Rheem Select Series 4 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | WP14AY48AJ2NA RH2VY4821STACNJ

Rheem

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
WP14AY48AJ2NA-RH2VY4821STACNJ
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
662021692161
Condition:
New
Width:
33.66 (in)
Height:
35.17 (in)
Depth:
33.66 (in)

Questions about Rheem Select Series 4 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | WP14AY48AJ2NA RH2VY4821STACNJ?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$10,497.69

15 in stock • Ships in 1-2 Business Days
Overview

Rheem Select Series 4 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B | WP14AY48AJ2NA RH2VY4821STACNJ

Rheem Select Series 4 Ton 15.2 SEER2 Heat Pump Split System with Multi-Position ECM Variable Speed Air Handler R454B – WP14AY48AJ2NA RH2VY4821STACNJ
Product details

Description

Rheem 4 Ton Heat Pump Split System: WP14AY48AJ2NA + RH2VY4821STACNJ

This system pairs the Rheem WP14AY48AJ2NA heat pump from the Endeavor Line Select Series with the RH2VY4821STACNJ air handler. It is an AHRI-matched combination (AHRI reference 216030788), which means the efficiency numbers below were certified for these two exact models working together. As a heat pump, it cools in summer and moves heat into the home in winter, with electric heat strips available as backup for the coldest days.

Certified system performance

  • AHRI reference number: 216030788
  • Nominal capacity: 4 ton (48,000 BTU/h cooling)
  • Cooling efficiency: 15.2 SEER2
  • Heating capacity: 48,000 BTU/h at 47°F
  • Refrigerant: R-454B
  • Power supply: 208/230V 1-Phase

Outdoor unit: Rheem WP14AY48AJ2NA

The WP14AY48AJ2NA is an Endeavor Line Select Series heat pump with a two-stage compressor. It runs on R-454B, the lower global-warming-potential refrigerant required in new U.S. residential systems.

  • Nominal Capacity (Tons): 4
  • Cooling Capacity (BTU/h): 48,000
  • Heating Capacity (BTU/h): 48,000
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-230 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 27 A
  • Maximum Overcurrent Protection (MOP): 45 A
  • Compressor Type: Scroll
  • Compressor Stages: 2
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Sound Level (dB): 74
  • Unit Dimensions (W x D x H): 33.66 in x 33.66 in x 35.17 in
  • Unit Weight: 220 lb
  • Shipping Weight: 259 lb

Air handler: Rheem RH2VY4821STACNJ

The RH2VY4821STACNJ is a matched Rheem air handler.

  • Nominal Capacity (Tons): 4
  • Airflow (CFM): 1,024-1,478
  • Blower Motor Type: ECM (Electronically Commutated Motor), 3/4 HP
  • Configuration: Convertible
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Refrigerant: R-454B
  • Voltage/Phase/Hz: 208-240 V / 1 Ph / 60 Hz
  • Minimum Circuit Ampacity (MCA): 7 A (blower only, no electric heat)
  • Liquid Line Size: 3/8 in
  • Suction Line Size: 7/8 in
  • Unit Dimensions (W x D x H): 21 in x 21.69 in x 50.5 in
  • Unit Weight: 128 lb
  • Shipping Weight: 144 lb
  • Cabinet Width: 21 in

Electric heat

No heat strip is included with this system. If you want auxiliary or emergency electric heat, choose one from the Add an Electric Heat Strip option above. These are the Rheem kits approved for this air handler: RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW).

Sizing and installation

Size the system from a room-by-room load calculation (ACCA Manual J) rather than square footage alone. Climate, insulation, windows and duct condition all change the load, and an oversized system short-cycles and leaves humidity behind.

The outdoor unit and air handler each need their own electrical circuit sized to the rating plate. The refrigerant line set, thermostat, condensate drain, pad and installation materials are sold separately. Because R-454B is a mildly flammable (A2L) refrigerant, installation and service require a licensed HVAC technician using A2L-rated tools and the manufacturer's procedures, which also keeps the warranty in force.

Common questions

Is this a matched system?

Yes. AHRI certificate 216030788 covers the WP14AY48AJ2NA with the RH2VY4821STACNJ.

Does it come with a heat strip?

No. Heat strips are sold separately and can be added from the option above.

Can I reuse my old refrigerant lines?

