Description
The MRCOOL MVP-18-HP-C-230A00-O is the 1.5-ton outdoor heat pump unit of the VersaPro 2nd Gen line. Matched with the MVP-18-HP-MUAH-230A00-O air handler it is AHRI certified (Reference No. 216032535) at 18.8 SEER2, 11 EER2 and 9.1 HSPF2, with 18,000 BTU/h of rated cooling and 18,000 BTU/h of heating at 47°F on R-454B refrigerant.
The outdoor unit uses a variable-speed DC inverter compressor that ramps up and down with the load instead of cycling on and off at full power. The coil carries MRCOOL's Gold Fin coating to resist corrosion, and the painted galvanized steel cabinet discharges air out the side, so it fits along a side yard where a tall top-discharge condenser would not.
It is built for the heating and cooling loads of most of the country, and it keeps running efficiently in mild to moderately cold winters, with an electric heat kit available for colder snaps.
Electrical and piping
The unit runs on 208/230V single phase with a 16 A minimum circuit ampacity and 20 A maximum overcurrent protection. It uses a 3/8 in liquid line and 3/4 in suction line, ships charged for 24.6 ft of line set, and supports runs up to 98.4 ft (30 m) with 65.6 ft (20 m) of lift. It measures 31.69 x 12.99 x 21.81 in and weighs 77 lbs.
Replacing just the outdoor unit
The ratings above apply only when this condenser is paired with the MVP-18-HP-MUAH-230A00-O. If you are replacing a failed outdoor unit on an existing VersaPro system, match the model to your air handler before ordering. MRCOOL covers the compressor and parts for 10 years.
Key Features
- Inverter compressor: Variable-speed DC inverter for steady comfort and lower energy use
- R-454B refrigerant: Current low-GWP refrigerant
- Side discharge: Compact cabinet that fits tight side yards
- Corrosion protection: Gold Fin coil coating
Frequently Asked Questions
Which air handler does this condenser match?
The MVP-18-HP-MUAH-230A00-O. That pair is the AHRI-certified combination (No. 216032535).
What size breaker does it need?
MRCOOL lists 16 A minimum circuit ampacity and 20 A maximum overcurrent protection on a 208/230V single-phase circuit.
What line set does it use?
3/8 in liquid and 3/4 in suction, charged for 24.6 ft. Add 0.7 oz of R-454B per additional foot, up to 98.4 ft (30 m).
Does it need a professional installer?
Yes. It must be piped, evacuated and charged by a licensed HVAC contractor. Local codes and efficiency requirements vary, so have your installer confirm the unit for your area.