Rheem 2 Ton 19.0 SEER2 Heat Pump Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RD18AY24AJVCA RHMVY2417SEACNJ

Rheem

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
RD18AY24AJVCA-RHMVY2417SEACNJ
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
662021758836
Condition:
New
Width:
19.80 (in)
Height:
36.60 (in)
Depth:
40.40 (in)

Questions about Rheem 2 Ton 19.0 SEER2 Heat Pump Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RD18AY24AJVCA RHMVY2417SEACNJ?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$12,808.04

25 in stock • Ships in 2-3 Business Days
Overview

Rheem 2 Ton 19.0 SEER2 Heat Pump Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B | RD18AY24AJVCA RHMVY2417SEACNJ

Rheem 2 Ton 19.0 SEER2 Heat Pump Split System with Multi-Position Modulating ECM Variable Speed Air Handler R454B – RD18AY24AJVCA RHMVY2417SEACNJ – complete system
Product details

Description

Rheem 2 Ton Heat Pump Split System: RD18AY24AJVCA + RHMVY2417SEACNJ

This system pairs the Rheem RD18AY24AJVCA heat pump from the Endeavor Line Prestige Series with the RHMVY2417SEACNJ air handler. It is an AHRI-matched combination (AHRI reference 217176084), which means the efficiency numbers below were certified for these two exact models working together. As a heat pump, it cools in summer and moves heat into the home in winter, with electric heat strips available as backup for the coldest days.

Certified system performance

  • AHRI reference number: 217176084
  • Nominal capacity: 2 ton (24,000 BTU/h cooling)
  • Cooling efficiency: 19.0 SEER2
  • Refrigerant: R-454B
  • Power supply: 208/230V 1-Phase

Outdoor unit: Rheem RD18AY24AJVCA

The RD18AY24AJVCA is an Endeavor Line Prestige Series heat pump with a variable-speed inverter compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.

  • Nominal Capacity (Tons): 2
  • Cooling Capacity (BTU/h): 21,200
  • Heating Capacity (BTU/h): 21,200
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 19 A
  • Maximum Overcurrent Protection (MOP): 20 A
  • Compressor Type: Rotary
  • Compressor Stages: Variable Speed (Inverter)
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 3/4 in
  • Factory Refrigerant Charge: 76 oz
  • Sound Level (dB): 53-61
  • Unit Dimensions (W x D x H): 19.8 in x 40.4 in x 36.6 in
  • Unit Weight: 177 lb
  • Shipping Weight: 204 lb

Air handler: Rheem RHMVY2417SEACNJ

The RHMVY2417SEACNJ is a matched Rheem air handler.

  • Nominal Capacity (Tons): 2
  • Airflow (CFM): 500-800
  • Configuration: Multi-Position
  • Metering Device: EEV - Electronic Expansion Valve
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 3/4 in
  • Unit Dimensions (W x D x H): 17.5 in x 21.69 in x 42.5 in
  • Blower Motor Type: ECM Variable Speed
  • Minimum Circuit Ampacity (MCA): 4 A (blower only, no electric heat)
  • Unit Weight: 91 lb
  • Shipping Weight: 105 lb

Electric heat

No heat strip is included with this system. If you want auxiliary or emergency electric heat, choose one from the Add an Electric Heat Strip option above. These are the Rheem kits approved for this air handler: RXBH-1724A03J-B (3.0 kW), RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A13J-B (12.5 kW).

Sizing and installation

Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.

The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat (this system requires the RETST800SYS control), condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.

Common questions

Is this a matched system?

Yes. AHRI certificate 217176084 covers the RD18AY24AJVCA with the RHMVY2417SEACNJ.

Does it come with a heat strip?

No. Heat strips are sold separately and can be added from the option above.

Can I reuse my old refrigerant lines?

Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Rheem
Width:
19.80 (in)
Height:
36.60 (in)
Depth:
40.40 (in)
Weight:
500.00 LBS
AHRI Certified:
Yes
AHRI Reference Number:
217176084
Refrigerant Type:
R-454B
Capacity (Tons):
2
Cooling Capacity (BTU):
24,000
SEER2:
19 SEER2
EER2:
12 EER2
Product Category:
Heat Pump Split System
Product Line:
RD18AY
Outdoor Unit Model:
RD18AY24AJVCA
Air Handler Model:
RHMVY2417SEACNJ
Compatible Electric Heat Kits:
RXBH-1724A03J-B (3.0 kW), RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A13J-B (12.5 kW)
Required Control (Sold Separately):
RETST800SYS
HSPF2:
10+ HSPF2
Electric Heat Options (kW):
3.0, 4.8, 7.2, 9.6, 12.5
UPC - RD18AY24AJVCA:
662021758836
UPC - RHMVY2417SEACNJ:
662021708114
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
Heat Pump RD18AY24AJVCA - Nominal Capacity (Tons):
2
Heat Pump RD18AY24AJVCA - Cooling Capacity (BTU/h):
21,200
Heat Pump RD18AY24AJVCA - Heating Capacity (BTU/h):
21,200
Heat Pump RD18AY24AJVCA - Refrigerant:
R-454B
Heat Pump RD18AY24AJVCA - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump RD18AY24AJVCA - Minimum Circuit Ampacity (MCA):
19 A
Heat Pump RD18AY24AJVCA - Maximum Overcurrent Protection (MOP):
20 A
Heat Pump RD18AY24AJVCA - Compressor Type:
Rotary
Heat Pump RD18AY24AJVCA - Compressor Stages:
Variable Speed (Inverter)
Heat Pump RD18AY24AJVCA - Liquid Line Size:
3/8 in
Heat Pump RD18AY24AJVCA - Suction Line Size:
3/4 in
Heat Pump RD18AY24AJVCA - Factory Refrigerant Charge:
76 oz
Heat Pump RD18AY24AJVCA - Sound Level (dB):
53-61
Heat Pump RD18AY24AJVCA - Unit Dimensions (W x D x H):
19.8 in x 40.4 in x 36.6 in
Heat Pump RD18AY24AJVCA - Unit Weight:
177 lb
Heat Pump RD18AY24AJVCA - Shipping Weight:
204 lb
Air Handler RHMVY2417SEACNJ - Nominal Capacity (Tons):
2
Air Handler RHMVY2417SEACNJ - Airflow (CFM):
500-800
Air Handler RHMVY2417SEACNJ - Configuration:
Multi-Position
Air Handler RHMVY2417SEACNJ - Metering Device:
EEV - Electronic Expansion Valve
Air Handler RHMVY2417SEACNJ - Refrigerant:
R-454B
Air Handler RHMVY2417SEACNJ - Voltage/Phase/Hz:
208-240 V / 1 Ph / 60 Hz
Air Handler RHMVY2417SEACNJ - Liquid Line Size:
3/8 in
Air Handler RHMVY2417SEACNJ - Suction Line Size:
3/4 in
Air Handler RHMVY2417SEACNJ - Unit Dimensions (W x D x H):
17.5 in x 21.69 in x 42.5 in
DOE Regional Compliance:
Nationwide
Compressor Stages:
Variable Speed
Discharge:
Side
Electrical Phase:
1-Phase
Energy Star Listed:
Yes
Matched Indoor Type:
Air Handler
Voltage / Phase:
208/230V 1-Phase
Air Handler RHMVY2417SEACNJ - Blower Motor Type:
ECM Variable Speed
Configuration:
Multi-Position
Blower Motor Type:
ECM Variable Speed
Air Handler RHMVY2417SEACNJ - Minimum Circuit Ampacity (MCA):
4 A (blower only, no electric heat)
Air Handler RHMVY2417SEACNJ - Unit Weight:
91 lb
Air Handler RHMVY2417SEACNJ - Shipping Weight:
105 lb
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Frequently asked questions
Is the AHRI certified?
Yes. The AHRI reference number is 217176084.
What refrigerant does the use?
It uses R-454B refrigerant.
What size is the ?
The is a 2 ton unit.
How much cooling does the provide?
It is rated for 24,000 BTU of cooling.
What is the SEER2 rating of the ?
The is rated at 19 SEER2 SEER2.
What is the HSPF2 heating efficiency of the ?
It is rated at 10+ HSPF2 HSPF2.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the RD18AY24AJVCA-RHMVY2417SEACNJ?
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the RD18AY24AJVCA-RHMVY2417SEACNJ?
The RD18AY24AJVCA-RHMVY2417SEACNJ is made by Rheem.