Coldflow 20 Ton Horizontal Geothermal Water Source Heat Pump Right Return with R454B Refrigerant 460V 3-Phase | CFF240D4-HREFN-X

Coldflow

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
CFF240D4-HREFN-X-RMD
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
93.25 (in)
Height:
31.00 (in)
Depth:
36.00 (in)

Questions about Coldflow 20 Ton Horizontal Geothermal Water Source Heat Pump Right Return with R454B Refrigerant 460V 3-Phase | CFF240D4-HREFN-X?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$28,259.72

  • Qualifies for FREE Shipping
5 in stock • Ships in 3-5 Business Days
Overview

Coldflow 20 Ton Horizontal Geothermal Water Source Heat Pump Right Return with R454B Refrigerant 460V 3-Phase | CFF240D4-HREFN-X

Coldflow CFF240H-RF-D 20 Ton Horizontal Water Source Heat Pump Right Return
Product details

Description

The Coldflow CFF240D4-HREFN-X is a 20-ton horizontal water source heat pump from Coldflow's CFF series, built in Miami, Florida. It is a self-contained water-to-air unit that heats and cools by exchanging heat with a water loop, a well (ground water) or a closed ground loop, so it works on boiler/tower loop systems as well as geothermal installations. This model has a right-hand return, runs on 460V three-phase, 60 Hz power and uses low-GWP R-454B refrigerant.

Coldflow builds the CFF series for long service life in demanding environments: a stainless steel cabinet and insulated stainless steel drain pan, a coaxial cupronickel water-to-refrigerant heat exchanger, and a high-efficiency scroll compressor with internal thermal overload protection. It is a strong fit for commercial buildings, multifamily mechanical rooms, schools, offices and light industrial spaces where you want quiet, efficient zone comfort without an outdoor condensing unit.

Key Features

  • Stainless steel construction: Stainless steel cabinet and insulated stainless steel drain pan resist corrosion in mechanical rooms, closets and other humid spaces.
  • Cupronickel coaxial heat exchanger: Coaxial cupronickel water coil with a steel jacket handles open-loop well water and closed loops alike.
  • Scroll compressor: High-efficiency scroll compressor with internal thermal overload protection, mounted on rubber isolators to cut vibration and noise.
  • Built-in protection: High- and low-pressure switches with a solid-state lockout relay protect the compressor during adverse operating conditions.
  • Reliable refrigerant circuit: TXV metering, filter drier(s) and a pilot-operated reversing valve with a replaceable encapsulated coil.
  • Quiet operation: Closed-cell insulation lines the cabinet to reduce sound transmission into occupied spaces.
  • Service-friendly: Pre-colored thermostat wires and easy-disconnect brackets simplify motor and blower wheel removal.
  • Humidity control: Paired with a thermostat that has humidity control, the fan runs at a lower speed to pull more moisture from the air.
  • Low-GWP refrigerant: Factory charged with R-454B, the A2L replacement for R-410A.

Factory Options

Coldflow offers build-to-order options for the CFF series, including a desuperheater (heat recovery), two-stage compressor, sound package, hot gas bypass, hot gas reheat, waterside economizer, freeze protection, compressor blanket, insulated heat exchanger and marine upgrades. Contact HVAC365 for pricing and lead time on a custom build.

Benefits

  • Lower operating cost: Moving heat to and from water is more efficient than rejecting it to outdoor air, especially on geothermal and well-water systems.
  • No outdoor unit: The complete system installs indoors, keeping equipment out of the weather and off the roof or yard.
  • Year-round comfort: One unit provides both cooling and heating, with a reversing valve to switch modes.
  • Built to last: Stainless steel and cupronickel construction stand up to coastal and high-humidity locations.

Compatibility & Installation

  • Applications: Water loop (boiler/cooling tower), open-loop ground water and closed-loop geothermal systems. Use antifreeze on closed loops that can see low entering fluid temperatures.
  • Cabinet & return: Horizontal cabinet with a right-hand return. Horizontal units suit ceiling plenums, attics and crawl spaces. Confirm the return side against your duct and service access layout before ordering.
  • Electrical: Requires 460V three-phase, 60 Hz service. Size wiring and overcurrent protection to the unit nameplate and local code.
  • Water flow: Provide the rated water flow for the unit and install shutoff valves, a strainer and flexible hose kits to simplify service.
  • Professional installation: Install by a licensed HVAC professional. R-454B is an A2L refrigerant, so follow current installation codes and the manufacturer's instructions.

