Description
Rheem 2 Ton Air Conditioner Split System: RA15AY24AJ1NA + RF2TY2421STANSJB05417
This system pairs the Rheem RA15AY24AJ1NA air conditioner from the Endeavor Line Classic Series with the RF2TY2421STANSJB05417 air handler. It is an AHRI-matched combination (AHRI reference 215771389), which means the efficiency numbers below were certified for these two exact models working together. It provides central cooling, and the air handler can take an electric heat strip if you want electric heat from the same system.
Certified system performance
- AHRI reference number: 215771389
- Nominal capacity: 2 ton (24,000 BTU/h cooling)
- Cooling efficiency: 15.2 SEER2
- Refrigerant: R-454B
- Power supply: 208/230V 1-Phase
Outdoor unit: Rheem RA15AY24AJ1NA
The RA15AY24AJ1NA is an Endeavor Line Classic Series air conditioner with a single-stage compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.
- Nominal Capacity (Tons): 2
- Cooling Capacity (BTU/h): 22,800
- Refrigerant: R-454B
- Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
- Minimum Circuit Ampacity (MCA): 13 A
- Maximum Overcurrent Protection (MOP): 20 A
- Compressor Type: Scroll
- Compressor Stages: 1
- Liquid Line Size: 3/8 in
- Suction Line Size: 3/4 in
- Factory Refrigerant Charge: 112 oz
- Sound Level (dB): 69
- Unit Dimensions (W x D x H): 33.75 in x 33.75 in x 25 in
- Unit Weight: 178 lb
- Shipping Weight: 185 lb
Air handler: Rheem RF2TY2421STANSJB05417
The RF2TY2421STANSJB05417 is a matched Rheem air handler.
- Nominal Capacity (Tons): 2
- Airflow (CFM): 800
- Blower Motor Type: ECM (Electronically Commutated Motor), 1/3 HP
- Configuration: Vertical
- Metering Device: TXV/TEV - Thermostatic Expansion Valve
- Refrigerant: R-454B
- Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
- Unit Dimensions (W x D x H): 21.5 in x 17 in x 36 in
- Minimum Circuit Ampacity (MCA): 3 A (blower only, no electric heat)
- Unit Weight: 95 lb
- Shipping Weight: 105 lb
Electric heat
This air handler ships with a factory-installed 5 kW electric heater, so no separate heat strip is needed.
Sizing and installation
Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.
The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat, condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.
Common questions
Is this a matched system?
Yes. AHRI certificate 215771389 covers the RA15AY24AJ1NA with the RF2TY2421STANSJB05417.
Does it come with a heat strip?
Yes. The air handler has a factory-installed 5 kW heater.
Can I reuse my old refrigerant lines?
Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.