6A066ADASC - Motor Type:
ECM (Electronically Commutated Motor)
Indoor Unit KL6A066ADASC - Voltage / Phase:
115V 1-Phase
Indoor Unit KL6A066ADASC - Number of Fans:
1
Indoor Unit KL6A066ADASC - Refrigerant:
R-448A
Indoor Unit KL6A066ADASC - Model Number:
KL6A066ADASC
Indoor Unit KL6A066ADASC - Product Line:
Next-Gen All-Temp Low Profile
Indoor Unit KL6A066ADASC - Product Category:
Low Profile Unit Cooler
Indoor Unit KL6A066ADASC - Profile:
Low Profile
Indoor Unit KL6A066ADASC - Refrigeration Capacity:
6,600 BTU/h (25°F SST, 10°F TD, R-404A)
Indoor Unit KL6A066ADASC - Temperature Application:
Medium Temp
Indoor Unit KL6A066ADASC - Airflow (CFM):
775 CFM
Indoor Unit KL6A066ADASC - Fins Per Inch:
6
Indoor Unit KL6A066ADASC - Fan Motor:
EC 2-Speed
Indoor Unit KL6A066ADASC - Fan Motor Amps (115V EC):
0.8 A
Indoor Unit KL6A066ADASC - Liquid / Suction Connection:
3/8 in / 5/8 in
Indoor Unit KL6A066ADASC - Refrigerant Type:
R-448A, R-449A
Indoor Unit KL6A066ADASC - Factory Package:
factory-mounted R-448A/R-449A TXV, liquid line solenoid valve and electronic thermostat
Indoor Unit KL6A066ADASC - Shipping Weight:
47 lb
Indoor Unit KL6A066ADASC - Capacity, R-448A (10°F TD / +25°F SST):
7,800 BTU/h
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Frequently asked questions
What refrigerant does the use?
It uses R-448A / R-449A refrigerant.
What power supply does the need?
It requires 208/230V 1-Phase power.
Who makes the KFO060M4SDA-KL6A066ADASC-6X8?
The KFO060M4SDA-KL6A066ADASC-6X8 is made by Kramer.