Sometimes. Line sizes must match the outdoor unit and the lines must be clean, leak-free and compatible with R-454B. Your installer should inspect them and flush or replace them as needed.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Rheem
Width:
33.66 (in)
Height:
35.17 (in)
Depth:
33.66 (in)
Weight:
500.00 LBS
Airflow (CFM):
1,600
Capacity (Tons):
4
Color:
Gray
Configuration:
Multi-Position
Product Category:
Heat Pump Split System
Electrical Phase:
1-Phase
Electrical Frequency:
60 Hz
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Cooling Capacity (BTU):
48,000
Heating Output (BTU):
40,000 - 69,000 BTU
AHRI Certified:
Yes
Refrigerant Type:
R-454B
Prop 65 Warning:
Yes
SEER2:
15 SEER2
AHRI Reference Number:
216030788
EER2:
10 EER2
HSPF2:
7 HSPF2
Product Line:
WP14AY
Outdoor Unit Model:
WP14AY48AJ2NA
Air Handler Model:
RH2VY4821STACNJ
Compatible Electric Heat Kits:
RXBH-1724A05J-B (4.8 kW), RXBH-1724A07J-B (7.2 kW), RXBH-1724A10J-B (9.6 kW), RXBH-1724A15J-B (14.4 kW), RXBH-1724A18J-B (17.0 kW), RXBH-24A20J-B (19.2 kW), RXBH-24A25J-B (24.0 kW)
Electric Heat Options (kW):
4.8, 7.2, 9.6, 14.4, 17.0, 19.2, 24.0
UPC - WP14AY48AJ2NA:
662021692161
UPC - RH2VY4821STACNJ:
662021713002
DOE Regional Compliance:
Nationwide
Compressor Stages:
Two Stage
Discharge:
Top
Energy Star Listed:
No
Matched Indoor Type:
Air Handler
Voltage / Phase:
208/230V 1-Phase
Heat Pump WP14AY48AJ2NA - Nominal Capacity (Tons):
4
Heat Pump WP14AY48AJ2NA - Cooling Capacity (BTU/h):
48,000
Heat Pump WP14AY48AJ2NA - Heating Capacity (BTU/h):
48,000
Heat Pump WP14AY48AJ2NA - Refrigerant:
R-454B
Heat Pump WP14AY48AJ2NA - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Heat Pump WP14AY48AJ2NA - Minimum Circuit Ampacity (MCA):
27 A
Heat Pump WP14AY48AJ2NA - Maximum Overcurrent Protection (MOP):
45 A
Heat Pump WP14AY48AJ2NA - Compressor Type:
Scroll
Heat Pump WP14AY48AJ2NA - Compressor Stages:
2
Heat Pump WP14AY48AJ2NA - Liquid Line Size:
3/8 in
Heat Pump WP14AY48AJ2NA - Suction Line Size:
7/8 in
Heat Pump WP14AY48AJ2NA - Sound Level (dB):
74
Heat Pump WP14AY48AJ2NA - Unit Dimensions (W x D x H):
33.66 in x 33.66 in x 35.17 in
Heat Pump WP14AY48AJ2NA - Unit Weight:
220 lb
Heat Pump WP14AY48AJ2NA - Shipping Weight:
259 lb
Air Handler RH2VY4821STACNJ - Nominal Capacity (Tons):
4
Air Handler RH2VY4821STACNJ - Airflow (CFM):
1,024-1,478
Air Handler RH2VY4821STACNJ - Blower Motor Type:
ECM (Electronically Commutated Motor), 3/4 HP
Air Handler RH2VY4821STACNJ - Configuration:
Convertible
Air Handler RH2VY4821STACNJ - Metering Device:
TXV/TEV - Thermostatic Expansion Valve
Air Handler RH2VY4821STACNJ - Refrigerant:
R-454B
Air Handler RH2VY4821STACNJ - Voltage/Phase/Hz:
208-240 V / 1 Ph / 60 Hz
Air Handler RH2VY4821STACNJ - Minimum Circuit Ampacity (MCA):
7 A (blower only, no electric heat)
Air Handler RH2VY4821STACNJ - Liquid Line Size:
3/8 in
Air Handler RH2VY4821STACNJ - Suction Line Size:
7/8 in
Air Handler RH2VY4821STACNJ - Unit Dimensions (W x D x H):
21 in x 21.69 in x 50.5 in
Air Handler RH2VY4821STACNJ - Unit Weight:
128 lb
Air Handler RH2VY4821STACNJ - Shipping Weight:
144 lb
Air Handler RH2VY4821STACNJ - Cabinet Width:
21 in
Blower Motor Type:
ECM Variable Speed
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos1 videos
The History of Rheem Air Conditioning & Heating
Frequently asked questions
What size is the ?
The is a 4 ton unit.
How much cooling does the provide?
It is rated for 48,000 BTU of cooling.
What refrigerant does the use?
It uses R-454B refrigerant.
What is the SEER2 rating of the ?
The is rated at 15 SEER2 SEER2.
Is the AHRI certified?
Yes. The AHRI reference number is 216030788.
What is the HSPF2 heating efficiency of the ?
It is rated at 7 HSPF2 HSPF2.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the WP14AY48AJ2NA-RH2VY4821STACNJ?
10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the WP14AY48AJ2NA-RH2VY4821STACNJ?
The WP14AY48AJ2NA-RH2VY4821STACNJ is made by Rheem.