Rheem 4 Ton 19.0 SEER2 Air Conditioner Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RA19AY48AJVCA RHMVY4821SEACAJ

Rheem

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
RA19AY48AJVCA-RHMVY4821SEACAJ
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
662021725241
Condition:
New
Width:
36.10 (in)
Height:
51.20 (in)
Depth:
36.10 (in)

Questions about Rheem 4 Ton 19.0 SEER2 Air Conditioner Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RA19AY48AJVCA RHMVY4821SEACAJ?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$20,244.44

25 in stock • Ships in 2-3 Business Days
Overview

Rheem 4 Ton 19.0 SEER2 Air Conditioner Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RA19AY48AJVCA RHMVY4821SEACAJ

Rheem 4 Ton 19.0 SEER2 Air Conditioner Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B – RA19AY48AJVCA RHMVY4821SEACAJ – complete system
Product details

Description

Rheem 4 Ton Air Conditioner Split System: RA19AY48AJVCA + RHMVY4821SEACAJ

This system pairs the Rheem RA19AY48AJVCA air conditioner from the Endeavor Line Prestige Series with the RHMVY4821SEACAJ air handler. It is an AHRI-matched combination (AHRI reference 215737298), which means the efficiency numbers below were certified for these two exact models working together. It provides central cooling, and the air handler can take an electric heat strip if you want electric heat from the same system.

Certified system performance

  • AHRI reference number: 215737298
  • Nominal capacity: 4 ton (48,000 BTU/h cooling)
  • Cooling efficiency: 19.0 SEER2
  • Refrigerant: R-454B
  • Power supply: 208/230V 1-Phase

Outdoor unit: Rheem RA19AY48AJVCA

The RA19AY48AJVCA is an Endeavor Line Prestige Series air conditioner with a variable-speed inverter compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.

  • Nominal Capacity (Tons): 4
  • Cooling Capacity (BTU/h): 45,500
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 24 A
  • Maximum Overcurrent Protection (MOP): 40 A
  • Compressor Type: Scroll
  • Compressor Stages: Variable Speed (Inverter)
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Sound Level (dB): 54-72
  • Unit Dimensions (W x D x H): 36.13 in x 36.13 in x 51.17 in
  • Unit Weight: 255 lb
  • Shipping Weight: 263 lb

Air handler: Rheem RHMVY4821SEACAJ

The RHMVY4821SEACAJ is a matched Rheem air handler.

  • Nominal Capacity (Tons): 4
  • Airflow (CFM): 1,000-1,600
  • Configuration: Multi-Position
  • Metering Device: EEV - Electronic Expansion Valve
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Unit Dimensions (W x D x H): 21 in x 21.69 in x 57 in
  • Blower Motor Type: ECM Variable Speed
  • Minimum Circuit Ampacity (MCA): 8 A (blower only, no electric heat)
  • Unit Weight: 140 lb
  • Shipping Weight: 152 lb

Electric heat

No heat strip is included with this system. If you want auxiliary or emergency electric heat, choose one from the Add an Electric Heat Strip option above. These are the Rheem kits approved for this air handler: RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW).

Sizing and installation

Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.

The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat (this system requires the RETST800SYS control), condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.

Common questions

Is this a matched system?

Yes. AHRI certificate 215737298 covers the RA19AY48AJVCA with the RHMVY4821SEACAJ.

Does it come with a heat strip?

No. Heat strips are sold separately and can be added from the option above.

Can I reuse my old refrigerant lines?

Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Rheem
Width:
36.10 (in)
Height:
51.20 (in)
Depth:
36.10 (in)
Weight:
500.00 LBS
AHRI Certified:
Yes
AHRI Reference Number:
215737298
Refrigerant Type:
R-454B
Capacity (Tons):
4
Cooling Capacity (BTU):
48,000
SEER2:
19 SEER2
EER2:
12 EER2
Product Category:
Air Conditioner Split System
Product Line:
RA19AY
Outdoor Unit Model:
RA19AY48AJVCA
Air Handler Model:
RHMVY4821SEACAJ
Compatible Electric Heat Kits:
RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW)
Required Control (Sold Separately):
RETST800SYS
Electric Heat Options (kW):
4.8, 7.2, 9.6, 14.4, 17.0, 19.2, 24.0
UPC - RA19AY48AJVCA:
662021725241
UPC - RHMVY4821SEACAJ:
662021739811
Condenser RA19AY48AJVCA - Nominal Capacity (Tons):
4
Condenser RA19AY48AJVCA - Cooling Capacity (BTU/h):
45,500
Condenser RA19AY48AJVCA - Refrigerant:
R-454B
Condenser RA19AY48AJVCA - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser RA19AY48AJVCA - Minimum Circuit Ampacity (MCA):
24 A
Condenser RA19AY48AJVCA - Maximum Overcurrent Protection (MOP):
40 A
Condenser RA19AY48AJVCA - Compressor Type:
Scroll
Condenser RA19AY48AJVCA - Compressor Stages:
Variable Speed (Inverter)
Condenser RA19AY48AJVCA - Liquid Line Size:
3/8 in
Condenser RA19AY48AJVCA - Suction Line Size:
7/8 in
Condenser RA19AY48AJVCA - Sound Level (dB):
54-72
Condenser RA19AY48AJVCA - Unit Dimensions (W x D x H):
36.13 in x 36.13 in x 51.17 in
Condenser RA19AY48AJVCA - Unit Weight:
255 lb
Condenser RA19AY48AJVCA - Shipping Weight:
263 lb
Air Handler RHMVY4821SEACAJ - Nominal Capacity (Tons):
4
Air Handler RHMVY4821SEACAJ - Airflow (CFM):
1,000-1,600
Air Handler RHMVY4821SEACAJ - Configuration:
Multi-Position
Air Handler RHMVY4821SEACAJ - Metering Device:
EEV - Electronic Expansion Valve
Air Handler RHMVY4821SEACAJ - Refrigerant:
R-454B
Air Handler RHMVY4821SEACAJ - Voltage/Phase/Hz:
208-240 V / 1 Ph / 60 Hz
Air Handler RHMVY4821SEACAJ - Liquid Line Size:
3/8 in
Air Handler RHMVY4821SEACAJ - Suction Line Size:
7/8 in
Air Handler RHMVY4821SEACAJ - Unit Dimensions (W x D x H):
21 in x 21.69 in x 57 in
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
DOE Regional Compliance:
Nationwide
Compressor Stages:
Variable Speed
Discharge:
Top
Electrical Phase:
1-Phase
Energy Star Listed:
No
Matched Indoor Type:
Air Handler
Voltage / Phase:
208/230V 1-Phase
Air Handler RHMVY4821SEACAJ - Blower Motor Type:
ECM Variable Speed
Configuration:
Multi-Position
Blower Motor Type:
ECM Variable Speed
Air Handler RHMVY4821SEACAJ - Minimum Circuit Ampacity (MCA):
8 A (blower only, no electric heat)
Air Handler RHMVY4821SEACAJ - Unit Weight:
140 lb
Air Handler RHMVY4821SEACAJ - Shipping Weight:
152 lb
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos2 videos
Introducing the All-New Rheem® Endeavor® Line
Frequently asked questions
Is the AHRI certified?
Yes. The AHRI reference number is 215737298.
What refrigerant does the use?
It uses R-454B refrigerant.
What size is the ?
The is a 4 ton unit.
How much cooling does the provide?
It is rated for 48,000 BTU of cooling.
What is the SEER2 rating of the ?
The is rated at 19 SEER2 SEER2.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the RA19AY48AJVCA-RHMVY4821SEACAJ?
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the RA19AY48AJVCA-RHMVY4821SEACAJ?
The RA19AY48AJVCA-RHMVY4821SEACAJ is made by Rheem.