Frequently Asked Questions

Can this unit be used for geothermal?
Yes. The CFF series is rated for water loop, ground water and ground loop applications, and the cupronickel coil is suited to open-loop well water.

What does "Right Hand Return" mean?
Facing the front (service panel) of the unit, the return air enters from the right side. Pick the return side that matches your duct layout.

What voltage is this model?
The "D" right after the size in the model number means 460V three-phase, 60 Hz. This model is also available in other electrical configurations; search for the same model with a different voltage letter (the letter right after the size) (C = 208/230V 3ph, D = 460V 3ph). This size is not built for single-phase power.

Where is it made?
Coldflow builds its water source heat pumps in Miami, Florida, USA.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Coldflow
Width:
93.25 (in)
Height:
31.00 (in)
Depth:
36.00 (in)
Weight:
770.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Prop 65 Warning:
Yes
Capacity (Tons):
20
Package Type:
Water Source
Configuration:
Horizontal
Refrigerant Type:
R-454B
Electrical Phase:
3-Phase
Return Air / Filter Location:
Right Return
Voltage / Phase:
460V 3-Phase
Electrical Frequency:
60 Hz
Heat Exchanger Material:
Cupronickel
Compressor Type:
Scroll
Product Line:
CFF
Model Number:
CFF240D4-HREFN-X
Nominal Capacity:
20 Ton
Return Air:
Right Hand Return
Electrical Supply:
460V, 3-Phase, 60 Hz
Water Coil:
Coaxial cupronickel with steel jacket
Air Coil:
Copper tubes, aluminum fins
Metering Device:
TXV
Cabinet & Drain Pan:
Stainless steel, insulated
Cooling Capacity (BTU):
248,890
EER | Water Loop:
12.8
Heating BTU | Water Loop:
331,170
COP | Water Loop:
4.6
EER | Ground Water:
18.1
Heating BTU | Ground Water:
256,360
COP | Ground Water:
4.1
EER | Ground Loop:
15.9
Heating BTU | Ground Loop:
177,980
COP | Ground Loop:
3.4
Airflow (CFM):
8000
Flow (GPM):
60
Unit Weight:
750 lb
Shipping Weight:
770 lb
Rated Airflow:
8,000 CFM
Rated Water Flow:
60 GPM
Unit Dimensions (L x W x H):
93.25" x 36" x 31"
Water Loop:
Cooling (Btu/h): 248,890, EER: 12.8, Heating (Btu/h): 331,170, COP: 4.6
Ground Water:
Cooling (Btu/h): 306,060, EER: 18.1, Heating (Btu/h): 256,360, COP: 4.1
Ground Loop:
Cooling (Btu/h): 283,190, EER: 15.9, Heating (Btu/h): 177,980, COP: 3.4
Compressor Stages:
Two Stage (Dual Compressor)
Minimum Circuit Ampacity (MCA):
39.0
Maximum Overcurrent Protection (MOP):
50
Breaker Size (Amps):
50
Compressor RLA / LRA:
13.5 / 123 A each (2 compressors)
Maximum Fuse Size:
50 A
Blower Motor:
2 x 3 HP
Water Coil Pressure Drop:
30 GPM: 3.7 ft (1.6 psi); 40 GPM: 6.2 ft (2.7 psi); 50 GPM: 9.3 ft (4.0 psi); 60 GPM: 12.9 ft (5.6 psi); 75 GPM: 19.2 ft (8.3 psi)
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
5 Years Compressor & 1 Year Parts
Frequently asked questions
What size is the ?
The is a 20 ton unit.
What refrigerant does the use?
It uses R-454B refrigerant.
What power supply does the need?
It requires 460V 3-Phase power.
How much cooling does the provide?
It is rated for 248,890 BTU of cooling.
What warranty comes with the CFF240D4-HREFN-X-RMD?
5 Years Compressor & 1 Year Parts
Who makes the CFF240D4-HREFN-X-RMD?
The CFF240D4-HREFN-X-RMD is made by Coldflow.