Description
Rheem 3 Ton Heat Pump Split System: RP14AY36AJ2NA + RF2TY3624STANSJB05417
This system pairs the Rheem RP14AY36AJ2NA heat pump from the Endeavor Line Classic Series with the RF2TY3624STANSJB05417 air handler. It is an AHRI-matched combination (AHRI reference 215772231), which means the efficiency numbers below were certified for these two exact models working together. As a heat pump, it cools in summer and moves heat into the home in winter, with electric heat strips available as backup for the coldest days.
Certified system performance
- AHRI reference number: 215772231
- Nominal capacity: 3 ton (36,000 BTU/h cooling)
- Cooling efficiency: 14.3 SEER2
- Heating capacity: 33,600 BTU/h at 47°F
- Refrigerant: R-454B
- Power supply: 208/230V 1-Phase
Outdoor unit: Rheem RP14AY36AJ2NA
The RP14AY36AJ2NA is an Endeavor Line Classic Series heat pump with a two-stage compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.
- Nominal Capacity (Tons): 3
- Cooling Capacity (BTU/h): 34,200
- Heating Capacity (BTU/h): 33,600
- Refrigerant: R-454B
- Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
- Minimum Circuit Ampacity (MCA): 20 A
- Maximum Overcurrent Protection (MOP): 30 A
- Compressor Type: Scroll
- Compressor Stages: 2
- Liquid Line Size: 3/8 in
- Suction Line Size: 3/4 in
- Factory Refrigerant Charge: 94 oz
- Sound Level (dB): 72
- Unit Dimensions (W x D x H): 33.75 in x 33.75 in x 35 in
- Unit Weight: 202 lb
- Shipping Weight: 209 lb
Air handler: Rheem RF2TY3624STANSJB05417
The RF2TY3624STANSJB05417 is a matched Rheem air handler.
- Nominal Capacity (Tons): 3
- Airflow (CFM): 1,200
- Blower Motor Type: ECM (Electronically Commutated Motor), 1/2 HP
- Configuration: Vertical
- Metering Device: TXV/TEV - Thermostatic Expansion Valve
- Refrigerant: R-454B
- Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
- Unit Dimensions (W x D x H): 24.5 in x 21 in x 36 in
- Unit Weight: 95 lb
- Minimum Circuit Ampacity (MCA): 4 A (blower only, no electric heat)
- Shipping Weight: 105 lb
Electric heat
This air handler ships with a factory-installed 5 kW electric heater, so no separate heat strip is needed.
Sizing and installation
Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.
The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat, condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.
Common questions
Is this a matched system?
Yes. AHRI certificate 215772231 covers the RP14AY36AJ2NA with the RF2TY3624STANSJB05417.
Does it come with a heat strip?
Yes. The air handler has a factory-installed 5 kW heater.
Can I reuse my old refrigerant lines?
Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.
White Paper