Rheem 1.5 Ton 14.3 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | RP14AY18AJ1NA RH2VY2417STACNJ

Rheem

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
RP14AY18AJ1NA-RH2VY2417STACNJ
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
662021694776
Condition:
New
Width:
29.80 (in)
Height:
25.00 (in)
Depth:
29.80 (in)

Questions about Rheem 1.5 Ton 14.3 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | RP14AY18AJ1NA RH2VY2417STACNJ?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$8,511.31

25 in stock • Ships in 2-3 Business Days
Overview

Rheem 1.5 Ton 14.3 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | RP14AY18AJ1NA RH2VY2417STACNJ

Rheem 1.5 Ton 14.3 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B – RP14AY18AJ1NA RH2VY2417STACNJ – complete system
Product details

Description

Rheem 1.5 Ton Heat Pump Split System: RP14AY18AJ1NA + RH2VY2417STACNJ

This system pairs the Rheem RP14AY18AJ1NA heat pump from the Endeavor Line Classic Series with the RH2VY2417STACNJ air handler. It is an AHRI-matched combination (AHRI reference 216030780), which means the efficiency numbers below were certified for these two exact models working together. As a heat pump, it cools in summer and moves heat into the home in winter, with electric heat strips available as backup for the coldest days.

Certified system performance

  • AHRI reference number: 216030780
  • Nominal capacity: 1.5 ton (18,000 BTU/h cooling)
  • Cooling efficiency: 14.3 SEER2
  • Heating capacity: 16,600 BTU/h at 47°F
  • Refrigerant: R-454B
  • Power supply: 208/230V 1-Phase

Outdoor unit: Rheem RP14AY18AJ1NA

The RP14AY18AJ1NA is an Endeavor Line Classic Series heat pump with a single-stage compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.

  • Nominal Capacity (Tons): 1.5
  • Cooling Capacity (BTU/h): 17,100
  • Heating Capacity (BTU/h): 16,600
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 13 A
  • Maximum Overcurrent Protection (MOP): 20 A
  • Compressor Type: Scroll
  • Compressor Stages: 1
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 3/4 in
  • Factory Refrigerant Charge: 83 oz
  • Sound Level (dB): 73
  • Unit Dimensions (W x D x H): 29.75 in x 29.75 in x 25 in
  • Unit Weight: 153 lb
  • Shipping Weight: 160 lb

Air handler: Rheem RH2VY2417STACNJ

The RH2VY2417STACNJ is a matched Rheem air handler.

  • Nominal Capacity (Tons): 2
  • Airflow (CFM): 580-767
  • Blower Motor Type: ECM (Electronically Commutated Motor), 1/3 HP
  • Configuration: Convertible
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 4 A (blower only, no electric heat)
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 3/4 in
  • Unit Dimensions (W x D x H): 17.5 in x 21.69 in x 42.5 in
  • Unit Weight: 91 lb
  • Shipping Weight: 105 lb

Electric heat

No heat strip is included with this system. If you want auxiliary or emergency electric heat, choose one from the Add an Electric Heat Strip option above. These are the Rheem kits approved for this air handler: RXBH-1724A03J-B (3.0 kW), RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A13J-B (12.5 kW).

Sizing and installation

Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.

The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat, condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.

Common questions

Is this a matched system?

Yes. AHRI certificate 216030780 covers the RP14AY18AJ1NA with the RH2VY2417STACNJ.

Does it come with a heat strip?

No. Heat strips are sold separately and can be added from the option above.

Can I reuse my old refrigerant lines?

Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Rheem
Width:
29.80 (in)
Height:
25.00 (in)
Depth:
29.80 (in)
Weight:
500.00 LBS
AHRI Certified:
Yes
AHRI Reference Number:
216030780
Refrigerant Type:
R-454B
Capacity (Tons):
1.5
Cooling Capacity (BTU):
18,000
SEER2:
14 SEER2
EER2:
9 EER2
Product Category:
Heat Pump Split System
Product Line:
RP14AY
Outdoor Unit Model:
RP14AY18AJ1NA
Air Handler Model:
RH2VY2417STACNJ
Compatible Electric Heat Kits:
RXBH-1724A03J-B (3.0 kW), RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A13J-B (12.5 kW)
HSPF2:
7 HSPF2
Electric Heat Options (kW):
3.0, 4.8, 7.2, 9.6, 12.5
UPC - RP14AY18AJ1NA:
662021694776
UPC - RH2VY2417STACNJ:
662021713514
Heat Pump RP14AY18AJ1NA - Nominal Capacity (Tons):
1.5
Heat Pump RP14AY18AJ1NA - Cooling Capacity (BTU/h):
17,100
Heat Pump RP14AY18AJ1NA - Heating Capacity (BTU/h):
16,600
Heat Pump RP14AY18AJ1NA - Refrigerant:
R-454B
Heat Pump RP14AY18AJ1NA - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump RP14AY18AJ1NA - Minimum Circuit Ampacity (MCA):
13 A
Heat Pump RP14AY18AJ1NA - Maximum Overcurrent Protection (MOP):
20 A
Heat Pump RP14AY18AJ1NA - Compressor Type:
Scroll
Heat Pump RP14AY18AJ1NA - Compressor Stages:
1
Heat Pump RP14AY18AJ1NA - Liquid Line Size:
3/8 in
Heat Pump RP14AY18AJ1NA - Suction Line Size:
3/4 in
Heat Pump RP14AY18AJ1NA - Factory Refrigerant Charge:
83 oz
Heat Pump RP14AY18AJ1NA - Sound Level (dB):
73
Heat Pump RP14AY18AJ1NA - Unit Dimensions (W x D x H):
29.75 in x 29.75 in x 25 in
Heat Pump RP14AY18AJ1NA - Unit Weight:
153 lb
Heat Pump RP14AY18AJ1NA - Shipping Weight:
160 lb
Air Handler RH2VY2417STACNJ - Nominal Capacity (Tons):
2
Air Handler RH2VY2417STACNJ - Airflow (CFM):
580-767
Air Handler RH2VY2417STACNJ - Blower Motor Type:
ECM (Electronically Commutated Motor), 1/3 HP
Air Handler RH2VY2417STACNJ - Configuration:
Convertible
Air Handler RH2VY2417STACNJ - Metering Device:
TXV/TEV - Thermostatic Expansion Valve
Air Handler RH2VY2417STACNJ - Refrigerant:
R-454B
Air Handler RH2VY2417STACNJ - Voltage/Phase/Hz:
208-240 V / 1 Ph / 60 Hz
Air Handler RH2VY2417STACNJ - Minimum Circuit Ampacity (MCA):
4 A (blower only, no electric heat)
Air Handler RH2VY2417STACNJ - Liquid Line Size:
3/8 in
Air Handler RH2VY2417STACNJ - Suction Line Size:
3/4 in
Air Handler RH2VY2417STACNJ - Unit Dimensions (W x D x H):
17.5 in x 21.69 in x 42.5 in
Air Handler RH2VY2417STACNJ - Unit Weight:
91 lb
Air Handler RH2VY2417STACNJ - Shipping Weight:
105 lb
Prop 65 Warning:
Yes
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
DOE Regional Compliance:
Nationwide
Compressor Stages:
Single Stage
Discharge:
Top
Electrical Phase:
1-Phase
Energy Star Listed:
No
Matched Indoor Type:
Air Handler
Voltage / Phase:
208/230V 1-Phase
Configuration:
Multi-Position
Blower Motor Type:
ECM Variable Speed
Heating Output (BTU):
10,000 - 19,000 BTU
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos2 videos
Introducing the All-New Rheem® Endeavor® Line
Frequently asked questions
Is the AHRI certified?
Yes. The AHRI reference number is 216030780.
What refrigerant does the use?
It uses R-454B refrigerant.
What size is the ?
The is a 1.5 ton unit.
How much cooling does the provide?
It is rated for 18,000 BTU of cooling.
What is the SEER2 rating of the ?
The is rated at 14 SEER2 SEER2.
What is the HSPF2 heating efficiency of the ?
It is rated at 7 HSPF2 HSPF2.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the RP14AY18AJ1NA-RH2VY2417STACNJ?
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the RP14AY18AJ1NA-RH2VY2417STACNJ?
The RP14AY18AJ1NA-RH2VY2417STACNJ is made by Rheem.