Rheem Select Series 5 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Constant Torque Air Handler R454B | WP14AY60AJ2NA RH2TY6024STANNJ

Rheem

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
WP14AY60AJ2NA-RH2TY6024STANNJ
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
662021692406
Condition:
New
Width:
35.50 (in)
Height:
39.20 (in)
Depth:
35.50 (in)

Questions about Rheem Select Series 5 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Constant Torque Air Handler R454B | WP14AY60AJ2NA RH2TY6024STANNJ?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$8,248.20

25 in stock • Ships in 2-3 Business Days
Overview

Rheem Select Series 5 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Constant Torque Air Handler R454B | WP14AY60AJ2NA RH2TY6024STANNJ

Rheem Select Series 5 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Constant Torque Air Handler R454B – WP14AY60AJ2NA RH2TY6024STANNJ – complete system
Product details

Description

Rheem 5 Ton Heat Pump Split System: WP14AY60AJ2NA + RH2TY6024STANNJ

This system pairs the Rheem WP14AY60AJ2NA heat pump from the Endeavor Line Select Series with the RH2TY6024STANNJ air handler. It is an AHRI-matched combination (AHRI reference 214803219), which means the efficiency numbers below were certified for these two exact models working together. As a heat pump, it cools in summer and moves heat into the home in winter, with electric heat strips available as backup for the coldest days.

Certified system performance

  • AHRI reference number: 214803219
  • Nominal capacity: 5 ton (57,000 BTU/h cooling)
  • Cooling efficiency: 15.2 SEER2
  • Heating capacity: 55,000 BTU/h at 47°F
  • Refrigerant: R-454B
  • Power supply: 208/230V 1-Phase

Outdoor unit: Rheem WP14AY60AJ2NA

The WP14AY60AJ2NA is an Endeavor Line Select Series heat pump with a two-stage compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.

  • Nominal Capacity (Tons): 5
  • Cooling Capacity (BTU/h): 54,000
  • Heating Capacity (BTU/h): 54,000
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 33 A
  • Maximum Overcurrent Protection (MOP): 50 A
  • Compressor Type: Scroll
  • Compressor Stages: 2
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Factory Refrigerant Charge: 194 oz
  • Sound Level (dB): 74
  • Unit Dimensions (W x D x H): 35.54 in x 35.54 in x 39.17 in
  • Unit Weight: 253 lb
  • Shipping Weight: 303 lb

Air handler: Rheem RH2TY6024STANNJ

The RH2TY6024STANNJ is a matched Rheem air handler.

  • Nominal Capacity (Tons): 5
  • Airflow (CFM): 1,200-1,600
  • Blower Motor Type: ECM (Electronically Commutated Motor), 3/4 HP
  • Configuration: Multi-Position
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 6 A (blower only, no electric heat)
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Unit Dimensions (W x D x H): 24.5 in x 21.69 in x 55.5 in
  • Unit Weight: 161 lb
  • Shipping Weight: 178 lb

Electric heat

No heat strip is included with this system. If you want auxiliary or emergency electric heat, choose one from the Add an Electric Heat Strip option above. These are the Rheem kits approved for this air handler: RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW).

Sizing and installation

Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.

The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat, condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.

Common questions

Is this a matched system?

Yes. AHRI certificate 214803219 covers the WP14AY60AJ2NA with the RH2TY6024STANNJ.

Does it come with a heat strip?

No. Heat strips are sold separately and can be added from the option above.

Can I reuse my old refrigerant lines?

Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Rheem
Width:
35.50 (in)
Height:
39.20 (in)
Depth:
35.50 (in)
Weight:
500.00 LBS
AHRI Certified:
Yes
AHRI Reference Number:
214803219
Refrigerant Type:
R-454B
Capacity (Tons):
5
Cooling Capacity (BTU):
57,000
SEER2:
15 SEER2
EER2:
11 EER2
Product Category:
Heat Pump Split System
Product Line:
WP14AY
Outdoor Unit Model:
WP14AY60AJ2NA
Air Handler Model:
RH2TY6024STANNJ
Compatible Electric Heat Kits:
RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW)
HSPF2:
7 HSPF2
Electric Heat Options (kW):
4.8, 7.2, 9.6, 14.4, 17.0, 19.2, 24.0
UPC - WP14AY60AJ2NA:
662021692406
UPC - RH2TY6024STANNJ:
662021698392
Heat Pump WP14AY60AJ2NA - Nominal Capacity (Tons):
5
Heat Pump WP14AY60AJ2NA - Cooling Capacity (BTU/h):
54,000
Heat Pump WP14AY60AJ2NA - Heating Capacity (BTU/h):
54,000
Heat Pump WP14AY60AJ2NA - Refrigerant:
R-454B
Heat Pump WP14AY60AJ2NA - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump WP14AY60AJ2NA - Minimum Circuit Ampacity (MCA):
33 A
Heat Pump WP14AY60AJ2NA - Maximum Overcurrent Protection (MOP):
50 A
Heat Pump WP14AY60AJ2NA - Compressor Type:
Scroll
Heat Pump WP14AY60AJ2NA - Compressor Stages:
2
Heat Pump WP14AY60AJ2NA - Liquid Line Size:
3/8 in
Heat Pump WP14AY60AJ2NA - Suction Line Size:
7/8 in
Heat Pump WP14AY60AJ2NA - Factory Refrigerant Charge:
194 oz
Heat Pump WP14AY60AJ2NA - Sound Level (dB):
74
Heat Pump WP14AY60AJ2NA - Unit Dimensions (W x D x H):
35.54 in x 35.54 in x 39.17 in
Air Handler RH2TY6024STANNJ - Nominal Capacity (Tons):
5
Air Handler RH2TY6024STANNJ - Airflow (CFM):
1,200-1,600
Air Handler RH2TY6024STANNJ - Blower Motor Type:
ECM (Electronically Commutated Motor), 3/4 HP
Air Handler RH2TY6024STANNJ - Configuration:
Multi-Position
Air Handler RH2TY6024STANNJ - Metering Device:
TXV/TEV - Thermostatic Expansion Valve
Air Handler RH2TY6024STANNJ - Refrigerant:
R-454B
Air Handler RH2TY6024STANNJ - Voltage/Phase/Hz:
208-240 V / 1 Ph / 60 Hz
Air Handler RH2TY6024STANNJ - Minimum Circuit Ampacity (MCA):
6 A (blower only, no electric heat)
Air Handler RH2TY6024STANNJ - Liquid Line Size:
3/8 in
Air Handler RH2TY6024STANNJ - Suction Line Size:
7/8 in
Air Handler RH2TY6024STANNJ - Unit Dimensions (W x D x H):
24.5 in x 21.69 in x 55.5 in
Air Handler RH2TY6024STANNJ - Unit Weight:
161 lb
Air Handler RH2TY6024STANNJ - Shipping Weight:
178 lb
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
DOE Regional Compliance:
Nationwide
Compressor Stages:
Two Stage
Discharge:
Top
Electrical Phase:
1-Phase
Energy Star Listed:
Yes
Matched Indoor Type:
Air Handler
Voltage / Phase:
208/230V 1-Phase
Heat Pump WP14AY60AJ2NA - Unit Weight:
253 lb
Heat Pump WP14AY60AJ2NA - Shipping Weight:
303 lb
Configuration:
Multi-Position
Blower Motor Type:
ECM Constant Torque
Heating Output (BTU):
40,000 - 69,000 BTU
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos2 videos
Introducing the All-New Rheem® Endeavor® Line
Frequently asked questions
Is the AHRI certified?
Yes. The AHRI reference number is 214803219.
What refrigerant does the use?
It uses R-454B refrigerant.
What size is the ?
The is a 5 ton unit.
How much cooling does the provide?
It is rated for 57,000 BTU of cooling.
What is the SEER2 rating of the ?
The is rated at 15 SEER2 SEER2.
What is the HSPF2 heating efficiency of the ?
It is rated at 7 HSPF2 HSPF2.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the WP14AY60AJ2NA-RH2TY6024STANNJ?
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the WP14AY60AJ2NA-RH2TY6024STANNJ?
The WP14AY60AJ2NA-RH2TY6024STANNJ is made by Rheem.