MRCOOL 20 kW Electric Heat Kit with Circuit Breaker for Universal Series R-454B Air Handlers 208/230V | UHK20

MRCOOL

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
UHK20
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
UPC:
840255588089
Condition:
New
Width:
15.00 (in)
Height:
10.25 (in)
Depth:
25.63 (in)

Questions about MRCOOL 20 kW Electric Heat Kit with Circuit Breaker for Universal Series R-454B Air Handlers 208/230V | UHK20?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$383.00

  • $9.95 Flat-Rate Shipping
30 in stock • Ships in 3-4 Business Days
Overview

MRCOOL 20 kW Electric Heat Kit with Circuit Breaker for Universal Series R-454B Air Handlers 208/230V | UHK20

MRCOOL 20 kW Electric Heat Kit with Circuit Breaker for Universal Series R-454B Air Handlers 208/230V
Product details

Description

The MRCOOL UHK20 is a 20 kW electric heat kit for Universal Series UAH air handlers on R-454B systems. It adds roughly 68,240 BTU/h of electric heat (calculated from its kW rating) for supplemental heat on the coldest days, emergency heat if the heat pump is down, and heat during defrost.

The kit slides into the air handler cabinet on support rails and plugs into the control board, and it carries its own built-in circuit breaker protection (2 supply circuits). It runs on 208/230V single phase.

Compatibility

MRCOOL approves this kit for these air handlers: UAH18036-O, UAH18048-O, UAH18060-O. Check the air handler model before ordering, since smaller cabinets do not accept the larger kits.

Electrical

Number of Relays: 4. Electrical (Heater Amps / MCA / MOP): Circuit 1: Heater Amps 36.0/40.0, MCA 46.0/53.0, MOP 50.0/60.0; Circuit 2: Heater Amps 36.0/40.0, MCA 46.0/53.0, MOP 50.0/60.0 (208/230V). Minimum Circuit Ampacity (MCA): Circuit 1: 46.0/53.0 A; Circuit 2: 46.0/53.0 A (208V/230V). Maximum Overcurrent Protection (MOP): Circuit 1: 50.0/60.0 A; Circuit 2: 50.0/60.0 A (208V/230V). Number of Supply Circuits: 2.

Key Features

  • Built-in breaker: Circuit breaker protection built into the kit
  • Slide-in design: Installs on rails inside the air handler cabinet
  • Staged heat: Works with W1/W2 heat stages on a 24V thermostat
  • R-454B systems: Made for Universal Series air handlers

Frequently Asked Questions

Which air handlers does it fit?

UAH18036-O, UAH18048-O, UAH18060-O.

How much heat does it add?

20 kW, which works out to about 68,240 BTU/h.

Does it need its own circuit?

Yes. The heat kit is fed from its own 208/230V supply, sized to the MCA and MOP listed above.

Who should install it?

A qualified HVAC technician or electrician, following the air handler wiring diagram and local electrical code.

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
MRCOOL
Width:
15.00 (in)
Height:
10.25 (in)
Depth:
25.63 (in)
Weight:
15.40 LBS
Prop 65 Warning:
Yes
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Category:
Electric Heat Kit
Series:
Universal Series
Heat Kit kW:
20 kW
Heating Output (BTU):
68,240 BTU/h (calculated)
Voltage / Phase:
208/230V 1-Phase
Electrical Phase:
1-Phase
Electrical Frequency:
60 Hz
Circuit Protection:
Built-in circuit breaker
Refrigerant Type:
For R-454B air handlers
Compatible Air Handlers:
UAH18036-O, UAH18048-O, UAH18060-O
Number of Relays:
4
Electrical (Heater Amps / MCA / MOP):
Circuit 1: Heater Amps 36.0/40.0, MCA 46.0/53.0, MOP 50.0/60.0; Circuit 2: Heater Amps 36.0/40.0, MCA 46.0/53.0, MOP 50.0/60.0 (208/230V)
Minimum Circuit Ampacity (MCA):
Circuit 1: 46.0/53.0 A; Circuit 2: 46.0/53.0 A (208V/230V)
Maximum Overcurrent Protection (MOP):
Circuit 1: 50.0/60.0 A; Circuit 2: 50.0/60.0 A (208V/230V)
Number of Supply Circuits:
2
UPC:
840255588089
Heating Capacity (kW):
20
Product Type:
HVAC Accessory
Product Line:
UHK
Kit Family:
UHK electric heat kit for Universal Series air handlers
Compatible Equipment Brand:
MRCOOL
Compatible Equipment:
MRCOOL Universal Series R-454B air handlers
Compatible Units:
UAH18036-O, UAH18048-O, UAH18060-O
Manufacturer Part Number:
UHK20
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Parts & 2 Years Labor
Frequently asked questions
What power supply does the need?
It requires 208/230V 1-Phase power.
What refrigerant does the use?
It uses For R-454B air handlers refrigerant.
What warranty comes with the UHK20?
10 Years Parts & 2 Years Labor
Who makes the UHK20?
The UHK20 is made by MRCOOL.